A Low-Noise Charge Sensitive Preamplifier for Ge Spectroscopy operating at Cryogenic Temperature in the GERDA Experiment

被引:0
|
作者
Riboldi, Stefano [1 ,2 ]
Zocca, Francesca [1 ,2 ]
Pullia, Alberto [1 ,2 ]
Barnabe-Heider, Marik [4 ]
Budjas, Dusan [4 ]
D'Andragora, Alessio [3 ]
Cattadori, Carla [2 ]
机构
[1] Univ Milan, Dept Phys, I-20133 Milan, Italy
[2] INFN, I-17323 Milan, Italy
[3] INFN, LNGS, Milan, Italy
[4] MPIK, Heidelberg, Germany
关键词
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Front-end electronics for ionizing radiation detectors signal read-out must sometimes operate at cryogenic temperatures. The classical solution based on cold input transistor and subsequent warm electronics is sometimes not suitable due to the physical constraints of the experimental setup, so the entire front-end circuit has to operate at cryogenic temperature. The proposed multi-channel charge sensitive preamplifiers ("CC2") have been tested in the framework of the GERDA experiment (GERmanium Detector Array), in connection to High-Purity Germanium (HPGe) detectors and are able to operate at cryogenic (liquid Nitrogen) temperature. The results obtained during preliminary tests with an encapsulated Germanium detector and subsequently with naked Germanium detectors are all within the specifications of the GERDA experiment for Phase-I.
引用
收藏
页码:1386 / 1388
页数:3
相关论文
共 50 条
  • [32] A low noise charge sensitive preamplifier with switch control feedback resistance
    Wembe Tafo Evariste
    Su Hong
    Peng Yu
    Wu Ming
    Qian Yi
    NUCLEAR SCIENCE AND TECHNIQUES, 2008, 19 (01) : 39 - 44
  • [33] A low noise charge sensitive preamplifier with switch control feedback resistance
    WEMBE TAFO Evariste
    Nuclear Science and Techniques, 2008, (01) : 39 - 44
  • [34] Experimental performance of a highly-innovative low-noise charge-sensitive preamplifier with integrated range-booster
    Pullia, A.
    Capra, S.
    JOURNAL OF INSTRUMENTATION, 2018, 13
  • [35] A low-noise, wide-band CMOS charge-sensitive preamplifier for use with APD/LSO PET detectors
    Paulus, MJ
    Rochelle, JM
    Andreaco, MS
    Binkley, DM
    1995 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE RECORD, VOLS 1-3, 1996, : 330 - 334
  • [36] Low-noise, wide-band CMOS charge-sensitive preamplifier for use with APD/LSO PET detectors
    Paulus, MJ
    Rochelle, JM
    Andreaco, MS
    Binkley, DM
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1996, 43 (03) : 1666 - 1671
  • [37] Integrated low-noise low-power fast charge-sensitive preamplifier for avalanche photodiodes in JFET-CMOS technology
    Pichler, BJ
    Pimpl, W
    Buttler, W
    Kotoulas, L
    Böning, G
    Rafecas, M
    Lorenz, E
    Ziegler, SI
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2001, 48 (06) : 2370 - 2374
  • [38] An ultra-low noise cryogenic CMOS charge sensitive preamplifier for large volume point-contact HPGe detectors
    Deng, Z.
    He, L.
    Liu, F.
    Liu, Y.
    Li, Y.
    Yue, Q.
    JOURNAL OF INSTRUMENTATION, 2018, 13
  • [39] A low-noise charge-sensitive preamplifier for an X-ray detector of a Nb-based superconducting tunnel junction
    Ukibe, M
    Kishimoto, M
    Katagiri, M
    Kurakado, M
    Nakazawa, M
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1997, 401 (2-3): : 299 - 308