Resonance Frequency Analysis in Assessing Implant Stability: A Retrospective Analysis

被引:14
|
作者
Chen, Maggie Hsiao-Mei [1 ]
Lyons, Karl [1 ]
Tawse-Smith, Andrew [1 ]
Ma, Sunyoung [1 ]
机构
[1] Univ Otago, Fac Dent, Sir John Walsh Res Inst, POB 56, Dunedin, New Zealand
关键词
DAMPING CAPACITY ASSESSMENT; OSSEOINTEGRATED ORAL IMPLANTS; IMMEDIATELY LOADED IMPLANTS; BONE LEVEL CHANGES; DENTAL IMPLANTS; IN-VITRO; ENDOSSEOUS IMPLANTS; FAILURE RISK; FOLLOW-UP; QUALITY;
D O I
10.11607/ijp.6057
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose: To retrospectively assess implant stability quotient (ISQ) values in patients who were followed up between 1998 and 2014 and to evaluate any correlations between ISQ and clinical parameters, such as change in marginal bone level (MBL). Materials and Methods: A total of 173 participants (65 men and 108 women; age range 21 to 85 years) and 383 implants were included. Implant location, MBL, and ISQ were recorded at surgery and at various recall times for statistical analysis. Mixed-model analysis was applied to evaluate the impact of clinical and demographic variables (time, implant location, patient gender) on ISQ and the correlation between ISQ and MBL. The level of significance was set at P < .05. Results: Of the 21 failed implants, 20 failed within 1 year of functional loading, resulting in a 10-year cumulative implant survival estimate of 95%. The failed implants had lower ISQs at surgery (52.3 +/- 7.03) and baseline (52.5 +/- 4.20) when compared to surviving implants (63.0 +/- 10.74 at surgery and 62.3 +/- 8.30 at baseline), and the difference was statistically significant at surgery (P < .05). The mean ISQs generally increased over time, but there were various patterns of changes between implants when grouped according to patient gender and implant location. There was no statistically significant correlation between the changes in ISQ and MBL (P = .211), despite an inverse relationship. Conclusion: Low initial ISQ values may help to identify implants at higher risk of failure. There may be various patterns of change over time in addition to an overall increase in ISQ values. Both similar and contradictory findings were found when compared to earlier literature, and a correlation between resonance frequency analysis and MBL change could not be identified. Despite limitations, the present study provides an overview of the clinical performance of RFA based on long-term clinical data.
引用
收藏
页码:317 / 326
页数:10
相关论文
共 50 条
  • [1] Mapping implant stability by resonance frequency analysis
    Meredith, N
    Rasmussen, L
    Sennerby, L
    Alleyne, D
    MEDICAL SCIENCE RESEARCH, 1996, 24 (03): : 191 - 193
  • [2] Resonance frequency analysis of miniscrew implant stability
    Tseng, Yu-Chuan
    Pan, Chin-Yun
    Liu, Pao-Hsin
    Yang, Yi-Hsin
    Chang, Hong-Po
    Chen, Chun-Ming
    JOURNAL OF ORAL SCIENCE, 2018, 60 (01) : 64 - 69
  • [3] Clinical Significance of the Use of Resonance Frequency Analysis in Assessing Implant Stability: A Systematic Review
    Chen, Maggie Hsiao-Mei
    Lyons, Karl M.
    Tawse-Smith, Andrew
    Ma, Sunyoung
    INTERNATIONAL JOURNAL OF PROSTHODONTICS, 2019, 32 (01) : 51 - +
  • [4] The application of resonance frequency analysis to map implant stability.
    Meredith, N
    Rasmussen, L
    Sennerby, L
    JOURNAL OF DENTAL RESEARCH, 1996, 75 : 1324 - 1324
  • [5] Reliability of the Osstell Implant Stability Quotient and Penguin Resonance Frequency Analysis to Evaluate Implant Stability
    Buyukguclu, Gul
    Ozkurt-Kayahan, Zeynep
    Kazazoglu, Ender
    IMPLANT DENTISTRY, 2018, 27 (04) : 429 - 433
  • [6] Measurement of dental implant stability by resonance frequency analysis: A review of the literature
    Pilar Quesada-Garcia, Ma
    Prados-Sanchez, Estrella
    Victoria Olmedo-Gaya, Ma
    Munoz-Soto, Esther
    Paloma Gonzalez-Rodriguez, Ma
    Vallecillo-Capilla, Manuel
    MEDICINA ORAL PATOLOGIA ORAL Y CIRUGIA BUCAL, 2009, 14 (10): : E538 - E546
  • [7] Resonance frequency analysis of dental implant stability during the healing period
    Boronat Lopez, Araceli
    Balaguer Martinez, Jose
    Lamas Pelayo, Joana
    Carrillo Garcia, Celia
    Penarrocha Diago, Miguel
    MEDICINA ORAL PATOLOGIA ORAL Y CIRUGIA BUCAL, 2008, 13 (04): : E244 - E247
  • [8] Measurement of mini-implant stability using resonance frequency analysis
    Nienkemper, Manuel
    Wilmes, Benedict
    Panayotidis, Agamemnon
    Pauls, Alexander
    Golubovic, Vladimir
    Schwarz, Frank
    Drescher, Dieter
    ANGLE ORTHODONTIST, 2013, 83 (02) : 230 - 238
  • [9] In vitro comparative analysis of two resonance frequency measurement devices: Osstell implant stability coefficient and Penguin resonance frequency analysis
    Herrero-Climent, Mariano
    Falcao, Artur
    Lopez-Jarana, Paula
    Diaz-Castro, Carmen M.
    Rios-Carrasco, Blanca
    Vicente Rios-Santos, Jose
    CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2019, 21 (06) : 1124 - 1131
  • [10] A simple mathematical model for the resonance frequency analysis of dental implant stability: Implant clamping quotient
    Argatov, Ivan
    Iantchenko, Alexei
    MECHANICS RESEARCH COMMUNICATIONS, 2019, 95 : 67 - 70