A Low-Noise Charge Sensitive Preamplifier for Ge Spectroscopy operating at Cryogenic Temperature in the GERDA Experiment

被引:0
|
作者
Riboldi, Stefano [1 ,2 ]
Zocca, Francesca [1 ,2 ]
Pullia, Alberto [1 ,2 ]
Barnabe-Heider, Marik [4 ]
Budjas, Dusan [4 ]
D'Andragora, Alessio [3 ]
Cattadori, Carla [2 ]
机构
[1] Univ Milan, Dept Phys, I-20133 Milan, Italy
[2] INFN, I-17323 Milan, Italy
[3] INFN, LNGS, Milan, Italy
[4] MPIK, Heidelberg, Germany
关键词
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Front-end electronics for ionizing radiation detectors signal read-out must sometimes operate at cryogenic temperatures. The classical solution based on cold input transistor and subsequent warm electronics is sometimes not suitable due to the physical constraints of the experimental setup, so the entire front-end circuit has to operate at cryogenic temperature. The proposed multi-channel charge sensitive preamplifiers ("CC2") have been tested in the framework of the GERDA experiment (GERmanium Detector Array), in connection to High-Purity Germanium (HPGe) detectors and are able to operate at cryogenic (liquid Nitrogen) temperature. The results obtained during preliminary tests with an encapsulated Germanium detector and subsequently with naked Germanium detectors are all within the specifications of the GERDA experiment for Phase-I.
引用
收藏
页码:1386 / 1388
页数:3
相关论文
共 50 条
  • [1] A Cryogenic Low-noise JFET-CMOS Preamplifier for the HPGe Detectors of GERDA
    Pullia, A.
    Zocca, F.
    Riboldi, S.
    Budjas, D.
    D'Andragora, A.
    Cattadori, C.
    2008 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (2008 NSS/MIC), VOLS 1-9, 2009, : 1331 - +
  • [2] WIDE-BAND LOW-NOISE CHARGE SENSITIVE PREAMPLIFIER
    BLALOCK, TV
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1966, NS13 (03) : 457 - +
  • [3] A low-noise current-sensitive preamplifier VIEC based on a charge-sensitive preamplifier
    Kanno, Ikuo
    Nishikawa, Junichiro
    Onabe, Hideaki
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2023, 1047
  • [4] FAST LOW-NOISE CHARGE PREAMPLIFIER
    KARLOVAC, N
    MAYHUGH, TL
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1977, 24 (01) : 327 - 334
  • [5] LOW-NOISE VOLTAGE-SENSITIVE PREAMPLIFIER OPERATED IN THE KELVIN RANGE FOR CRYOGENIC DETECTORS
    ALESSANDRELLO, A
    CAMIN, DV
    GIULIANI, A
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1989, 36 (01) : 471 - 476
  • [6] Design of an Integrated Low-Noise, Low-Power Charge Sensitive Preamplifier for γ and particle spectroscopy with solid state detectors
    Capra, S.
    Mengoni, D.
    Aliaga, R. J.
    Gadea, A.
    Gonzalez, V.
    Pullia, A.
    2014 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2014,
  • [7] LOW-NOISE PREAMPLIFIER FOR GE (LI) RADIATION DETECTORS
    PANITKIN, YG
    INSTRUMENTS AND EXPERIMENTAL TECHNIQUES-USSR, 1971, 14 (01): : 146 - &
  • [8] Low-noise CMOS Charge Preamplifier for X-ray Spectroscopy Detectors
    Bombelli, L.
    Fiorini, C.
    Frizzi, T.
    Nava, R.
    Greppi, A.
    Longoni, A.
    2010 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD (NSS/MIC), 2010, : 135 - 138
  • [9] Low-Noise Charge Preamplifier for Electrostatic Beam Position Monitoring Sensor at the ELENA Experiment
    Bau, Marco
    Ferrari, Marco
    Ferrari, Vittorio
    Soby, Lars
    Marco-Hernandez, Ricardo
    Pedersen, Flemming
    EUROSENSORS 2015, 2015, 120 : 1229 - 1232
  • [10] A FULLY INTEGRATED LOW-NOISE HEMT CHARGE PREAMPLIFIER
    BERTUCCIO, G
    DEGERONIMO, G
    LONGONI, A
    LAUXTERMANN, S
    RUNGE, K
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1995, 365 (2-3): : 592 - 595