A low-noise current-sensitive preamplifier VIEC based on a charge-sensitive preamplifier

被引:0
|
作者
Kanno, Ikuo [1 ]
Nishikawa, Junichiro [1 ]
Onabe, Hideaki [2 ]
机构
[1] Kyoto Univ, Grad Sch Engn, Dept Nucl Engn, Nishikyo, Kyoto 6158530, Japan
[2] Raytech Corp, Utsunomiya, Tochigi 3210904, Japan
关键词
Current preamplifier; Charge preamplifier; Low noise; Dynamic range; X-ray computed tomography;
D O I
10.1016/j.nima.2022.167789
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
A low-noise current-sensitive preamplifier VIEC has been developed based on the circuitry of a charge-sensitive preamplifier. In this paper, the dynamic ranges of the VIEC and a conventional current-sensitive preamplifier are measured and compared. A method to increase the dynamic range of the VIEC is described. Using the VIEC with enhanced dynamic range, a computed tomography measurement is performed for a strongly attenuating phantom comprising a 10-cm-diameter acrylic cylinder with a 3-cm-diameter iron rod in the center.
引用
收藏
页数:6
相关论文
共 50 条
  • [1] A low-noise current-sensitive preamplifier for X-ray computed tomography with applying a charge-sensitive preamplifier
    Kanno, Ikuo
    Onabe, Hideaki
    JOURNAL OF NUCLEAR SCIENCE AND TECHNOLOGY, 2021, 58 (01) : 100 - 106
  • [2] On the noise behaviour of DMILL charge and current-sensitive preamplifier architectures
    Ardelean, J
    Citterio, M
    Hrisoho, A
    Manfredi, PF
    Speziali, V
    Truong, K
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1998, 406 (01): : 127 - 138
  • [3] On the noise behaviour of DMILL charge and current-sensitive preamplifier architectures
    Ardelean, J.
    Citterio, M.
    Hrisoho, A.
    Manfredi, P.F.
    Speziali, V.
    Truong, K.
    Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 1998, 406 (01): : 127 - 138
  • [5] An Integrated Low-Noise Charge-Sensitive Preamplifier with Virtually Unlimited Spectroscopic Dynamic Range
    Pullia, A.
    Zocca, F.
    Capra, S.
    2012 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE RECORD (NSS/MIC), 2012, : 693 - 696
  • [6] A Versatile Low-Noise Wide-Range Charge-Sensitive Preamplifier for HPGe Detectors
    Pullia, A.
    Pascovici, G.
    Ur, C.
    2012 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE RECORD (NSS/MIC), 2012, : 815 - 818
  • [7] LOW NOISE CHARGE-SENSITIVE PREAMPLIFIER EMPLOYING FIELD EFFECT TRANSISTORS
    PODYACHE.VN
    SHATUNOVSKII, RM
    INSTRUMENTS AND EXPERIMENTAL TECHNIQUES-USSR, 1970, (04): : 1042 - +
  • [8] WIDE-BAND LOW-NOISE CHARGE SENSITIVE PREAMPLIFIER
    BLALOCK, TV
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1966, NS13 (03) : 457 - +
  • [9] ON A NEW FAST CHARGE-SENSITIVE PREAMPLIFIER
    QUARANTA, AA
    MARTINI, M
    OTTAVIANI, G
    ZANARINI, G
    NUCLEAR INSTRUMENTS & METHODS, 1965, 32 (02): : 352 - +
  • [10] HYBRID LOW NOISE CHARGE SENSITIVE PREAMPLIFIER
    HAHN, J
    MAYER, R
    NUCLEAR INSTRUMENTS & METHODS, 1964, 29 (02): : 277 - 281