A Critique of Resonance Frequency Analysis and a Novel Method for Quantifying Dental Implant Stability in Vitro

被引:12
|
作者
Khouja, Naseeba
Tai, Wei Che
Shen, I. Y.
Sorensen, John A.
机构
[1] Biomimetics Biomaterials Biophotonics Biomechanics and Technology Laboratory, Department of Restorative Dentistry, School of Dentistry, University of Washington, 1959 NE Pacific St., Seattle, WA
[2] Department of Mechanical Engineering, University of Washington, Seattle, WA
关键词
angular stiffness; dental implant; experimental modal analysis; finite element analysis; natural frequency; stability; STRESS-DISTRIBUTION; POSTERIOR MAXILLA; ARTIFICIAL BONE; DENSITY; OSSEOINTEGRATION; FAILURE;
D O I
10.11607/jomi.7173
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose: This study assessed the ability of resonance frequency measurements to differentiate the stability of implants with different lengths and diameters, and in different densities of bone. Another objective was to identify an alternative parameter capable of quantifying dental implant stability, thus facilitating greater sensitivity for efficacious detection of compromised or failing implants. Materials and Methods: Implants of two different diameters (4 and 5 mm) and six different lengths were individually placed in synthetic bone blocks of three different densities (15, 40/20, and 40 pounds per cubic foot) in combination with two different abutments (short and tall) to evaluate their stability. Resonance frequency measurements were obtained via Osstell ISQ and experimental modal analysis. The resonance frequency measurements were further confirmed via finite element analysis using commercially available software ANSYS. Results: Resonance frequencies measured via Osstell ISQ and experimental modal analysis did not change with respect to the length of the implants. The finite element analysis also confirmed the measured results. Finite element analysis simulations further indicated that angular stiffness at the neck of the implant (ie, the base of the abutment) varied considerably with respect to the implant length and diameter. Moreover, the calculated angular stiffness was independent of the type of abutment used. Conclusion: The results obtained from resonance frequency analyses did not accurately represent dental implant stability. Changes to implant length and diameter did not affect resonance frequencies. In contrast, angular stiffness at the neck of the implant represented a superior index for quantifying dental implant stability. It not only successfully differentiated stability of implants of both varying lengths and diameters, but also produced quantitative data that were independent of the type of abutments used.t
引用
收藏
页码:595 / 603
页数:9
相关论文
共 50 条
  • [21] Relevance of resonance frequency analysis to evaluate dental implant stability: simulation and histomorphometrical animal experiments
    Ito, Yoshihiro
    Sato, Daisuke
    Yoneda, Satoshi
    Ito, Daisuke
    Kondo, Hisatomo
    Kasugai, Shohei
    CLINICAL ORAL IMPLANTS RESEARCH, 2008, 19 (01) : 9 - 14
  • [22] Acoustic resonance frequency analysis for evaluating prosthetic screw stability in splinted implant-supported fixed dental prostheses: An in vitro study
    Guo, Jiaer
    Wang, Xiaolu
    Liu, Zhixin
    Zhou, Jianying
    Wang, Lin
    JOURNAL OF PROSTHETIC DENTISTRY, 2025, 133 (02):
  • [23] Resonance Frequency Analysis in Assessing Implant Stability: A Retrospective Analysis
    Chen, Maggie Hsiao-Mei
    Lyons, Karl
    Tawse-Smith, Andrew
    Ma, Sunyoung
    INTERNATIONAL JOURNAL OF PROSTHODONTICS, 2019, 32 (04) : 317 - 326
  • [24] The effects of implant angulation on the resonance frequency of a dental implant
    Harirforoush, R.
    Arzanpour, S.
    Chehroudi, B.
    MEDICAL ENGINEERING & PHYSICS, 2014, 36 (08) : 1024 - 1032
  • [25] Reliable method for the in vitro assessment of dental implant stability.: A comparison study of damping capacity measurement with the periotest instrument and resonance frequency analysis with the osstell instrument.
    Lachmann, S.
    Jaeger, B.
    Gomez-Roman, G.
    Axmann, D.
    Weber, H.
    JOURNAL OF DENTAL RESEARCH, 2003, 82 : B174 - B174
  • [26] Efficiency Of Customized Connectors In Evaluatingmini Implant Stability Using Resonance Frequency Analysis - An In Vitro Study
    Padmavati
    Keerthana, S. Vaibava
    Saravanan, B.
    INTERNATIONAL JOURNAL OF LIFE SCIENCE AND PHARMA RESEARCH, 2021, : 133 - 138
  • [27] An examination of immediately loaded dental implant stability in the diabetic patient using resonance frequency analysis (RFA)
    Balshi, Stephen F.
    Wolfinger, Glenn J.
    Balshi, Thomas J.
    QUINTESSENCE INTERNATIONAL, 2007, 38 (04): : 271 - 279
  • [28] ASSESSMENT OF IN VITRO DENTAL IMPLANT PRIMARY STABILITY USING AN ULTRASONIC METHOD
    Vayron, Romain
    Mathieu, Vincent
    Michel, Adrien
    Haiat, Guillaume
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2014, 40 (12): : 2885 - 2894
  • [29] Reliability of the Osstell Implant Stability Quotient and Penguin Resonance Frequency Analysis to Evaluate Implant Stability
    Buyukguclu, Gul
    Ozkurt-Kayahan, Zeynep
    Kazazoglu, Ender
    IMPLANT DENTISTRY, 2018, 27 (04) : 429 - 433
  • [30] Measurement of Primary and Secondary Stability of Dental Implants by Resonance Frequency Analysis Method in Mandible
    Shokri, Mehran
    Daraeighadikolaei, Arash
    INTERNATIONAL JOURNAL OF DENTISTRY, 2013, 2013