Background sensitivity studies for GEM based detectors using a Geant4 simulation

被引:0
|
作者
Vai, Ilaria [1 ,2 ]
机构
[1] Univ Pavia, Dipartimento Fis, Pavia, Italy
[2] Ist Nazl Fis Nucl, Sez Pavia, Pavia, Italy
关键词
D O I
10.1051/epjconf/201921402045
中图分类号
TP18 [人工智能理论];
学科分类号
081104 ; 0812 ; 0835 ; 1405 ;
摘要
Triple-GEM detectors were selected by the CMS Collaboration for instrumenting the high ri region of the muon system. This region is characterized by a huge radiation background, mainly composed by neutrons and photons. In this context, a discharge probability test was performed in 2017 at the CHARM facility at CERN, to study the operation of the detector in an environment similar to the one of the CMS muon system. A Geant4 simulation was developed in parallel to the actual test, in order to evaluate the behaviour of the detector. This paper will present this simulation, from the detector geometry implementation to the results obtained in terms of sensitivity and energy deposited into the gas gaps.
引用
收藏
页数:8
相关论文
共 50 条
  • [31] Geant4 simulation of a Triple-GEM detector exposed to the CHARM field at CERN
    Vai, I
    2018 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE PROCEEDINGS (NSS/MIC), 2018,
  • [32] Pulse shape simulations for organic scintillation detectors using Geant4
    Holroyd, Caroline
    Aspinall, Michael
    Deakin, Tom
    ANIMMA 2021 - ADVANCEMENTS IN NUCLEAR INSTRUMENTATION MEASUREMENT METHODS AND THEIR APPLICATIONS, 2021, 253
  • [33] Photon energy absorption coefficients for nuclear track detectors using Geant4 Monte Carlo simulation
    Singh, Vishwanath P.
    Medhat, M. E.
    Badiger, N. M.
    RADIATION PHYSICS AND CHEMISTRY, 2015, 106 : 83 - 87
  • [34] GEANT4 as a simulation framework in μSR
    Shiroka, T.
    Prokscha, T.
    Morenzoni, E.
    Sedlak, K.
    PHYSICA B-CONDENSED MATTER, 2009, 404 (5-7) : 966 - 969
  • [35] Signal pulse emulation for scintillation detectors using Geant4 Monte Carlo with light tracking simulation
    Ogawara, R.
    Ishikawa, M.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2016, 87 (07):
  • [36] Simulation of the RIBRAS Facility with GEANT4
    L. E. Tamayose
    J. C. Zamora
    G. F. Fortino
    D. Flechas
    Brazilian Journal of Physics, 2022, 52
  • [37] Geant4 simulation of the ABALONE photosensor
    Pieramico, G.
    Biondi, R.
    D'andrea, V
    Ferella, A. D.
    Mahlstedt, J.
    NUOVO CIMENTO C-COLLOQUIA AND COMMUNICATIONS IN PHYSICS, 2022, 45 (01):
  • [38] Industrial gamma computed tomography using high aspect ratio scintillator detectors (A Geant4 simulation)
    Askari, Mojtaba
    Taheri, Ali
    Iarijani, Majid Mojtahedzadeh
    Movafeghi, Amir
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2019, 923 : 109 - 117
  • [39] Hadronic shower simulation with GEANT4
    Wellisch, HP
    PROCEEDINGS OF THE SEVENTH INTERNATIONAL CONFERENCE ON CALORIMETRY IN HIGH ENERGY PHYSICS, 1998, : 522 - 529
  • [40] Simulation of dark bremsstrahlung in GEANT4
    Eichlersmith, Tom
    Mans, Jeremiah
    Moreno, Omar
    Muse, Joseph
    Revering, Michael
    Toro, Natalia
    COMPUTER PHYSICS COMMUNICATIONS, 2023, 287