Three-dimensional magnetic resonance imaging ultrashort echo-time cones for assessing lung density in pediatric patients

被引:10
|
作者
Zeimpekis, Konstantinos G. [1 ,2 ]
Geiger, Julia [3 ,4 ]
Wiesinger, Florian [5 ]
Delso, Gaspar [5 ]
Kellenberger, Christian J. [3 ,4 ]
机构
[1] Univ Hosp Zurich, Dept Nucl Med, Raemistr 100, CH-8091 Zurich, Switzerland
[2] ETH, Dept Informat Technol & Elect Engn, Zurich, Switzerland
[3] Univ Childrens Hosp Zurich, Dept Diagnost Imaging, Zurich, Switzerland
[4] Univ Childrens Hosp Zurich, Childrens Res Ctr, Zurich, Switzerland
[5] GE Healthcare, Waukesha, WI USA
关键词
Adolescents; Children; Cones; Cystic fibrosis; Lung density; Magnetic resonance imaging; Ultra-short echo time; OVERLAPPING PARALLEL LINES; ENHANCED RECONSTRUCTION PROPELLER; COMPUTED-TOMOGRAPHY; MOTION CORRECTION; CT DENSITY; MRI; DISEASE; QUALITY; HEAD;
D O I
10.1007/s00247-020-04791-1
中图分类号
R72 [儿科学];
学科分类号
100202 ;
摘要
Background MRI of lung parenchyma is challenging because of the rapid decay of signal by susceptibility effects of aerated lung on routine fast spin-echo sequences. Objective To assess lung signal intensity in children on ultrashort echo-time sequences in comparison to a fast spin-echo technique. Materials and methods We conducted a retrospective study of lung MRI obtained in 30 patients (median age 5 years, range 2 months to 18 years) including 15 with normal lungs and 15 with cystic fibrosis. On a fast spin-echo sequence with radial readout and an ultrashort echo-time sequence, both lungs were segmented and signal intensities were extracted. We compared lung-to-background signal ratios and histogram analysis between the two patient cohorts using non-parametric tests and correlation analysis. Results On ultrashort echo-time the lung-to-background ratio was age-dependent, ranging from 3.15 to 1.33 with high negative correlation (R-s= -0.86). Signal in posterior dependent portions of the lung was 18% and 11% higher than that of the anterior lung for age groups 0-2 and 2-18 years, respectively. The fast spin-echo sequence showed no variation of signal ratios by age or location, with a median of 0.99 (0.98-1.02). Histograms of ultrashort echo-time slices between controls and children with aggravated cystic fibrosis with mucus plugging and wall thickening exhibited significant discrepancies that differentiated between normal and pathological lungs. Conclusion Signal intensity of lung on ultrashort echo-time is higher than that on fast spin-echo sequences, is age-dependent and shows a gravity-dependent anterior to posterior gradient. This signal variation appears similar to lung density described on CT.
引用
收藏
页码:57 / 65
页数:9
相关论文
共 50 条
  • [31] Fast Magnetic Resonance Spectroscopic Imaging Using Echo-Time Optimization
    Deng, Wenting
    Reeves, Stanley
    Twieg, Donald B.
    2010 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD (NSS/MIC), 2010, : 2116 - 2118
  • [32] Quantification Of Neonatal Lung Parenchymal Density Via Ultra-Short Echo-Time (ute) Magnetic Resonance Imaging (mri)
    Higano, N. S.
    Walkup, L. L.
    Hahn, A.
    Thomen, R.
    Merhar, S.
    Kingma, P. S.
    Tkach, J. A.
    Fain, S.
    Woods, J. C.
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2016, 193
  • [33] Magnetic resonance imaging of the zone of calcified cartilage in the knee joint using 3-dimensional ultrashort echo time cones sequences
    Liu Jin
    Wei Yang
    Ma Ya-Jun
    Zhu Yan-Chun
    Zhou Quan
    Zhao Ying-Hua
    中华医学杂志英文版, 2019, 132 (05) : 562 - 568
  • [34] Magnetic resonance imaging of the zone of calcified cartilage in the knee joint using 3-dimensional ultrashort echo time cones sequences
    Liu, Jin
    Wei, Yang
    Ma, Ya-Jun
    Zhu, Yan-Chun
    Zhou, Quan
    Zhao, Ying-Hua
    CHINESE MEDICAL JOURNAL, 2019, 132 (05) : 562 - 568
  • [35] Ultrashort echo time magnetic resonance imaging of the osteochondral junction
    Lombardi, Alecio F.
    Guma, Monica
    Chung, Christine B.
    Chang, Eric Y.
    Du, Jiang
    Ma, Ya-Jun
    NMR IN BIOMEDICINE, 2023, 36 (02)
  • [36] Short T2 contrast with three-dimensional ultrashort echo time imaging
    Du, Jiang
    Bydder, Mark
    Takahashi, Atsushi M.
    Carl, Michael
    Chung, Christine B.
    Bydder, Graeme M.
    MAGNETIC RESONANCE IMAGING, 2011, 29 (04) : 470 - 482
  • [37] Three-dimensional ultrashort echo time imaging with tricomponent analysis for human cortical bone
    Lu, Xing
    Jerban, Saeed
    Wan, Lidi
    Ma, Yajun
    Jang, Hyungseok
    Le, Nicole
    Yang, Wenhui
    Chang, Eric Y.
    Du, Jiang
    MAGNETIC RESONANCE IN MEDICINE, 2019, 82 (01) : 348 - 355
  • [38] Three-dimensional ultrashort echo time magnetic resonance imaging in assessment of idiopathic pulmonary fibrosis, in comparison with high-resolution computed tomography
    Yang, Xiaoyan
    Liu, Min
    Duan, Jianghui
    Sun, Haishuang
    An, Jing
    Benkert, Thomas
    Dai, Huaping
    Wang, Chen
    QUANTITATIVE IMAGING IN MEDICINE AND SURGERY, 2022, 12 (08) : 4176 - +
  • [39] Ability of three-dimensional 3-Tesla ultrashort echo time magnetic resonance imaging to display the morphological characteristics of pulmonary nodules: a sensitivity analysis
    Wang, Funan
    Lin, Xi
    Lin, Chong
    Huang, Guoqiang
    Li, Min
    Zhu, Liuhong
    QUANTITATIVE IMAGING IN MEDICINE AND SURGERY, 2023, 13 (03) : 1792 - 1801
  • [40] Depiction of Achilles Tendon Microstructure In Vivo Using High-Resolution 3-Dimensional Ultrashort Echo-Time Magnetic Resonance Imaging at 7 T
    Han, Misung
    Larson, Peder E. Z.
    Liu, Jing
    Krug, Roland
    INVESTIGATIVE RADIOLOGY, 2014, 49 (05) : 339 - 345