A Low-Noise Charge Sensitive Preamplifier for Ge Spectroscopy operating at Cryogenic Temperature in the GERDA Experiment

被引:0
|
作者
Riboldi, Stefano [1 ,2 ]
Zocca, Francesca [1 ,2 ]
Pullia, Alberto [1 ,2 ]
Barnabe-Heider, Marik [4 ]
Budjas, Dusan [4 ]
D'Andragora, Alessio [3 ]
Cattadori, Carla [2 ]
机构
[1] Univ Milan, Dept Phys, I-20133 Milan, Italy
[2] INFN, I-17323 Milan, Italy
[3] INFN, LNGS, Milan, Italy
[4] MPIK, Heidelberg, Germany
关键词
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Front-end electronics for ionizing radiation detectors signal read-out must sometimes operate at cryogenic temperatures. The classical solution based on cold input transistor and subsequent warm electronics is sometimes not suitable due to the physical constraints of the experimental setup, so the entire front-end circuit has to operate at cryogenic temperature. The proposed multi-channel charge sensitive preamplifiers ("CC2") have been tested in the framework of the GERDA experiment (GERmanium Detector Array), in connection to High-Purity Germanium (HPGe) detectors and are able to operate at cryogenic (liquid Nitrogen) temperature. The results obtained during preliminary tests with an encapsulated Germanium detector and subsequently with naked Germanium detectors are all within the specifications of the GERDA experiment for Phase-I.
引用
收藏
页码:1386 / 1388
页数:3
相关论文
共 50 条
  • [21] A LOW-NOISE CHARGE SENSITIVE PREAMPLIFIER FOR SEMICONDUCTOR DETECTORS USING PARALLELED FIELD-EFFECT-TRANSISTORS
    SMITH, KF
    CLINE, JE
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1966, NS13 (03) : 468 - +
  • [22] CMOS low-noise switched charge sensitive preamplifier for CdTe and CdZnTe X-ray detectors
    Technion-Israel Inst of Technology, Haifa, Israel
    IEEE Trans Nucl Sci, 1 (20-25):
  • [23] CMOS low-noise switched charge sensitive preamplifier for CdTe and CdZnTe X-ray detectors
    Jakobson, CG
    Nemirovsky, Y
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1997, 44 (01) : 20 - 25
  • [24] Dependence of noise temperature on physical temperature for cryogenic low-noise amplifiers
    McCulloch, Mark A.
    Grahn, Jan
    Melhuish, Simon J.
    Nilsson, Per-Ake
    Piccirillo, Lucio
    Schleeh, Joel
    Wadefalk, Niklas
    JOURNAL OF ASTRONOMICAL TELESCOPES INSTRUMENTS AND SYSTEMS, 2017, 3 (01)
  • [25] A fast low noise charge preamplifier for position sensitive detectors
    Beltrán, D
    Perlas, JA
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2002, 73 (08): : 3075 - 3079
  • [26] Development of a Very Low-Noise Cryogenic Preamplifier for Large-Area SiPM Devices
    D'Incecco, Marco
    Galbiati, Cristiano
    Giovanetti, Graham K.
    Korga, George
    Li, Xinran
    Mandarano, Andrea
    Razeto, Alessandro
    Sablone, Davide
    Savarese, Claudio
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2018, 65 (04) : 1005 - 1011
  • [27] Compact Low-Noise Preamplifier for Noise Spectroscopy with Biased Photodiodes in Cargo Inspection Systems
    Benetti, Bob
    Langeveld, Willem G. J.
    HARD X-RAY, GAMMA-RAY, AND NEUTRON DETECTOR PHYSICS XV, 2013, 8852
  • [28] A Low-Noise Broadband Cryogenic Preamplifier Operated in a High-Field Superconducting Magnet
    Mathur, Raman
    Knepper, Ronald W.
    O'Connor, Peter B.
    IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2008, 18 (04) : 1781 - 1789
  • [29] A low noise cryogenic preamplifier for the cosmic microwave background radiation anisotropy experiment
    Oh, ES
    Sharp, EH
    Fixsen, DJ
    Cheng, ES
    Inman, CA
    Silver, C
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2001, 72 (06): : 2735 - 2737
  • [30] USE OF A MONOLITHIC DUAL JFET IN A LOW-COST, LOW-NOISE, CHARGE-SENSITIVE PREAMPLIFIER FOR SEMICONDUCTOR RADIATION DETECTORS
    RAYMOND, DM
    COTTRALL, MF
    PHYSICS IN MEDICINE AND BIOLOGY, 1988, 33 (03): : 367 - 372