Influence of Different Implants on the Biomechanical Behavior of a Tooth-Implant Fixed Partial Dentures: A Three-Dimensional Finite Element Analysis

被引:4
|
作者
Lencioni, Karina Albino [1 ]
Noritomi, Pedro Yoshito [2 ]
Macedo, Ana Paula [1 ]
Ribeiro, Ricardo Faria [1 ]
de Almeida, Rossana Pereira [1 ]
机构
[1] Univ Sao Paulo, Dent Sch Ribeirao Preto, Dept Dent Mat & Prosthodont, Ribeirao Preto, SP, Brazil
[2] Renato Archer Informat Technol Ctr CTI, Campinas, SP, Brazil
基金
巴西圣保罗研究基金会;
关键词
biomechanics; implants; tooth-implant supported fixed partial dentures; PHOTOELASTIC STRESS-ANALYSIS; PERIODONTAL-LIGAMENT; CONNECTED PROSTHESES; EXTERNAL HEXAGON; TEETH; BONE; DESIGN; SYSTEM; FORCES;
D O I
10.1563/aaid-joi-D-18-00314
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
This study analyzed the biomechanical behavior of rigid and nonrigid tooth-implant supported fixed partial dentures. Different implants were used to observe the load distribution over teeth, implants, and adjacent bone using three-dimensional finite element analysis. A simulation of tooth loss of the first and second right molars was created with an implant placed in the second right molar and a prepared tooth with simulated periodontal ligament (PDL) in the second right premolar. Configurations of two types of implants and their respective abutments-external hexagon (EX) and Morse taper (MT)-were transformed into a 3D format. Metal-ceramic fixed partial dentures were constructed with rigid and nonrigid connections. Mesh generation and data processing were performed on the 3D finite element analysis (FEA) results. Static loading of 50 N (premolar) and 100 N (implant) were applied. When an EX implant was used, with a rigid or nonrigid connection, there was intrusion of the tooth in the distal direction with flexion of the periodontal ligament. Tooth intrusion did not occur when the MT implant was used independent of a rigid or nonrigid connection. The rigid or nonrigid connection resulted in a higher incidence of compressive forces at the cortical bone as well as stress in the abutment/pontic area, regardless of whether EX or MT implants were used. MT implants have a superior biomechanical performance in tooth-implant supported fixed partial dentures. This prevents intrusion of the tooth independent of the connection. Both types of implants studied caused a greater tendency of compressive forces at the crestal area.
引用
收藏
页码:27 / 34
页数:8
相关论文
共 50 条
  • [31] A three-dimensional finite element study on the biomechanical behavior of an FGBM dental implant in surrounding bone
    Yang, Jie
    Xiang, Hong-Jun
    [J]. JOURNAL OF BIOMECHANICS, 2007, 40 (11) : 2377 - 2385
  • [32] Influence of Socket-shield technique on the biomechanical response of dental implant: three-dimensional finite element analysis
    Mendes Tribst, Joao Paulo
    de Oliveira Dal Piva, Amanda Maria
    Souto Borges, Alexandre Luiz
    Bottino, Marco Antonio
    [J]. COMPUTER METHODS IN BIOMECHANICS AND BIOMEDICAL ENGINEERING, 2020, 23 (06) : 224 - 231
  • [33] Influence of implant number on the biomechanical behaviour of mandibular implant-retained/supported overdentures: A three-dimensional finite element analysis
    Liu, Jingyin
    Pan, Shaoxia
    Dong, Jing
    Mo, Zhongjun
    Fan, Yubo
    Feng, Hailan
    [J]. JOURNAL OF DENTISTRY, 2013, 41 (03) : 241 - 249
  • [34] Biomechanical analysis of rigid and non-rigid connection with implant abutment designs for tooth-implant supported prosthesis: A finite element analysis
    Huang, Yen-Chang
    Ding, Shinn-Jyh
    Yuan, Cadmus
    Yan, Min
    [J]. JOURNAL OF DENTAL SCIENCES, 2022, 17 (01) : 490 - 499
  • [35] Biomechanical Analysis of Titanium Dental Implants in the All-on-4 Treatment with Different Implant-Abutment Connections: A Three-Dimensional Finite Element Study
    Wang, Pei-Shuang
    Tsai, Ming-Hsu
    Wu, Yu-Ling
    Chen, Hung-Shyong
    Lei, Yao-Ning
    Wu, Aaron Yu-Jen
    [J]. JOURNAL OF FUNCTIONAL BIOMATERIALS, 2023, 14 (10)
  • [36] The Effect of Implant Length and Diameter on Stress Distribution of Tooth-Implant and Implant Supported Fixed Prostheses: An In Vitro Finite Element Analysis Study
    Naguib, Ghada H.
    Hashem, Abou Bakr H.
    Natto, Zuhair S.
    Abougazia, Ahmed O.
    Mously, Hisham A.
    Hamed, Mohamed T.
    [J]. JOURNAL OF ORAL IMPLANTOLOGY, 2023, 49 (01) : 46 - 54
  • [37] Selection of the implant thread pitch for optimal biomechanical properties: A three-dimensional finite element analysis
    Kong, Liang
    Zhao, Yunzhuan
    Hu, Kaijin
    Li, Dehua
    Zhou, Hongzhi
    Wu, Ziyan
    Liu, Baolin
    [J]. ADVANCES IN ENGINEERING SOFTWARE, 2009, 40 (07) : 474 - 478
  • [38] Biomechanical optimization of the diameter of distraction screw in distraction implant by three-dimensional finite element analysis
    Lu, Songhe
    Li, Tao
    Zhang, Yongqiang
    Lu, Chunlei
    Sun, Yingying
    Zhang, Junrui
    Xu, Dezhong
    [J]. COMPUTERS IN BIOLOGY AND MEDICINE, 2013, 43 (11) : 1949 - 1954
  • [39] Selection of the implant transgingival height for optimal biomechanical properties: a three-dimensional finite element analysis
    Sun, Yingying
    Kong, Liang
    Hu, Kaijin
    Xie, Cheng
    Zhou, Hongzhi
    Liu, Yanpu
    Liu, Baolin
    [J]. BRITISH JOURNAL OF ORAL & MAXILLOFACIAL SURGERY, 2009, 47 (05): : 393 - 398
  • [40] Selection of the distraction implant length with improved biomechanical properties by three-dimensional finite element analysis
    Gao, J.
    Li, T.
    Hou, X. -C.
    Wang, Z.
    Kong, L.
    Chen, J. -H.
    [J]. JOURNAL OF ORAL REHABILITATION, 2011, 38 (04) : 270 - 277