Three-dimensional magnetic resonance imaging ultrashort echo-time cones for assessing lung density in pediatric patients

被引:10
|
作者
Zeimpekis, Konstantinos G. [1 ,2 ]
Geiger, Julia [3 ,4 ]
Wiesinger, Florian [5 ]
Delso, Gaspar [5 ]
Kellenberger, Christian J. [3 ,4 ]
机构
[1] Univ Hosp Zurich, Dept Nucl Med, Raemistr 100, CH-8091 Zurich, Switzerland
[2] ETH, Dept Informat Technol & Elect Engn, Zurich, Switzerland
[3] Univ Childrens Hosp Zurich, Dept Diagnost Imaging, Zurich, Switzerland
[4] Univ Childrens Hosp Zurich, Childrens Res Ctr, Zurich, Switzerland
[5] GE Healthcare, Waukesha, WI USA
关键词
Adolescents; Children; Cones; Cystic fibrosis; Lung density; Magnetic resonance imaging; Ultra-short echo time; OVERLAPPING PARALLEL LINES; ENHANCED RECONSTRUCTION PROPELLER; COMPUTED-TOMOGRAPHY; MOTION CORRECTION; CT DENSITY; MRI; DISEASE; QUALITY; HEAD;
D O I
10.1007/s00247-020-04791-1
中图分类号
R72 [儿科学];
学科分类号
100202 ;
摘要
Background MRI of lung parenchyma is challenging because of the rapid decay of signal by susceptibility effects of aerated lung on routine fast spin-echo sequences. Objective To assess lung signal intensity in children on ultrashort echo-time sequences in comparison to a fast spin-echo technique. Materials and methods We conducted a retrospective study of lung MRI obtained in 30 patients (median age 5 years, range 2 months to 18 years) including 15 with normal lungs and 15 with cystic fibrosis. On a fast spin-echo sequence with radial readout and an ultrashort echo-time sequence, both lungs were segmented and signal intensities were extracted. We compared lung-to-background signal ratios and histogram analysis between the two patient cohorts using non-parametric tests and correlation analysis. Results On ultrashort echo-time the lung-to-background ratio was age-dependent, ranging from 3.15 to 1.33 with high negative correlation (R-s= -0.86). Signal in posterior dependent portions of the lung was 18% and 11% higher than that of the anterior lung for age groups 0-2 and 2-18 years, respectively. The fast spin-echo sequence showed no variation of signal ratios by age or location, with a median of 0.99 (0.98-1.02). Histograms of ultrashort echo-time slices between controls and children with aggravated cystic fibrosis with mucus plugging and wall thickening exhibited significant discrepancies that differentiated between normal and pathological lungs. Conclusion Signal intensity of lung on ultrashort echo-time is higher than that on fast spin-echo sequences, is age-dependent and shows a gravity-dependent anterior to posterior gradient. This signal variation appears similar to lung density described on CT.
引用
收藏
页码:57 / 65
页数:9
相关论文
共 50 条
  • [41] Three-dimensional adiabatic inversion recovery prepared ultrashort echo time cones (3D IR-UTE-Cones) imaging of cortical bone in the hip
    Nazaran, Amin
    Carl, Michael
    Ma, Yajun
    Jerban, Saeed
    Zhu, Yanchun
    Lu, Xing
    Du, Jiang
    Chang, Eric Y.
    MAGNETIC RESONANCE IMAGING, 2017, 44 : 60 - 64
  • [42] Review of the ultrashort echo time magnetic resonance imaging of cortical bone
    Bao Shang-Lian
    Du Jiang
    Gao Song
    ACTA PHYSICA SINICA, 2013, 62 (08)
  • [43] Three-Dimensional Phase Resolved Functional Lung Magnetic Resonance Imaging
    Klimes, Filip
    Voskrebenzev, Andreas
    Wacker, Frank
    Vogel-Claussen, Jens
    JOVE-JOURNAL OF VISUALIZED EXPERIMENTS, 2024, (208):
  • [44] Tissue Electrical Property Mapping From Zero Echo-Time Magnetic Resonance Imaging
    Lee, Seung-Kyun
    Bulumulla, Selaka
    Wiesinger, Florian
    Sacolick, Laura
    Sun, Wei
    Hancu, Ileana
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2015, 34 (02) : 541 - 550
  • [45] Ultra-short echo-time magnetic resonance imaging lung segmentation with under-Annotations and domain shift
    Guo, Fumin
    Capaldi, Dante Pi
    McCormack, David G.
    Fenster, Aaron
    Parraga, Grace
    MEDICAL IMAGE ANALYSIS, 2021, 72
  • [46] Pulmonary Embolism Detection with Three-dimensional Ultrashort Echo Time MR Imaging: Experimental Study in Canines
    Bannas, Peter
    Bell, Laura C.
    Johnson, Kevin M.
    Schiebler, Mark L.
    Francois, Christopher J.
    Motosugi, Utaroh
    Consigny, Daniel
    Reeder, Scott B.
    Nagle, Scott K.
    RADIOLOGY, 2016, 278 (02) : 413 - 421
  • [47] Three-Dimensional Assessment of Lung Tissue Density Using a Clinical Ultrashort Echo Time at 3 Tesla: A Feasibility Study in Healthy Subjects
    Lederlin, Mathieu
    Cremillieux, Yannick
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2014, 40 (04) : 839 - 847
  • [48] Three-dimensional magnetic resonance imaging for groundwater
    Legchenko, A.
    Descloitres, M.
    Vincent, C.
    Guyard, H.
    Garambois, S.
    Chalikakis, K.
    Ezersky, M.
    NEW JOURNAL OF PHYSICS, 2011, 13
  • [49] An Update in Qualitative Imaging of Bone Using Ultrashort Echo Time Magnetic Resonance
    Jerban, Saeed
    Chang, Douglas G.
    Ma, Yajun
    Jang, Hyungseok
    Chang, Eric Y.
    Du, Jiang
    FRONTIERS IN ENDOCRINOLOGY, 2020, 11
  • [50] Quantitative Ultrashort Echo Time (UTE) Magnetic Resonance Imaging of Bone: An Update
    Ma, Ya-Jun
    Jerban, Saeed
    Jang, Hyungseok
    Chang, Douglas
    Chang, Eric Y.
    Du, Jiang
    FRONTIERS IN ENDOCRINOLOGY, 2020, 11