Signal pulse emulation for scintillation detectors using Geant4 Monte Carlo with light tracking simulation

被引:11
|
作者
Ogawara, R. [1 ]
Ishikawa, M. [2 ]
机构
[1] Hokkaido Univ, Grad Sch Med, Dept Med Phys & Engn, Kita Ku, Kita 15 Nishi 7, Sapporo, Hokkaido, Japan
[2] Hokkaido Univ, Grad Sch Hlth Sci, Kita Ku, Kita 12 Nishi 5, Sapporo, Hokkaido, Japan
来源
REVIEW OF SCIENTIFIC INSTRUMENTS | 2016年 / 87卷 / 07期
关键词
SHAPE-DISCRIMINATION; SINGLE-CRYSTALS; IDENTIFICATION; DEPTH;
D O I
10.1063/1.4959186
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The anode pulse of a photomultiplier tube (PMT) coupled with a scintillator is used for pulse shape discrimination (PSD) analysis. We have developed a novel emulation technique for the PMT anode pulse based on optical photon transport and a PMT response function. The photon transport was calculated using Geant4 Monte Carlo code and the response function with a BC408 organic scintillator. The obtained percentage RMS value of the difference between the measured and simulated pulse with suitable scintillation properties using GSO:Ce (0.4, 1.0, 1.5 mol%), LaBr3:Ce and BGO scintillators were 2.41%, 2.58%, 2.16%, 2.01%, and 3.32%, respectively. The proposed technique demonstrates high reproducibility of the measured pulse and can be applied to simulation studies of various radiation measurements. (C) 2016 Author(s).
引用
收藏
页数:8
相关论文
共 50 条
  • [1] Pulse shape simulations for organic scintillation detectors using Geant4
    Holroyd, Caroline
    Aspinall, Michael
    Deakin, Tom
    ANIMMA 2021 - ADVANCEMENTS IN NUCLEAR INSTRUMENTATION MEASUREMENT METHODS AND THEIR APPLICATIONS, 2021, 253
  • [2] Monte Carlo simulation of the ELIMED beamline using Geant4
    Pipek, J.
    Romano, F.
    Milluzzo, G.
    Cirrone, G. A. P.
    Cuttone, G.
    Amico, A. G.
    Margarone, D.
    Larosa, G.
    Leanza, R.
    Petringa, G.
    Schillaci, F.
    Scuderi, V.
    JOURNAL OF INSTRUMENTATION, 2017, 12
  • [3] Photon energy absorption coefficients for nuclear track detectors using Geant4 Monte Carlo simulation
    Singh, Vishwanath P.
    Medhat, M. E.
    Badiger, N. M.
    RADIATION PHYSICS AND CHEMISTRY, 2015, 106 : 83 - 87
  • [4] A framework for Monte Carlo simulation calculations in GEANT4
    Walker, B.
    Figgins, J.
    Comfort, J. R.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2006, 568 (02): : 889 - 895
  • [5] A Comparison of GEANT4 and DETECT2000 for the Simulation of Light Transport in Scintillation Detectors
    Blackston, Matthew A.
    Habte, Frezghi
    Hausladen, Paul A.
    2008 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (2008 NSS/MIC), VOLS 1-9, 2009, : 4261 - 4264
  • [6] The Geant4 Virtual Monte Carlo
    Hrivnacova, I.
    INTERNATIONAL CONFERENCE ON COMPUTING IN HIGH ENERGY AND NUCLEAR PHYSICS 2012 (CHEP2012), PTS 1-6, 2012, 396
  • [7] GATE/Geant4 as a Monte Carlo simulation toolkit for light ion beam dosimetry
    Bolsa-Ferruz, M.
    Palmans, H.
    Carlino, A.
    Stock, M.
    Traneus, E.
    Grevillot, L.
    RADIOTHERAPY AND ONCOLOGY, 2020, 152 : S727 - S728
  • [8] Monte Carlo simulation of scintillation behavior of zinc oxide under X-ray illumination using GEANT4
    Taheri, Ali
    Saramad, Shahyar
    Setayeshi, Saeed
    RADIATION EFFECTS AND DEFECTS IN SOLIDS, 2013, 168 (02): : 153 - 162
  • [9] Determination of Position Resolution for LYSO Scintillation Crystals Using Geant4 Monte Carlo Code
    Yahya, M. F. O.
    Kocak, F.
    ADVANCES IN HIGH ENERGY PHYSICS, 2021, 2021 (2021)
  • [10] Simulation of LHCb RICH detectors using GEANT4
    Easo, S
    Belyaev, I
    Corti, G
    Jones, C
    Papanestis, J
    Pokorski, W
    Ranjard, F
    Robbe, P
    2004 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-7, 2004, : 2182 - 2185