Influence of Different Implants on the Biomechanical Behavior of a Tooth-Implant Fixed Partial Dentures: A Three-Dimensional Finite Element Analysis

被引:4
|
作者
Lencioni, Karina Albino [1 ]
Noritomi, Pedro Yoshito [2 ]
Macedo, Ana Paula [1 ]
Ribeiro, Ricardo Faria [1 ]
de Almeida, Rossana Pereira [1 ]
机构
[1] Univ Sao Paulo, Dent Sch Ribeirao Preto, Dept Dent Mat & Prosthodont, Ribeirao Preto, SP, Brazil
[2] Renato Archer Informat Technol Ctr CTI, Campinas, SP, Brazil
基金
巴西圣保罗研究基金会;
关键词
biomechanics; implants; tooth-implant supported fixed partial dentures; PHOTOELASTIC STRESS-ANALYSIS; PERIODONTAL-LIGAMENT; CONNECTED PROSTHESES; EXTERNAL HEXAGON; TEETH; BONE; DESIGN; SYSTEM; FORCES;
D O I
10.1563/aaid-joi-D-18-00314
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
This study analyzed the biomechanical behavior of rigid and nonrigid tooth-implant supported fixed partial dentures. Different implants were used to observe the load distribution over teeth, implants, and adjacent bone using three-dimensional finite element analysis. A simulation of tooth loss of the first and second right molars was created with an implant placed in the second right molar and a prepared tooth with simulated periodontal ligament (PDL) in the second right premolar. Configurations of two types of implants and their respective abutments-external hexagon (EX) and Morse taper (MT)-were transformed into a 3D format. Metal-ceramic fixed partial dentures were constructed with rigid and nonrigid connections. Mesh generation and data processing were performed on the 3D finite element analysis (FEA) results. Static loading of 50 N (premolar) and 100 N (implant) were applied. When an EX implant was used, with a rigid or nonrigid connection, there was intrusion of the tooth in the distal direction with flexion of the periodontal ligament. Tooth intrusion did not occur when the MT implant was used independent of a rigid or nonrigid connection. The rigid or nonrigid connection resulted in a higher incidence of compressive forces at the cortical bone as well as stress in the abutment/pontic area, regardless of whether EX or MT implants were used. MT implants have a superior biomechanical performance in tooth-implant supported fixed partial dentures. This prevents intrusion of the tooth independent of the connection. Both types of implants studied caused a greater tendency of compressive forces at the crestal area.
引用
收藏
页码:27 / 34
页数:8
相关论文
共 50 条
  • [1] The Influence of Bone Quality on the Biomechanical Behavior of a Tooth-Implant Fixed Partial Denture: A Three-Dimensional Finite Element Analysis
    Tsouknidas, Alexander
    Giannopoulos, Dimitrios
    Savvakis, Savvas
    Michailidis, Nikolaos
    Lympoudi, Evdokia
    Fytanidis, Dimitrios
    Pissiotis, Argirios
    Michalakis, Konstantinos
    [J]. INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2016, 31 (06) : E143 - E154
  • [2] Influence of Connector Design on Displacement and Micromotion in Tooth-Implant Fixed Partial Dentures Using Different Lengths and Diameters: A Three-Dimensional Finite Element Study
    Mously, Hisham A.
    Naguib, Ghada H.
    Hashem, Abou Bakr Hossam
    Abougazia, Ahmed O.
    Binmahfooz, Abdulelah M.
    Hamed, Mohamed T.
    [J]. MATERIALS, 2024, 17 (17)
  • [3] Biomechanical Behavior of Tooth-Implant Supported Prostheses With Different Implant Connections: A Nonlinear Finite Element Analysis
    de Paula, Gustavo Assis
    Silva, Guilherme Carvalho
    Vilaca, Enio Lacerda
    Cornacchia, Tulimar Machado
    de Magalhaes, Claudia Silami
    Moreira, Allyson Nogueira
    [J]. IMPLANT DENTISTRY, 2018, 27 (03) : 294 - 302
  • [4] Three-dimensional finite element analysis comparative model of tooth-implant nonrigid fixation
    Muradyan, Tigran A.
    Muradyan, Nshan A.
    Verlinski, Sergey V.
    Poghosyan, Anna Yu
    [J]. SIMULATION-TRANSACTIONS OF THE SOCIETY FOR MODELING AND SIMULATION INTERNATIONAL, 2021, 97 (04): : 239 - 246
  • [5] Three-dimensional finite element analysis of the retention of fixed partial dentures.
    Augereau D.
    Renault P.
    Pierrisnard L.
    Barquins M.
    [J]. Clinical Oral Investigations, 1997, 1 (3) : 141 - 146
  • [6] Three-dimensional finite element stress analysis of different core materials in maxillary implant-supported fixed partial dentures
    Ozen, Julide
    Caglar, Alper
    Beydemir, Bedri
    Aydin, Cemal
    Dalkiz, Mehmet
    [J]. QUINTESSENCE INTERNATIONAL, 2007, 38 (06): : E355 - E363
  • [7] Influence of Mechanical Properties of Dental Implants on Biomechanical Behavior: A Three-Dimensional Finite Element Analysis
    Goradia, Youcef
    Gouasmi, Sadek
    Reffaas, Sid Ahmed
    [J]. JOURNAL OF BIOMIMETICS BIOMATERIALS AND BIOMEDICAL ENGINEERING, 2024, 64 : 39 - 54
  • [8] Three-dimensional finite element analysis of implant-assisted removable partial dentures
    Eom, Ju-Won
    Lim, Young-Jun
    Kim, Myung-Joo
    Kwon, Ho-Beom
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 2017, 117 (06): : 735 - 742
  • [9] Three-dimensional finite element analysis of anterior fixed partial denture supported by implants with different materials
    Xie, Bingqing
    Chen, Junliang
    Zhao, Tianqi
    Shen, Jie
    Doersam, Istabrak
    He, Yun
    [J]. ANNALS OF ANATOMY-ANATOMISCHER ANZEIGER, 2022, 243
  • [10] Tooth-implant and implant supported fixed partial dentures:: A 10-year report
    Gunne, J
    Åstrand, P
    Lindh, T
    Borg, K
    Olsson, M
    [J]. INTERNATIONAL JOURNAL OF PROSTHODONTICS, 1999, 12 (03) : 216 - 221