Three-dimensional magnetic resonance imaging ultrashort echo-time cones for assessing lung density in pediatric patients

被引:10
|
作者
Zeimpekis, Konstantinos G. [1 ,2 ]
Geiger, Julia [3 ,4 ]
Wiesinger, Florian [5 ]
Delso, Gaspar [5 ]
Kellenberger, Christian J. [3 ,4 ]
机构
[1] Univ Hosp Zurich, Dept Nucl Med, Raemistr 100, CH-8091 Zurich, Switzerland
[2] ETH, Dept Informat Technol & Elect Engn, Zurich, Switzerland
[3] Univ Childrens Hosp Zurich, Dept Diagnost Imaging, Zurich, Switzerland
[4] Univ Childrens Hosp Zurich, Childrens Res Ctr, Zurich, Switzerland
[5] GE Healthcare, Waukesha, WI USA
关键词
Adolescents; Children; Cones; Cystic fibrosis; Lung density; Magnetic resonance imaging; Ultra-short echo time; OVERLAPPING PARALLEL LINES; ENHANCED RECONSTRUCTION PROPELLER; COMPUTED-TOMOGRAPHY; MOTION CORRECTION; CT DENSITY; MRI; DISEASE; QUALITY; HEAD;
D O I
10.1007/s00247-020-04791-1
中图分类号
R72 [儿科学];
学科分类号
100202 ;
摘要
Background MRI of lung parenchyma is challenging because of the rapid decay of signal by susceptibility effects of aerated lung on routine fast spin-echo sequences. Objective To assess lung signal intensity in children on ultrashort echo-time sequences in comparison to a fast spin-echo technique. Materials and methods We conducted a retrospective study of lung MRI obtained in 30 patients (median age 5 years, range 2 months to 18 years) including 15 with normal lungs and 15 with cystic fibrosis. On a fast spin-echo sequence with radial readout and an ultrashort echo-time sequence, both lungs were segmented and signal intensities were extracted. We compared lung-to-background signal ratios and histogram analysis between the two patient cohorts using non-parametric tests and correlation analysis. Results On ultrashort echo-time the lung-to-background ratio was age-dependent, ranging from 3.15 to 1.33 with high negative correlation (R-s= -0.86). Signal in posterior dependent portions of the lung was 18% and 11% higher than that of the anterior lung for age groups 0-2 and 2-18 years, respectively. The fast spin-echo sequence showed no variation of signal ratios by age or location, with a median of 0.99 (0.98-1.02). Histograms of ultrashort echo-time slices between controls and children with aggravated cystic fibrosis with mucus plugging and wall thickening exhibited significant discrepancies that differentiated between normal and pathological lungs. Conclusion Signal intensity of lung on ultrashort echo-time is higher than that on fast spin-echo sequences, is age-dependent and shows a gravity-dependent anterior to posterior gradient. This signal variation appears similar to lung density described on CT.
引用
收藏
页码:57 / 65
页数:9
相关论文
共 50 条
  • [1] Three-dimensional magnetic resonance imaging ultrashort echo-time cones for assessing lung density in pediatric patients
    Konstantinos G. Zeimpekis
    Julia Geiger
    Florian Wiesinger
    Gaspar Delso
    Christian J. Kellenberger
    Pediatric Radiology, 2021, 51 : 57 - 65
  • [2] Assessment of lung density in pediatric patients using three-dimensional ultrashort echo-time and four-dimensional zero echo-time sequences
    Konstantinos G. Zeimpekis
    Christian J. Kellenberger
    Julia Geiger
    Japanese Journal of Radiology, 2022, 40 : 722 - 729
  • [3] Assessment of lung density in pediatric patients using three-dimensional ultrashort echo-time and four-dimensional zero echo-time sequences
    Zeimpekis, Konstantinos G.
    Kellenberger, Christian J.
    Geiger, Julia
    JAPANESE JOURNAL OF RADIOLOGY, 2022, 40 (07) : 722 - 729
  • [4] Three-dimensional ultrashort echo time magnetic resonance imaging in pediatric patients with pneumonia: a comparative study
    Sun, Yan
    Chen, Yujie
    Li, Xuesheng
    Liao, Yi
    Chen, Xijian
    Song, Yu
    Liang, Xinyue
    Dai, Yongming
    Chen, Dapeng
    Ning, Gang
    BMC MEDICAL IMAGING, 2023, 23 (01)
  • [5] Three-dimensional ultrashort echo time magnetic resonance imaging in pediatric patients with pneumonia: a comparative study
    Yan Sun
    Yujie Chen
    Xuesheng Li
    Yi Liao
    Xijian Chen
    Yu Song
    Xinyue Liang
    Yongming Dai
    Dapeng Chen
    Gang Ning
    BMC Medical Imaging, 23
  • [6] Three-dimensional ultrashort echo-time imaging using a FLORET trajectory
    Robison, Ryan K.
    Anderson, Ashley G., III
    Pipe, James G.
    MAGNETIC RESONANCE IN MEDICINE, 2017, 78 (03) : 1038 - 1049
  • [7] Three-dimensional ultrashort echo time cones (3D UTE-Cones) magnetic resonance imaging of entheses and tendons
    Chen, Bimin
    Zhao, Yinghua
    Cheng, Xin
    Ma, Yajun
    Chang, Eric Y.
    Kavanaugh, Arthur
    Liu, Sirun
    Du, Jiang
    MAGNETIC RESONANCE IMAGING, 2018, 49 : 4 - 9
  • [8] Assessment of mechanical properties of articular cartilage with quantitative three-dimensional ultrashort echo time (UTE) cones magnetic resonance imaging
    Namiranian, Behnam
    Jerban, Saeed
    Ma, Yajun
    Dorthe, Erik W.
    Masoud-Afsahi, Amir
    Wong, Jonathan
    Wei, Zhao
    Chen, Yanjun
    D'Lima, Darryl
    Chang, Eric Y.
    Du, Jiang
    JOURNAL OF BIOMECHANICS, 2020, 113
  • [9] Three-dimensional radial ultrashort echo-time imaging with T2 adapted sampling
    Rahmer, J
    Börnert, P
    Groen, J
    Bos, C
    MAGNETIC RESONANCE IN MEDICINE, 2006, 55 (05) : 1075 - 1082
  • [10] Ultrashort Echo-Time MR Imaging of the Pediatric Head and Neck
    Kobayashi, Naoharu
    Bambach, Sven
    Ho, Mai-Lan
    MAGNETIC RESONANCE IMAGING CLINICS OF NORTH AMERICA, 2021, 29 (04) : 583 - 593