A Critique of Resonance Frequency Analysis and a Novel Method for Quantifying Dental Implant Stability in Vitro

被引:12
|
作者
Khouja, Naseeba
Tai, Wei Che
Shen, I. Y.
Sorensen, John A.
机构
[1] Biomimetics Biomaterials Biophotonics Biomechanics and Technology Laboratory, Department of Restorative Dentistry, School of Dentistry, University of Washington, 1959 NE Pacific St., Seattle, WA
[2] Department of Mechanical Engineering, University of Washington, Seattle, WA
关键词
angular stiffness; dental implant; experimental modal analysis; finite element analysis; natural frequency; stability; STRESS-DISTRIBUTION; POSTERIOR MAXILLA; ARTIFICIAL BONE; DENSITY; OSSEOINTEGRATION; FAILURE;
D O I
10.11607/jomi.7173
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose: This study assessed the ability of resonance frequency measurements to differentiate the stability of implants with different lengths and diameters, and in different densities of bone. Another objective was to identify an alternative parameter capable of quantifying dental implant stability, thus facilitating greater sensitivity for efficacious detection of compromised or failing implants. Materials and Methods: Implants of two different diameters (4 and 5 mm) and six different lengths were individually placed in synthetic bone blocks of three different densities (15, 40/20, and 40 pounds per cubic foot) in combination with two different abutments (short and tall) to evaluate their stability. Resonance frequency measurements were obtained via Osstell ISQ and experimental modal analysis. The resonance frequency measurements were further confirmed via finite element analysis using commercially available software ANSYS. Results: Resonance frequencies measured via Osstell ISQ and experimental modal analysis did not change with respect to the length of the implants. The finite element analysis also confirmed the measured results. Finite element analysis simulations further indicated that angular stiffness at the neck of the implant (ie, the base of the abutment) varied considerably with respect to the implant length and diameter. Moreover, the calculated angular stiffness was independent of the type of abutment used. Conclusion: The results obtained from resonance frequency analyses did not accurately represent dental implant stability. Changes to implant length and diameter did not affect resonance frequencies. In contrast, angular stiffness at the neck of the implant represented a superior index for quantifying dental implant stability. It not only successfully differentiated stability of implants of both varying lengths and diameters, but also produced quantitative data that were independent of the type of abutments used.t
引用
收藏
页码:595 / 603
页数:9
相关论文
共 50 条
  • [41] Measurement of dental implant stability by resonance frequency analysis and damping capacity assessment: Comparison of both techniques in a clinical trial
    Zix, Juergen
    Hug, Stefan
    Kessler-Liechti, Gerda
    Mericske-Stern, Regina
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2008, 23 (03) : 525 - 530
  • [42] Mathematical equations for dental implant stability patterns during the osseointegration period, based on previous resonance frequency analysis studies
    Charatchaiwanna, Attakorn
    Rojsiraphisa, Thaned
    Aunmeungtong, Weerapan
    Reichart, Peter A.
    Khongkhunthian, Pathawee
    CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2019, 21 (05) : 1028 - 1040
  • [43] An Ex Vivo Model in Human Femoral Heads for Histopathological Study and Resonance Frequency Analysis of Dental Implant Primary Stability
    Hernandez-Cortes, Pedro
    Monje, Alberto
    Galindo-Moreno, Pablo
    Catena, Andres
    Ortega-Oller, Inmaculada
    Salas-Perez, Jose
    Mesa, Francisco
    Gomez-Sanchez, Rafael
    Aguilar, Mariano
    Aguilar, David
    O'Valle, Francisco
    BIOMED RESEARCH INTERNATIONAL, 2014, 2014
  • [44] Measurement of mini-implant stability using resonance frequency analysis
    Nienkemper, Manuel
    Wilmes, Benedict
    Panayotidis, Agamemnon
    Pauls, Alexander
    Golubovic, Vladimir
    Schwarz, Frank
    Drescher, Dieter
    ANGLE ORTHODONTIST, 2013, 83 (02) : 230 - 238
  • [45] Influence of the orientation of the Osstell® transducer during measurement of dental implant stability using resonance frequency analysis: A numerical approach
    Capek, Lukas
    Simunek, Antonin
    Slezak, Radovan
    Dzan, Ladislav
    MEDICAL ENGINEERING & PHYSICS, 2009, 31 (07) : 764 - 769
  • [46] Effectiveness of resonance frequency in predicting orthopedic implant strength and stability in an in vitro osseointegration model
    Isaacson, Brad M.
    Vance, Richard E.
    Chou, Teri G. Rosenbaum
    Blocbaum, Roy D.
    Bachus, Kent N.
    Webster, Joseph B.
    JOURNAL OF REHABILITATION RESEARCH AND DEVELOPMENT, 2009, 46 (09): : 1109 - 1120
  • [47] Influence of simulated bone-implant contact and implant diameter on secondary stability: a resonance frequency in vitro study
    Veltri, Mario
    Gonzalez-Martin, Oscar
    Belser, Urs C.
    CLINICAL ORAL IMPLANTS RESEARCH, 2014, 25 (08) : 899 - 904
  • [48] Primary Implant Stability Analysis of Different Dental Implant Connections and Designs-An In Vitro Comparative Study
    Raz, Perry
    Meir, Haya
    Levartovsky, Shifra
    Sebaoun, Alon
    Beitlitum, Ilan
    MATERIALS, 2022, 15 (09)
  • [49] Comparison of implant stability measurements between a resonance frequency analysis device and a modified damping capacity analysis device: an in vitro study
    Lee, Jungwon
    Pyo, Se-Wook
    Cho, Hyun-Jae
    An, Jung-Sub
    Lee, Jae-Hyun
    Koo, Ki-Tae
    Lee, Yong-Moo
    JOURNAL OF PERIODONTAL AND IMPLANT SCIENCE, 2020, 50 (01): : 56 - 66
  • [50] Evaluation of Resonance Frequency and Micromotion to Achieve Implant Stability Using Vibroacoustic Resonance Frequency Analysis: A Mathematical Model
    Khened, Vineet
    Dhok, Kanad
    Pradhan, Mahesh
    Dhatrak, Pankaj
    Journal of Engineering and Science in Medical Diagnostics and Therapy, 2023, 6 (03)