GADH screen-printed biosensor for gluconic acid determination in wine samples

被引:11
|
作者
del Torno-de Roman, Lorena [1 ]
Asuncion Alonso-Lomillo, M. [1 ]
Dominguez-Renedo, Olga [1 ]
Jaureguibeitia, Arrate [2 ]
Julia Arcos-Martinez, M. [1 ]
机构
[1] Univ Burgos, Fac Sci, Dept Analyt Chem, Burgos 09001, Spain
[2] Biolan Microbiosensores SL, Parque Tecnol Vizcaya, Zamudio 48170, Spain
关键词
Screen-printed carbon electrodes; Chronoamperometric biosensor; Gluconate dehydrogenase; Tetrathiafulvalene; Gluconic acid; CAPILLARY-ZONE-ELECTROPHORESIS; ORGANIC-ACIDS; HPLC DETERMINATION; CARBOXYLIC-ACIDS; SUGAR ACIDS; QUANTIFICATION; CHROMATOGRAPHY; SPECTROSCOPY; ELECTRODES; PARAMETERS;
D O I
10.1016/j.snb.2013.10.098
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Gluconate dehydrogenase (GADH) biosensors have been developed for the satisfactory determination of gluconic acid in wine samples, without any pretreatment. The biosensors have been fabricated by cross-linking immobilization of GADH onto screen-printed carbon electrodes, containing the mediator tetrathiafulvalene (TTF). Chronoamperograms have been registered at +100 mV vs. screen-printed Ag/AgCl electrode by successive additions of a gluconic acid solution in the concentration range from 9.0 to 131.4 mu M. This method shows a reproducibility of 8.1% (n = 3) related to the slopes of these calibration curves and a repeatability of 3.2% (n = 5). The procedure has shown an average capability of detection of 9.0 mu M for a probability of false positive and negative of 0.05. Wine samples have been analyzed with these biosensors, obtaining satisfactory results. (C) 2013 Elsevier B.V. All rights reserved.
引用
收藏
页码:56 / 59
页数:4
相关论文
共 50 条
  • [21] Disposable screen-printed biosensor for transcutaneous oxygen measurement
    Lam, YZ
    Atkinson, J
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2002, 13 (12) : 2074 - 2081
  • [22] Study on electrochemical biosensor based on screen-printed electrode
    Zou, Quan
    Cheng, Gong
    Zhang, Yu
    MODERN PHYSICS LETTERS B, 2018, 32 (34-36):
  • [23] Enantio selective screen-printed amperometric biosensor for the determination of D-amino acids
    Wcislo, Marzena
    Compagnone, Dario
    Trojanowicz, Marek
    BIOELECTROCHEMISTRY, 2007, 71 (01) : 91 - 98
  • [24] Development of a screen-printed amperometric biosensor for the determination of L-lactate dehydrogenase level
    Hong, MY
    Chang, JY
    Yoon, HC
    Kim, HS
    BIOSENSORS & BIOELECTRONICS, 2002, 17 (1-2): : 13 - 18
  • [25] A screen-printed biosensor using pyruvate oxidase for rapid determination of phosphate in synthetic wastewater
    Roger C. H. Kwan
    H. F. Leung
    Phoebe Y. T. Hon
    J. P. Barford
    R. Renneberg
    Applied Microbiology and Biotechnology, 2005, 66 : 377 - 383
  • [26] Development of Screen-Printed Electrode Biosensor for Rapid Determination of Triglyceride Content in Coconut Milk
    Manoj, D.
    Auddy, Ishita
    Nimbkar, Shubham
    Chittibabu, S.
    Shanmugasundaram, S.
    INTERNATIONAL JOURNAL OF FOOD SCIENCE, 2020, 2020
  • [27] Screen-printed enzymatic biosensor modified with carbon nanotube for the methimazole determination in pharmaceuticals formulations
    Martinez, Noelia A.
    Messina, German A.
    Bertolino, Franco A.
    Salinas, Eloy
    Raba, Julio
    SENSORS AND ACTUATORS B-CHEMICAL, 2008, 133 (01): : 256 - 262
  • [28] A screen-printed biosensor using pyruvate oxidase for rapid determination of phosphate in synthetic wastewater
    Kwan, RCH
    Leung, HF
    Hon, PYT
    Barford, JP
    Renneberg, R
    APPLIED MICROBIOLOGY AND BIOTECHNOLOGY, 2005, 66 (04) : 377 - 383
  • [29] A new screen-printed electrode for selective determination of bismuth in different authentic samples
    Aglan, Refaat F.
    Hamed, Mostafa M.
    Saleh, Hosam M.
    JOURNAL OF THE IRANIAN CHEMICAL SOCIETY, 2023, 20 (06) : 1481 - 1490
  • [30] Screen-printed sensor for determination of sildenafil citrate in pharmaceutical preparations and biological samples
    Sasal, Agnieszka
    Tyszczuk-Rotko, Katarzyna
    MICROCHEMICAL JOURNAL, 2019, 149