Signal pulse emulation for scintillation detectors using Geant4 Monte Carlo with light tracking simulation

被引:11
|
作者
Ogawara, R. [1 ]
Ishikawa, M. [2 ]
机构
[1] Hokkaido Univ, Grad Sch Med, Dept Med Phys & Engn, Kita Ku, Kita 15 Nishi 7, Sapporo, Hokkaido, Japan
[2] Hokkaido Univ, Grad Sch Hlth Sci, Kita Ku, Kita 12 Nishi 5, Sapporo, Hokkaido, Japan
来源
REVIEW OF SCIENTIFIC INSTRUMENTS | 2016年 / 87卷 / 07期
关键词
SHAPE-DISCRIMINATION; SINGLE-CRYSTALS; IDENTIFICATION; DEPTH;
D O I
10.1063/1.4959186
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The anode pulse of a photomultiplier tube (PMT) coupled with a scintillator is used for pulse shape discrimination (PSD) analysis. We have developed a novel emulation technique for the PMT anode pulse based on optical photon transport and a PMT response function. The photon transport was calculated using Geant4 Monte Carlo code and the response function with a BC408 organic scintillator. The obtained percentage RMS value of the difference between the measured and simulated pulse with suitable scintillation properties using GSO:Ce (0.4, 1.0, 1.5 mol%), LaBr3:Ce and BGO scintillators were 2.41%, 2.58%, 2.16%, 2.01%, and 3.32%, respectively. The proposed technique demonstrates high reproducibility of the measured pulse and can be applied to simulation studies of various radiation measurements. (C) 2016 Author(s).
引用
收藏
页数:8
相关论文
共 50 条
  • [31] GePEToS: A Geant4 Monte Carlo simulation package for positron emission tomography
    Jan, S
    Collot, J
    Gallin-Martel, ML
    Martin, P
    Mayet, F
    Tournefier, E
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2005, 52 (01) : 102 - 106
  • [32] Proton transport in water and DNA components: A Geant4 Monte Carlo simulation
    Champion, C.
    Incerti, S.
    Tran, H. N.
    Karamitros, M.
    Shin, J. I.
    Lee, S. B.
    Lekadir, H.
    Bernal, M.
    Francis, Z.
    Ivanchenko, V.
    Fojon, O. A.
    Hanssen, J.
    Rivarola, R. D.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2013, 306 : 165 - 168
  • [33] Geant4 Monte Carlo simulations for the LPCTrap setup
    Rodriguez, D.
    Ban, G.
    Durand, D.
    Duval, F.
    Flechard, X.
    Lienard, E.
    Mauger, F.
    Mery, A.
    Naviliat-Cuncic, O.
    Thomas, J. -C.
    Velten, Ph.
    EUROPEAN PHYSICAL JOURNAL A, 2009, 42 (03): : 397 - 400
  • [34] Geant4 Monte Carlo simulations for the LPCTrap setup
    D. Rodríguez
    G. Ban
    D. Durand
    F. Duval
    X. Fléchard
    E. Liénard
    F. Mauger
    A. Méry
    O. Naviliat-Cuncic
    J. -C. Thomas
    Ph. Velten
    The European Physical Journal A, 2009, 42 : 397 - 400
  • [35] Monte Carlo simulations in proton dosimetry with Geant4
    Moravek, Z
    Bogner, L
    RADIOTHERAPY AND ONCOLOGY, 2005, 76 : S62 - S62
  • [36] GEANT4 simulation of the response of a liquid scintillation counter
    Hurtado, S.
    JOURNAL OF INSTRUMENTATION, 2017, 12
  • [37] Monte Carlo Simulation of a 18 MV Medical Linac Photon Beam Using GATE/GEANT4
    M. Fiak
    A. Fathi
    J. Inchaouh
    A. Khouaja
    A. Benider
    M. Krim
    N. Harakat
    Z. Housni
    M. L. Bouhssa
    M. Mouadil
    Y. Elabssaoui
    O. Jdair
    Moscow University Physics Bulletin, 2021, 76 : 15 - 21
  • [38] Simulation response of single gap RPC studies for neutrons using GEANT4 Monte Carlo codes
    Jamil, M.
    Rhee, J. T.
    Jeon, Y. J.
    RADIATION MEASUREMENTS, 2008, 43 (9-10) : 1554 - 1557
  • [39] Monte Carlo simulation of NovalisTx linear accelerator using GATE/Geant4 code for dosimetry analysis
    Fathi, Ahmed
    Khobbaizi, Youness
    Nabil, Sanaa
    Ardouz, Anas
    Hasnaoui, Abdellatif
    Sbiaai, Khalid
    MATERIALS TODAY-PROCEEDINGS, 2022, 66 : 466 - 472
  • [40] Erratum to: Simulation of Electron Trajectories in the Multicusp Ion Source Using Geant4 Monte Carlo Code
    Fatemeh Khodadadi Azadboni
    Mahmood Sedaghatizade
    Journal of Fusion Energy, 2010, 29 : 305 - 305