Verification of phantom accuracy using a Monte Carlo simulation: bone scintigraphy chest phantom

被引:3
|
作者
Ito, Toshimune [1 ]
Tsuchikame, Hirotatsu [2 ]
Ichikawa, Hajime [3 ,4 ]
Onoguchi, Masahisa [4 ]
Okuda, Koichi [5 ]
Shibutani, Takayuki [4 ]
Yokotsuka, Noriyo [1 ]
Tomizawa, Hiroshi [1 ]
机构
[1] Teikyo Univ, Fac Med Technol, Dept Radiol Technol, Itabashi Ku, 2-11-1 Kaga, Tokyo 1738605, Japan
[2] Saiseikai Yokohamashi Tobu Hosp, Dept Radiol, Tsurumi Ku, 3-6-1 Shimosueyoshi, Yokohama, Kanagawa 2300012, Japan
[3] Toyohashi Municipal Hosp, Dept Radiol, 50 Aza,Aotaka Cho, Toyohashi, Aichi 4418570, Japan
[4] Kanazawa Univ, Grad Sch Med Sci, Dept Quantum Med Technol, 5-11-80 Kodatsuno, Kanazawa, Ishikawa 9200942, Japan
[5] Kanazawa Med Univ, Dept Phys, 1-1 Daigaku, Kahoku, Ishikawa 9200293, Japan
关键词
Monte Carlo simulation; Bone scintigraphy; SIMIND; Reconstruction methods; Correction methods; SPECT/CT;
D O I
10.1007/s12194-021-00631-5
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
We aimed to compare the measurement and simulation data of bone scintigraphy of a chest phantom using a Monte Carlo simulation to verify the accuracy of the simulated data. The SIM2 bone phantom was enclosed using 300 kBq/mL of technetium-99 m (Tc-99m) to represent the bone tumor and 50 kBq/mL of Tc-99m to represent normal bone. Projection data were obtained using single-photon emission computed tomography (SPECT). Simulated projection data were constructed based on CT data. The contrast ratio, recovery coefficient (RC), % coefficient variation (CV), and power spectrum density (PSD) of each part were calculated from the reconstructed data. The contrast ratio and RC were equal between the actual and simulated data. Higher % CV values were noted for soft tissue than for normal bone. The PSD was equal for all frequency band ranges. Our results prove the utility of the Monte Carlo simulation for verifying various data using phantoms.
引用
收藏
页码:336 / 344
页数:9
相关论文
共 50 条
  • [1] Verification of phantom accuracy using a Monte Carlo simulation: bone scintigraphy chest phantom
    Toshimune Ito
    Hirotatsu Tsuchikame
    Hajime Ichikawa
    Masahisa Onoguchi
    Koichi Okuda
    Takayuki Shibutani
    Noriyo Yokotsuka
    Hiroshi Tomizawa
    [J]. Radiological Physics and Technology, 2021, 14 : 336 - 344
  • [2] Verification of the Simplified Monte Carlo Method for Simulation in An Inhomogeneous Phantom
    Mizutani, S.
    Takada, Y.
    Kohno, R.
    Hotta, K.
    Akimoto, T.
    [J]. MEDICAL PHYSICS, 2015, 42 (06) : 3523 - 3523
  • [3] Monte Carlo simulation of a mammographic test phantom
    Hunt, RA
    Dance, DR
    Pachoud, M
    Carlsson, GA
    Sandborg, M
    Ullman, G
    Verdun, FR
    [J]. RADIATION PROTECTION DOSIMETRY, 2005, 114 (1-3) : 432 - 435
  • [4] Hybrid Microscale Phantom of Kidney for Monte Carlo Simulation
    Jabbary M.
    [J]. Mathematical Models and Computer Simulations, 2022, 14 (6) : 1032 - 1043
  • [5] Simulation of a quality control jaszczak phantom with SIMIND Monte Carlo and adding the phantom as an accessory to the program
    Islamian, Jalil Pirayesh
    Toossi, Mohammad Taghi Bahreyni
    Momennezhad, Mehdi
    Naseri, Shahrokh
    Ljungberg, Michael
    [J]. Iranian Journal of Medical Physics, 2012, 9 (2 A): : 135 - 140
  • [6] Dose Verification of SRS Monte Carlo Plan with a Moving Anthropomorphic Phantom
    Lo, A.
    Ho, A.
    Dieterich, S.
    [J]. MEDICAL PHYSICS, 2010, 37 (06) : 3288 - +
  • [7] Development of the Computational Human Thoracic Phantom and Estimation of the Organ Absorbed Dose in the Chest Radiography Using Monte Carlo Simulation
    Sato, N.
    Fujibuchi, T.
    Yabituchi, H.
    [J]. MEDICAL PHYSICS, 2017, 44 (06)
  • [8] GATE Monte Carlo Simulation of GE Discovery 600 and a Uniformity Phantom
    Sheen, Heesoon
    Im, Ki Chun
    Choi, Yong
    Shin, Hanback
    Han, Youngyih
    Chung, Kwangzoo
    Cho, Junsang
    Ahn, Sang Hee
    [J]. JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2014, 65 (11) : 1802 - 1808
  • [9] Fast Monte Carlo simulation on a voxelized human phantom deformed to a patient
    Bueno, G.
    Deniz, O.
    Carrascosa, C. B.
    Delgado, J. M.
    Brualla, L.
    [J]. MEDICAL PHYSICS, 2009, 36 (11) : 5162 - 5174
  • [10] The Development of a Tetrahedral Phantom and Its Monte Carlo Simulation for Proton Therapy
    Chao, T. C.
    Chang, H. K.
    Lee, C. C.
    Tung, C. J.
    [J]. MEDICAL PHYSICS, 2017, 44 (06)