摘要
Gluconate dehydrogenase (GADH) biosensors have been developed for the satisfactory determination of gluconic acid in wine samples, without any pretreatment. The biosensors have been fabricated by cross-linking immobilization of GADH onto screen-printed carbon electrodes, containing the mediator tetrathiafulvalene (TTF). Chronoamperograms have been registered at +100 mV vs. screen-printed Ag/AgCl electrode by successive additions of a gluconic acid solution in the concentration range from 9.0 to 131.4 mu M. This method shows a reproducibility of 8.1% (n = 3) related to the slopes of these calibration curves and a repeatability of 3.2% (n = 5). The procedure has shown an average capability of detection of 9.0 mu M for a probability of false positive and negative of 0.05. Wine samples have been analyzed with these biosensors, obtaining satisfactory results. (C) 2013 Elsevier B.V. All rights reserved.
引用
收藏
页码:56 / 59
页数:4
相关论文
共 50 条
  • [31] Sarcosine oxidase composite screen-printed electrode for sarcosine determination in biological samples
    Rebelo, Tania S. C. R.
    Pereira, Carlos M.
    Sales, M. Goreti F.
    Noronha, Joao P.
    Costa-Rodrigues, J.
    Silva, Fernando
    Fernandes, M. H.
    ANALYTICA CHIMICA ACTA, 2014, 850 : 26 - 32
  • [32] Modified Screen-Printed Electrode for Potentiometric Determination of Copper(II) in Water Samples
    Ali, Tamer Awad
    Mohamed, Gehad G.
    El-Dessouky, Maher M. I.
    Abou El-Ella, Salwa M.
    Mohamed, Rabab T. F.
    JOURNAL OF SOLUTION CHEMISTRY, 2013, 42 (06) : 1336 - 1354
  • [33] A new screen-printed electrode for selective determination of bismuth in different authentic samples
    Refaat F. Aglan
    Mostafa M. Hamed
    Hosam M. Saleh
    Journal of the Iranian Chemical Society, 2023, 20 : 1481 - 1490
  • [34] Determination of bisphenol A in real samples using modified graphite screen-printed electrode
    Safavi Gerdin, Hesam
    Sarhadi, Hamid
    Tajik, Somayeh
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL ANALYTICAL CHEMISTRY, 2022, 102 (17) : 4986 - 4995
  • [35] Modified Screen-Printed Electrode for Potentiometric Determination of Copper(II) in Water Samples
    Tamer Awad Ali
    Gehad G. Mohamed
    Maher M. I. El-Dessouky
    Salwa M. Abou El-Ella
    Rabab T. F. Mohamed
    Journal of Solution Chemistry, 2013, 42 : 1336 - 1354
  • [36] Development of a sandwich format, amperometric screen-printed uric acid biosensor for urine analysis
    Kanyong, P.
    Pemberton, R. M.
    Jackson, S. K.
    Hart, J. P.
    ANALYTICAL BIOCHEMISTRY, 2012, 428 (01) : 39 - 43
  • [37] Flow-Through Electrochemical Biosensor with a Replaceable Enzyme Reactor and Screen-Printed Electrode for the Determination of Uric Acid and Tyrosine
    Stoikov, Dmitrii
    Ivanov, Alexey
    Shurpik, Dmitriy
    Stoikov, Ivan
    Evtugyn, Gennady
    ANALYTICAL LETTERS, 2022, 55 (08) : 1281 - 1295
  • [38] Gluconic acid determination in wine by electrochemical biosensing
    del Torno-de Roman, L.
    Alonso-Lomillo, M. A.
    Dominguez-Renedo, O.
    Arcos-Martinez, M. J.
    SENSORS AND ACTUATORS B-CHEMICAL, 2013, 176 : 858 - 862
  • [39] FABRICATION AND CHARACTERIZATION OF A SCREEN-PRINTED, DISPOSABLE, AMPEROMETRIC CHOLESTEROL BIOSENSOR
    GILMARTIN, MAT
    HART, JP
    ANALYST, 1994, 119 (11) : 2331 - 2336
  • [40] Development of an amperometric screen-printed galactose biosensor for serum analysis
    Kanyong, Prosper
    Pemberton, Roy M.
    Jackson, Simon K.
    Hart, John P.
    ANALYTICAL BIOCHEMISTRY, 2013, 435 (02) : 114 - 119