Development of the Computational Human Thoracic Phantom and Estimation of the Organ Absorbed Dose in the Chest Radiography Using Monte Carlo Simulation

被引:0
|
作者
Sato, N. [1 ]
Fujibuchi, T. [1 ]
Yabituchi, H. [1 ]
机构
[1] Kyushu Univ, Fukuoka, Fukuoka, Japan
关键词
D O I
暂无
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
SU-I-GPD-I
引用
收藏
页数:1
相关论文
共 50 条
  • [1] Organ Dose Estimation for Adult Chest CT Examination Using GATE Monte Carlo Simulation
    Tahiri, M.
    Mkimel, M.
    Benameur, Y.
    El Baydaoui, R.
    Mesradi, M. R.
    El Rhazouani, O.
    [J]. PHYSICS OF PARTICLES AND NUCLEI LETTERS, 2021, 18 (04) : 502 - 509
  • [2] Organ Dose Estimation for Adult Chest CT Examination Using GATE Monte Carlo Simulation
    M. Tahiri
    M. Mkimel
    Y. Benameur
    R. El Baydaoui
    M. R. Mesradi
    O. El Rhazouani
    [J]. Physics of Particles and Nuclei Letters, 2021, 18 : 502 - 509
  • [3] Measurement of organ dose in chest CT examination using Monte Carlo simulation
    Harki, E. M. T.
    Al-Kinani, A. T.
    [J]. IRANIAN JOURNAL OF RADIATION RESEARCH, 2007, 4 (04): : 205 - 209
  • [4] Using Monte Carlo Method for estimation of Absorbed Dose in Mammography
    Rezaei, F. Salmani
    Feghhi, S. A.
    Aghamiri, S. M.
    Rezaei, A. Salmani
    Ebrahimi, A.
    [J]. PROCEEDINGS OF THE FOURTH INTERNATIONAL CONFERENCE OF MODELLING AND SIMULATION (ICMS2011), VOL 1, 2011, : 12 - 16
  • [5] Dose-image quality study in digital chest radiography using Monte Carlo simulation
    Correa, S. C. A.
    Souza, E. M.
    Silva, A. X.
    Lopes, R. T.
    Yoriyaz, H.
    [J]. APPLIED RADIATION AND ISOTOPES, 2008, 66 (09) : 1213 - 1217
  • [6] Monte Carlo simulation on heterogeneous phantom and physical dose calculation on heterogeneous organ
    Chemingui, F. Z.
    Benrachi, F.
    Bali, M. S.
    [J]. JOURNAL OF NEW TECHNOLOGY AND MATERIALS, 2019, 9 (02) : 51 - 56
  • [7] Verification of phantom accuracy using a Monte Carlo simulation: bone scintigraphy chest phantom
    Toshimune Ito
    Hirotatsu Tsuchikame
    Hajime Ichikawa
    Masahisa Onoguchi
    Koichi Okuda
    Takayuki Shibutani
    Noriyo Yokotsuka
    Hiroshi Tomizawa
    [J]. Radiological Physics and Technology, 2021, 14 : 336 - 344
  • [8] Verification of phantom accuracy using a Monte Carlo simulation: bone scintigraphy chest phantom
    Ito, Toshimune
    Tsuchikame, Hirotatsu
    Ichikawa, Hajime
    Onoguchi, Masahisa
    Okuda, Koichi
    Shibutani, Takayuki
    Yokotsuka, Noriyo
    Tomizawa, Hiroshi
    [J]. RADIOLOGICAL PHYSICS AND TECHNOLOGY, 2021, 14 (03) : 336 - 344
  • [9] Estimation of organ absorbed dose in pediatric chest X-ray examination: A phantom study
    Jamal, Nurul H. M.
    Sayed, Inayatullah S.
    Syed, Waliullah S.
    [J]. RADIATION PHYSICS AND CHEMISTRY, 2020, 166
  • [10] Development of Monte Carlo Based Voxel Head Phantom for Dose Calculation in Periapical Radiography
    Oh, Y.
    Kang, C.
    An, S.
    Kim, J.
    Ji, Y.
    Lee, R.