Dose-image quality study in digital chest radiography using Monte Carlo simulation

被引:9
|
作者
Correa, S. C. A. [2 ]
Souza, E. M. [2 ]
Silva, A. X. [1 ]
Lopes, R. T. [2 ]
Yoriyaz, H. [3 ]
机构
[1] Univ Fed Rio de Janeiro, PEN COPPF DNC Poli CT, Ilha Fundao, BR-21945970 Rio De Janeiro, Brazil
[2] Univ Fed Rio de Janeiro, Programa Engn Nucl, COPPE, Ilha Fundao, BR-21945970 Rio De Janeiro, Brazil
[3] IPEN CNEN SP, Ilha Fundao, BR-05422270 Sao Paulo, Brazil
关键词
chest radiography; dose-image; Monte Carlo simulation;
D O I
10.1016/j.apradiso.2008.01.009
中图分类号
O61 [无机化学];
学科分类号
070301 ; 081704 ;
摘要
One of the main preoccupations of diagnostic radiology is to guarantee a good image-sparing dose to the patient. In the present study, Monte Carlo Simulations, with MCNPX code, coupled with an adult voxel female model (FAX) were performed to investigate how image quality and dose in digital chest radiography vary with tube voltage (80-150 kV) using air-gap technique and a computed radiography system. Calculated quantities were normalized to a fixed value of entrance skin exposure (ESE) of 0.0136 R. The results of the present analysis show that the image quality for chest radiography with imaging plate is improved and the dose reduced at lower tube voltage. (C) 2008 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1213 / 1217
页数:5
相关论文
共 50 条
  • [1] Dose-image quality optimisation in digital chest radiography
    Doyle, P
    Martin, CJ
    Gentle, D
    [J]. RADIATION PROTECTION DOSIMETRY, 2005, 114 (1-3) : 269 - 272
  • [2] A phantom for dose-image quality optimization in chest radiography
    Vassileva, J
    [J]. BRITISH JOURNAL OF RADIOLOGY, 2002, 75 (898): : 837 - 842
  • [3] Monte Carlo Simulation of Photon Energy and Dose-Image Quality in X-ray Imaging
    He, Wenjun
    Mah, Eugene
    Huda, Walter
    Yao, Hai
    [J]. MEDICAL IMAGING 2012: PHYSICS OF MEDICAL IMAGING, 2012, 8313
  • [4] A MONTE CARLO SIMULATION FRAMEWORK FOR JOINT OPTIMISATION OF IMAGE QUALITY AND PATIENT DOSE IN DIGITAL PAEDIATRIC RADIOGRAPHY
    Menser, Bernd
    Manke, Dirk
    Mentrup, Detlef
    Neitzel, Ulrich
    [J]. RADIATION PROTECTION DOSIMETRY, 2016, 169 (1-4) : 371 - 377
  • [5] Optimization of image quality and dose in adult and pediatric chest radiography via Monte Carlo simulation and experimental methods
    Mendes, Hitalo R.
    Silva, Julio C.
    Marcondes, Mariana
    Tomal, Alessandra
    [J]. RADIATION PHYSICS AND CHEMISTRY, 2022, 201
  • [6] Dose reduction in digital chest radiography and perceived image quality
    Kroft, L. J. M.
    Veldkamp, W. J. H.
    Mertens, B. J. A.
    Van Delft, J-P A.
    Geleijns, J.
    [J]. BRITISH JOURNAL OF RADIOLOGY, 2007, 80 (960): : 984 - 988
  • [7] Optimization of dose and image quality in pediatrics chest digital radiography
    Deevband, Mohammad Reza
    Rahmani, Fereshteh
    Bardar, Meisam Ebrahimi
    Ghorbani, Mahdi
    [J]. JOURNAL OF MEDICAL IMAGING AND RADIATION SCIENCES, 2021, 52 (03) : 443 - 449
  • [8] Analyses of patient dose and image quality for chest digital radiography
    Tsai, H. Y.
    Yang, C. H.
    Huang, K. M.
    Li, M. J.
    Tung, C. J.
    [J]. RADIATION MEASUREMENTS, 2010, 45 (3-6) : 722 - 725
  • [9] Digital chest radiography image quality assessment with dose reduction
    Grewal, R. K.
    Young, N.
    Collins, L.
    Karunaratne, N.
    Sabharwal, R.
    [J]. AUSTRALASIAN PHYSICAL & ENGINEERING SCIENCES IN MEDICINE, 2012, 35 (01) : 71 - 80
  • [10] Digital chest radiography image quality assessment with dose reduction
    R. K. Grewal
    N. Young
    L. Collins
    N. Karunaratne
    R. Sabharwal