Three-dimensional magnetic resonance imaging ultrashort echo-time cones for assessing lung density in pediatric patients

被引:10
|
作者
Zeimpekis, Konstantinos G. [1 ,2 ]
Geiger, Julia [3 ,4 ]
Wiesinger, Florian [5 ]
Delso, Gaspar [5 ]
Kellenberger, Christian J. [3 ,4 ]
机构
[1] Univ Hosp Zurich, Dept Nucl Med, Raemistr 100, CH-8091 Zurich, Switzerland
[2] ETH, Dept Informat Technol & Elect Engn, Zurich, Switzerland
[3] Univ Childrens Hosp Zurich, Dept Diagnost Imaging, Zurich, Switzerland
[4] Univ Childrens Hosp Zurich, Childrens Res Ctr, Zurich, Switzerland
[5] GE Healthcare, Waukesha, WI USA
关键词
Adolescents; Children; Cones; Cystic fibrosis; Lung density; Magnetic resonance imaging; Ultra-short echo time; OVERLAPPING PARALLEL LINES; ENHANCED RECONSTRUCTION PROPELLER; COMPUTED-TOMOGRAPHY; MOTION CORRECTION; CT DENSITY; MRI; DISEASE; QUALITY; HEAD;
D O I
10.1007/s00247-020-04791-1
中图分类号
R72 [儿科学];
学科分类号
100202 ;
摘要
Background MRI of lung parenchyma is challenging because of the rapid decay of signal by susceptibility effects of aerated lung on routine fast spin-echo sequences. Objective To assess lung signal intensity in children on ultrashort echo-time sequences in comparison to a fast spin-echo technique. Materials and methods We conducted a retrospective study of lung MRI obtained in 30 patients (median age 5 years, range 2 months to 18 years) including 15 with normal lungs and 15 with cystic fibrosis. On a fast spin-echo sequence with radial readout and an ultrashort echo-time sequence, both lungs were segmented and signal intensities were extracted. We compared lung-to-background signal ratios and histogram analysis between the two patient cohorts using non-parametric tests and correlation analysis. Results On ultrashort echo-time the lung-to-background ratio was age-dependent, ranging from 3.15 to 1.33 with high negative correlation (R-s= -0.86). Signal in posterior dependent portions of the lung was 18% and 11% higher than that of the anterior lung for age groups 0-2 and 2-18 years, respectively. The fast spin-echo sequence showed no variation of signal ratios by age or location, with a median of 0.99 (0.98-1.02). Histograms of ultrashort echo-time slices between controls and children with aggravated cystic fibrosis with mucus plugging and wall thickening exhibited significant discrepancies that differentiated between normal and pathological lungs. Conclusion Signal intensity of lung on ultrashort echo-time is higher than that on fast spin-echo sequences, is age-dependent and shows a gravity-dependent anterior to posterior gradient. This signal variation appears similar to lung density described on CT.
引用
收藏
页码:57 / 65
页数:9
相关论文
共 50 条
  • [21] Fast quantitative three-dimensional ultrashort echo time (UTE) Cones magnetic resonance imaging of major tissues in the knee joint using extended sprial sampling
    Wan, Lidi
    Ma, Yajun
    Yang, Jiawei
    Jerban, Saeed
    Searleman, Adam C.
    Carl, Michael
    Le, Nicole
    Chang, Eric Y.
    Tang, Guangyu
    Du, Jiang
    NMR IN BIOMEDICINE, 2020, 33 (10)
  • [22] Comparison of lung imaging using three-dimensional ultrashort echo time and zero echo time sequences: preliminary study
    Kyungsoo Bae
    Kyung Nyeo Jeon
    Moon Jung Hwang
    Joon Sung Lee
    Ji Young Ha
    Kyeong Hwa Ryu
    Ho Cheol Kim
    European Radiology, 2019, 29 : 2253 - 2262
  • [23] Comparison of lung imaging using three-dimensional ultrashort echo time and zero echo time sequences: preliminary study
    Bae, Kyungsoo
    Jeon, Kyung Nyeo
    Hwang, Moon Jung
    Lee, Joon Sung
    Ha, Ji Young
    Ryu, Kyeong Hwa
    Kim, Ho Cheol
    EUROPEAN RADIOLOGY, 2019, 29 (05) : 2253 - 2262
  • [24] Three-dimensional Ultrashort Echotime Magnetic Resonance Imaging for Combined Morphologic and Ventilation Imaging in Pediatric Patients With Pulmonary Disease
    Veldhoen, Simon
    Heidenreich, Julius F.
    Metz, Corona
    Petritsch, Bernhard
    Benkert, Thomas
    Hebestreit, Helge U.
    Bley, Thorsten A.
    Kostler, Herbert
    Weng, Andreas M.
    JOURNAL OF THORACIC IMAGING, 2021, 36 (01) : 43 - 51
  • [25] Accelerated Stack-of-Spirals Free-Breathing Three-Dimensional Ultrashort Echo Time Lung Magnetic Resonance Imaging: A Feasibility Study in Patients With Breast Cancer
    Cha, Min Jae
    Ahn, Hye Shin
    Choi, Hyewon
    Park, Hyun Jeong
    Benkert, Thomas
    Pfeuffer, Josef
    Paek, Mun Young
    FRONTIERS IN ONCOLOGY, 2021, 11
  • [26] Optimized three-dimensional ultrashort echo time: Magnetic resonance fingerprinting for myelin tissue fraction mapping
    Zhou, Zihan
    Li, Qing
    Liao, Congyu
    Cao, Xiaozhi
    Liang, Hui
    Chen, Quan
    Pu, Run
    Ye, Huihui
    Tong, Qiqi
    He, Hongjian
    Zhong, Jianhui
    HUMAN BRAIN MAPPING, 2023, 44 (06) : 2209 - 2223
  • [27] Craniofacial Imaging of Pediatric Patients by Ultrashort Echo-Time Bone- Selective MRI in Comparison to CT
    Kamona, Nada
    Ng, Jinggang J.
    Kim, Yohan
    Vu, Brian-Tinh D.
    Vossough, Arastoo
    Wagner, Connor S.
    Cordray, Holly
    Lee, Hyunyeol
    Villavisanis, Dillan F.
    Rajapakse, Chamith S.
    Bartlett, Scott P.
    Wehrli, Felix W.
    ACADEMIC RADIOLOGY, 2024, 31 (11) : 4629 - 4642
  • [28] Functional magnetic resonance imaging with an ultrashort echo time
    Kim, Min-Ji
    Jahng, Geon-Ho
    Lee, Soo-Yeol
    Ryu, Chang-Woo
    MEDICAL PHYSICS, 2013, 40 (02)
  • [29] Three-dimensional ultrashort echo time cones T1ρ (3D UTE-cones-T1ρ) imaging
    Ma, Ya-Jun
    Carl, Michael
    Shao, Hongda
    Tadros, Anthony S.
    Chang, Eric Y.
    Du, Jiang
    NMR IN BIOMEDICINE, 2017, 30 (06)
  • [30] CT And Ultrashort Echo-Time Mr Imaging Of Cystic Fibrosis Lung Disease In Infants
    Roach, D. J.
    Stein, J. M.
    Walkup, L. L.
    Fleck, R. J.
    Cremillieux, Y.
    Brody, A. S.
    Clancy, J. P.
    Woods, J. C.
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2015, 191