Noise Propagation in Multipinhole SPECT Calibration

被引:1
|
作者
Vunckx, Kathleen [1 ]
Zhou, Lin [1 ]
Nuyts, Johan [1 ]
机构
[1] Katholieke Univ Leuven, Dept Nucl Med, B-3000 Louvain, Belgium
关键词
GEOMETRICAL CALIBRATION; PINHOLE SPECT; DESIGN;
D O I
10.1109/NSSMIC.2009.5401695
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
It has been shown previously that multipinhole single photon emission computed tomography (SPECT) calibration only requires a two-point source measurement, without knowledge of the distance between them, to uniquely determine the camera geometry. In this work, we studied how this method propagates measurement noise into errors on the estimated calibration parameters, which in turn will degrade the reconstruction image quality. Furthermore, the effect on the calibration and reconstruction accuracy of fixing either the inter-point or the inter-pinhole distance during calibration is assessed. As expected, including information about the distance between the point sources improved the robustness of the calibration against measurement noise. In addition, it was found that similar robustness and even a superior spatial resolution can be obtained by fixing the distance(s) between the pinhole apertures instead of fixing those between the point sources. Finally, optimal two-point source configurations were determined for calibrating our newly-designed 7-pinhole SPECT system for limited field of view mouse imaging while fixing the inter-pinhole distances.
引用
收藏
页码:3166 / 3172
页数:7
相关论文
共 50 条
  • [21] Patient position alters attenuation effects in multipinhole cardiac SPECT
    Timmins, Rachel
    Ruddy, Terrence D.
    Wells, R. Glenn
    MEDICAL PHYSICS, 2015, 42 (03) : 1233 - 1240
  • [22] Study on Analytical System Matrix Constructions for a Stationary Multipinhole SPECT System
    Chang, Shih-Ying
    Tsai, Yu-Jung
    Hsiao, Ing-Tsung
    2011 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2011, : 3680 - 3683
  • [23] Onboard functional and molecular imaging: A design investigation for robotic multipinhole SPECT
    Bowsher, James
    Yan, Susu
    Roper, Justin
    Giles, William
    Yin, Fang-Fang
    MEDICAL PHYSICS, 2014, 41 (01)
  • [24] Analytically based photon scatter modeling for a multipinhole cardiac SPECT camera
    Pourmoghaddas, Amir
    Wells, R. Glenn
    MEDICAL PHYSICS, 2016, 43 (11) : 6098 - 6108
  • [25] MULTIPINHOLE COLLIMATION FOR SUPERHIGH RESOLUTION, SMALL FIELD-OF-VIEW SPECT
    LI, J
    JASZCZAK, RJ
    WANG, H
    COLEMAN, RE
    JOURNAL OF NUCLEAR MEDICINE, 1994, 35 (05) : P27 - P27
  • [26] Single and multipinhole collimator design evaluation method for small animal SPECT
    Vunckx, Kathleen
    Beque, Dirk
    Defrise, Michel
    Nuyts, Johan
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2008, 27 (01) : 36 - 46
  • [27] Performance and clinical trials of a multipinhole nonrotational cardiac SPECT system.
    Kirch, DL
    Koss, JE
    Steele, PP
    Johnson, TK
    JOURNAL OF NUCLEAR MEDICINE, 2000, 41 (05) : 177P - 177P
  • [28] The design and evaluation of optimal multipinhole collimators for a SPECT-MR system
    Rittenbach, Andrew
    Xu, Jingyan
    Liu, Ang
    Hugg, James
    Tsui, Benjamin
    JOURNAL OF NUCLEAR MEDICINE, 2011, 52
  • [29] A Simulation Study of Treatment Verification Using On-Board Multipinhole SPECT
    Yan, S.
    Bowsher, J.
    Giles, W.
    Ren, L.
    Yin, F.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2013, 87 (02): : S707 - S707
  • [30] Simulations of a Multipinhole SPECT Collimator for Clinical Dopamine Transporter (DAT) Imaging
    Konik, Arda
    De Beenhouwer, Jan
    Mukherjee, Joyeeta M.
    Kalluri, Kesava
    Banerjee, Soumyanil
    Zeraatkar, Navid
    Fromme, Timothy
    King, Michael A.
    IEEE TRANSACTIONS ON RADIATION AND PLASMA MEDICAL SCIENCES, 2018, 2 (05) : 444 - 451