Influence of the orientation of the Osstell® transducer during measurement of dental implant stability using resonance frequency analysis: A numerical approach

被引:20
|
作者
Capek, Lukas [1 ]
Simunek, Antonin [2 ]
Slezak, Radovan [2 ]
Dzan, Ladislav [3 ]
机构
[1] Tech Univ Liberec, Dept Mech Engn, Liberec 46117 1, Czech Republic
[2] Charles Univ Prague, Fac Med Hradec Kralove, Dept Dent, Hradec Kralove 50001, Czech Republic
[3] Reg Hosp Liberec, Dept Maxillofacial Surg, Liberec 46001, Czech Republic
关键词
Resonance frequency analysis; Dental implants; Stability; Finite element analysis; Resonance frequency; Eigenfrequency; DAMPING CAPACITY ASSESSMENT; IN-VITRO; INTERFACE; BEHAVIOR; SURGERY; SITES; MODEL; TIBIA;
D O I
10.1016/j.medengphy.2009.02.003
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Stability of dental implants is measured by means of the Osstell (R) device using a method of resonance frequency analysis. The aim of the study was to evaluate the role of direction-dependence of the Osstell (R) transducer. For this purpose, a set of parametrical finite element analyses has been used. When rotating the transducer around the vertical axis the crucial phenomenon is the change in behavior of the system, which occurs in positions between 30 degrees and 80 degrees to the long axis of the alveolar crest. It seems from the presented results that, when measuring approximately perpendicularly to this long axis, the deviation from the ideal perpendicular position must not exceed 30 degrees. In this case, the first resonance frequency is recorded. When measuring in the approximately parallel position to the long axis of the alveolar crest, the second resonance frequency is recorded. The deviation from the ideal parallel position must not exceed 10 degrees. These values are not comparable with the previous ones. (C) 2009 IPEM. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:764 / 769
页数:6
相关论文
共 50 条
  • [1] In vitro comparative analysis of two resonance frequency measurement devices: Osstell implant stability coefficient and Penguin resonance frequency analysis
    Herrero-Climent, Mariano
    Falcao, Artur
    Lopez-Jarana, Paula
    Diaz-Castro, Carmen M.
    Rios-Carrasco, Blanca
    Vicente Rios-Santos, Jose
    CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2019, 21 (06) : 1124 - 1131
  • [2] Reliability of the Osstell Implant Stability Quotient and Penguin Resonance Frequency Analysis to Evaluate Implant Stability
    Buyukguclu, Gul
    Ozkurt-Kayahan, Zeynep
    Kazazoglu, Ender
    IMPLANT DENTISTRY, 2018, 27 (04) : 429 - 433
  • [3] Measurement of dental implant stability by resonance frequency analysis: A review of the literature
    Pilar Quesada-Garcia, Ma
    Prados-Sanchez, Estrella
    Victoria Olmedo-Gaya, Ma
    Munoz-Soto, Esther
    Paloma Gonzalez-Rodriguez, Ma
    Vallecillo-Capilla, Manuel
    MEDICINA ORAL PATOLOGIA ORAL Y CIRUGIA BUCAL, 2009, 14 (10): : E538 - E546
  • [4] Resonance frequency analysis of dental implant stability during the healing period
    Boronat Lopez, Araceli
    Balaguer Martinez, Jose
    Lamas Pelayo, Joana
    Carrillo Garcia, Celia
    Penarrocha Diago, Miguel
    MEDICINA ORAL PATOLOGIA ORAL Y CIRUGIA BUCAL, 2008, 13 (04): : E244 - E247
  • [5] A numerical approach of estimating dental implant healing process using resonance frequency analysis (RFA)
    Harirforoush, Reza
    Arzanpour, Siamak
    ASME 2011 International Mechanical Engineering Congress and Exposition, IMECE 2011, 2011, 2 : 679 - 684
  • [6] A NUMERICAL APPROACH OF ESTIMATING DENTAL IMPLANT HEALING PROCESS USING RESONANCE FREQUENCY ANALYSIS (RFA)
    Harirforoush, Reza
    Arzanpour, Siamak
    PROCEEDINGS OF THE ASME INTERNATIONAL MECHANICAL ENGINEERING CONGRESS AND EXPOSITION 2011, VOL 2, 2012, : 679 - 684
  • [7] Resonance frequency assessment of dental implant stability with various bone qualities: a numerical approach
    Huang, HM
    Lee, SY
    Yeh, CY
    Lin, CT
    CLINICAL ORAL IMPLANTS RESEARCH, 2002, 13 (01) : 65 - 74
  • [8] Measurement of mini-implant stability using resonance frequency analysis
    Nienkemper, Manuel
    Wilmes, Benedict
    Panayotidis, Agamemnon
    Pauls, Alexander
    Golubovic, Vladimir
    Schwarz, Frank
    Drescher, Dieter
    ANGLE ORTHODONTIST, 2013, 83 (02) : 230 - 238
  • [9] Reliable method for the in vitro assessment of dental implant stability.: A comparison study of damping capacity measurement with the periotest instrument and resonance frequency analysis with the osstell instrument.
    Lachmann, S.
    Jaeger, B.
    Gomez-Roman, G.
    Axmann, D.
    Weber, H.
    JOURNAL OF DENTAL RESEARCH, 2003, 82 : B174 - B174
  • [10] Effects on the torsional vibration behavior in the investigation of dental implant osseointegration using resonance frequency analysis: a numerical approach
    Zhai, Min
    Li, Bing
    Li, Dehua
    MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2017, 55 (09) : 1649 - 1658