Optimized three-dimensional ultrashort echo time: Magnetic resonance fingerprinting for myelin tissue fraction mapping

被引:7
|
作者
Zhou, Zihan [1 ,2 ]
Li, Qing [1 ,3 ]
Liao, Congyu [4 ,5 ]
Cao, Xiaozhi [4 ,5 ]
Liang, Hui [6 ]
Chen, Quan [4 ,5 ]
Pu, Run [7 ]
Ye, Huihui [8 ]
Tong, Qiqi [9 ]
He, Hongjian [1 ,2 ,10 ]
Zhong, Jianhui [1 ,11 ]
机构
[1] Zhejiang Univ, Coll Biomed Engn & Instrument Sci, Ctr Brain Imaging Sci & Technol, Hangzhou, Zhejiang, Peoples R China
[2] Zhejiang Univ, Key Lab Biomed Engn, Minist Educ, Hangzhou, Zhejiang, Peoples R China
[3] MR Collaborat Siemens Healthineers Ltd, Shanghai, Peoples R China
[4] Stanford Univ, Dept Radiol, Stanford, CA USA
[5] Stanford Univ, Dept Elect Engn, Stanford, CA USA
[6] Zhejiang Univ, Affiliated Hosp 1, Sch Med, Dept Neurol, Hangzhou, Zhejiang, Peoples R China
[7] Neusoft Med Syst, Shanghai, Peoples R China
[8] Zhejiang Univ, Coll Opt Sci & Engn, State Key Lab Modern Opt Instrumentat, Hangzhou, Zhejiang, Peoples R China
[9] Res Ctr Healthcare Data Sci, Zhejiang Lab, Hangzhou, Zhejiang, Peoples R China
[10] Zhejiang Univ, Sch Phys, Hangzhou, Zhejiang, Peoples R China
[11] Univ Rochester, Dept Imaging Sci, Rochester, NY USA
基金
中国国家自然科学基金;
关键词
3D; Cramer-Rao lower bound; magnetic resonance fingerprinting; myelin tissue fraction mapping; myelin-proton; ultrashort echo time; MULTIPLE-SCLEROSIS; SLIDING-WINDOW; HUMAN BRAIN; WATER; MR; VISUALIZATION; ACQUISITION; RECONSTRUCTION; SPIRALS; STACK;
D O I
10.1002/hbm.26203
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
Quantitative assessment of brain myelination has gained attention for both research and diagnosis of neurological diseases. However, conventional pulse sequences cannot directly acquire the myelin-proton signals due to its extremely short T2 and T2* values. To obtain the myelin-proton signals, dedicated short T2 acquisition techniques, such as ultrashort echo time (UTE) imaging, have been introduced. However, it remains challenging to isolate the myelin-proton signals from tissues with longer T2. In this article, we extended our previous two-dimensional ultrashort echo time magnetic resonance fingerprinting (UTE-MRF) with dual-echo acquisition to three dimensional (3D). Given a relatively low proton density (PD) of myelin-proton, we utilized Cramer-Rao Lower Bound to encode myelin-proton with the maximal SNR efficiency for optimizing the MR fingerprinting design, in order to improve the sensitivity of the sequence to myelin-proton. In addition, with a second echo of approximately 3 ms, myelin-water component can be also captured. A myelin-tissue (myelin-proton and myelin-water) fraction mapping can be thus calculated. The optimized 3D UTE-MRF with dual-echo acquisition is tested in simulations, physical phantom and in vivo studies of both healthy subjects and multiple sclerosis patients. The results suggest that the rapidly decayed myelin-proton and myelin-water signal can be depicted with UTE signals of our method at clinically relevant resolution (1.8 mm isotropic) in 15 min. With its good sensitivity to myelin loss in multiple sclerosis patients demonstrated, our method for the whole brain myelin-tissue fraction mapping in clinical friendly scan time has the potential for routine clinical imaging.
引用
收藏
页码:2209 / 2223
页数:15
相关论文
共 50 条
  • [1] Three-dimensional ultrashort echo time magnetic resonance imaging in pediatric patients with pneumonia: a comparative study
    Sun, Yan
    Chen, Yujie
    Li, Xuesheng
    Liao, Yi
    Chen, Xijian
    Song, Yu
    Liang, Xinyue
    Dai, Yongming
    Chen, Dapeng
    Ning, Gang
    BMC MEDICAL IMAGING, 2023, 23 (01)
  • [2] Three-dimensional ultrashort echo time magnetic resonance imaging in pediatric patients with pneumonia: a comparative study
    Yan Sun
    Yujie Chen
    Xuesheng Li
    Yi Liao
    Xijian Chen
    Yu Song
    Xinyue Liang
    Yongming Dai
    Dapeng Chen
    Gang Ning
    BMC Medical Imaging, 23
  • [3] Three-dimensional ultrashort echo magnetic resonance imaging of orthodontic appliances in the natural dentition
    Cox, Ryan J.
    Kau, Chung How
    Rasche, Volker
    AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2012, 142 (04) : 552 - 561
  • [4] Feasibility of three-dimensional ultrashort echo time magnetic resonance imaging at 1.5 T for the diagnosis of skull fractures
    Hao Wu
    Yu-min Zhong
    Quan-min Nie
    Wei-bo Chen
    Lie-mei Guo
    Xi Yang
    Hong Zhang
    Yi Lin
    Jian-rong Xu
    Yong-ming Dai
    Ming Zhu
    European Radiology, 2016, 26 : 138 - 146
  • [5] Feasibility of three-dimensional ultrashort echo time magnetic resonance imaging at 1.5 T for the diagnosis of skull fractures
    Wu, Hao
    Zhong, Yu-min
    Nie, Quan-min
    Chen, Wei-bo
    Guo, Lie-mei
    Yang, Xi
    Zhang, Hong
    Lin, Yi
    Xu, Jian-rong
    Dai, Yong-ming
    Zhu, Ming
    EUROPEAN RADIOLOGY, 2016, 26 (01) : 138 - 146
  • [6] Three-dimensional magnetic resonance imaging ultrashort echo-time cones for assessing lung density in pediatric patients
    Konstantinos G. Zeimpekis
    Julia Geiger
    Florian Wiesinger
    Gaspar Delso
    Christian J. Kellenberger
    Pediatric Radiology, 2021, 51 : 57 - 65
  • [7] Assessment of the sacroiliac joint in patients with axial spondyloarthritis via three-dimensional ultrashort echo time magnetic resonance imaging
    Ren, Cui
    Zhu, Qiao
    Li, Qing
    Sommer, Stefan
    Zhang, Xianchang
    Yuan, Huishu
    QUANTITATIVE IMAGING IN MEDICINE AND SURGERY, 2024, 14 (06) : 4141 - 4154
  • [8] Three-dimensional magnetic resonance imaging ultrashort echo-time cones for assessing lung density in pediatric patients
    Zeimpekis, Konstantinos G.
    Geiger, Julia
    Wiesinger, Florian
    Delso, Gaspar
    Kellenberger, Christian J.
    PEDIATRIC RADIOLOGY, 2021, 51 (01) : 57 - 65
  • [9] Ultrashort echo time (UTE) magnetic resonance imaging of myelin: technical developments and challenges
    Ma, Ya-Jun
    Jang, Hyungseok
    Chang, Eric Y.
    Hiniker, Annie
    Head, Brian P.
    Lee, Roland R.
    Corey-Bloom, Jody
    Bydder, Graeme M.
    Du, Jiang
    QUANTITATIVE IMAGING IN MEDICINE AND SURGERY, 2020, 10 (06) : 1186 - 1203
  • [10] Assessment of mechanical properties of articular cartilage with quantitative three-dimensional ultrashort echo time (UTE) cones magnetic resonance imaging
    Namiranian, Behnam
    Jerban, Saeed
    Ma, Yajun
    Dorthe, Erik W.
    Masoud-Afsahi, Amir
    Wong, Jonathan
    Wei, Zhao
    Chen, Yanjun
    D'Lima, Darryl
    Chang, Eric Y.
    Du, Jiang
    JOURNAL OF BIOMECHANICS, 2020, 113