Background sensitivity studies for GEM based detectors using a Geant4 simulation

被引:0
|
作者
Vai, Ilaria [1 ,2 ]
机构
[1] Univ Pavia, Dipartimento Fis, Pavia, Italy
[2] Ist Nazl Fis Nucl, Sez Pavia, Pavia, Italy
关键词
D O I
10.1051/epjconf/201921402045
中图分类号
TP18 [人工智能理论];
学科分类号
081104 ; 0812 ; 0835 ; 1405 ;
摘要
Triple-GEM detectors were selected by the CMS Collaboration for instrumenting the high ri region of the muon system. This region is characterized by a huge radiation background, mainly composed by neutrons and photons. In this context, a discharge probability test was performed in 2017 at the CHARM facility at CERN, to study the operation of the detector in an environment similar to the one of the CMS muon system. A Geant4 simulation was developed in parallel to the actual test, in order to evaluate the behaviour of the detector. This paper will present this simulation, from the detector geometry implementation to the results obtained in terms of sensitivity and energy deposited into the gas gaps.
引用
收藏
页数:8
相关论文
共 50 条
  • [41] Electron backscattering simulation in Geant4
    Dondero, Paolo
    Mantero, Alfonso
    Ivanchencko, Vladimir
    Lotti, Simone
    Mineo, Teresa
    Fioretti, Valentina
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2018, 425 : 18 - 25
  • [42] Simulation of 4π Ge spectrometer by Geant4
    Goto, J
    Sugawara, M
    Oshima, M
    Toh, Y
    Kimura, A
    Osa, A
    Koizumi, M
    Mizumoto, A
    Ohsaki, T
    Igashira, A
    Harada, H
    Nagai, Y
    INTERNATIONAL CONFERENCE ON NUCLEAR DATA FOR SCIENCE AND TECHNOLOGY, PTS 1 AND 2, 2005, 769 : 788 - 791
  • [43] Geant4 portlet: Monte-Carlo simulation with Geant4 on bwGRiD over a browser-based interface
    Zyl, A.
    Hesser, J.
    Mosch, C.
    Alnewaini, Z.
    STRAHLENTHERAPIE UND ONKOLOGIE, 2012, 188 : 168 - 169
  • [44] Introduction to the Geant4 Simulation toolkit
    Guatelli, S.
    Cutajar, D.
    Oborn, B.
    Rosenfeld, A. B.
    CONCEPTS AND TRENDS IN MEDICAL RADIATION DOSIMETRY, 2011, 1345 : 303 - 322
  • [45] Simulation of the RIBRAS Facility with GEANT4
    Tamayose, L. E.
    Zamora, J. C.
    Fortino, G. F.
    Flechas, D.
    BRAZILIAN JOURNAL OF PHYSICS, 2022, 52 (03)
  • [46] Investigation of cosmic-ray and Solar Energetic Particle background of STIX using GEANT4 simulation
    Barylak, Jaromir
    Barylak, Aleksandra
    Mrozek, Tomasz
    Steslicki, Marek
    Podgorski, Piotr
    PHOTONICS APPLICATIONS IN ASTRONOMY, COMMUNICATIONS, INDUSTRY, AND HIGH-ENERGY PHYSICS EXPERIMENTS 2018, 2018, 10808
  • [47] Investigation of cosmic-ray induced background of Germanium gamma spectrometer using GEANT4 simulation
    Nguyen Quoc Hung
    Vo Hong Hai
    Nomachi, Masaharu
    APPLIED RADIATION AND ISOTOPES, 2017, 121 : 87 - 90
  • [48] Simulation study of Fast Neutron Radiography using GEANT4
    Bishnoi, S.
    Thomas, R. G.
    Sarkar, P. S.
    Datar, V. M.
    Sinha, A.
    JOURNAL OF INSTRUMENTATION, 2015, 10
  • [49] Study of proton computed tomography using GEANT4 simulation
    Aso, Tsukasa
    Fujisaka, Katsuhiko
    2007 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-11, 2007, : 876 - 879
  • [50] Three Dimensional Simulation of ITER Machine by Using Geant4
    Mohammad Mehdi Nasseri
    Journal of Fusion Energy, 2016, 35 : 621 - 625