摘要
Statement of problem. Whether the implant abutment in implant-assisted removable partial dentures (IARPDs) functions as a natural removable partial denture (RPD) tooth abutment is unknown. Purpose. The purpose of this 3-dimensional finite element study was to analyze the biomechanical behavior of implant crown, bone, RPD, and IARPD. Material and methods. Finite element models of the partial maxilla, teeth, and prostheses were generated on the basis of a patient's computed tomographic data. The teeth, surveyed crowns, and RPDs were created in the model. With the generated components, four 3-dimensional finite element models of the partial maxilla were constructed: tooth-supported RPD (TB), implant supported RPD (IB), tooth-tissue-supported RPD (TT), and implant-tissue-supported RPD (IT) models. Oblique loading of 300 N was applied on the crowns and denture teeth. The von Mises stress and displacement of the denture abutment tooth and implant system were identified. Results. The highest von Mises stress values of both IARPDs occurred on the implants, while those of both natural tooth RPDs occurred on the frameworks of the RPDs. The highest von Mises stress of model IT was about twice that of model IB, while the value of model TT was similar to that of model TB. The maximum displacement was greater in models TB and TT than in models IB and IT. Among the 4 models, the highest maximum displacement value was observed in the model TT and the lowest value was in the model IB. Conclusions. Finite element analysis revealed that the stress distribution pattern of the IARPDs was different from that of the natural tooth RPDs and the stress distribution of implant-supported RPD was different from that of implant-tissue-supported RPD. When implants are used for RPD abutments, more consideration concerning the RPD design and the number or location of the implant is necessary.
引用
收藏
页码:735 / 742
页数:8
相关论文
共 50 条
  • [1] Influence of Implant Position in Implant-Assisted Removable Partial Denture: A Three-Dimensional Finite Element Analysis
    Ortiz-Puigpelat, Octavi
    Lazaro-Abdulkarim, Aida
    de Medrano-Rene, Javier-Maria
    Gargallo-Albiol, Jordi
    Cabratosa-Termes, Josep
    Hernandez-Alfaro, Federico
    [J]. JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2019, 28 (02): : E675 - E681
  • [2] Finite element analysis of implant-assisted removable partial dentures: Framework design considerations
    Shahmiri, Reza
    Das, Raj
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 2017, 118 (02): : 177 - 186
  • [3] Finite Element Analysis of an Implant-Assisted Removable Partial Denture
    Shahmiri, Reza
    Aarts, John M.
    Bennani, Vincent
    Atieh, Momen A.
    Swain, Michael V.
    [J]. JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2013, 22 (07): : 550 - 555
  • [4] Impact of implant location on load distribution of implant-assisted removable partial dentures: a review of in vitro model and finite-element analysis studies
    Ichikawa, Hiromi
    Yoda, Nobuhiro
    Ogawa, Toru
    Iwamoto, Maya
    Kawata, Tetsuo
    Egusa, Hiroshi
    Sasaki, Keiichi
    [J]. INTERNATIONAL JOURNAL OF IMPLANT DENTISTRY, 2023, 9 (01)
  • [5] Impact of implant location on load distribution of implant-assisted removable partial dentures: a review of in vitro model and finite-element analysis studies
    Hiromi Ichikawa
    Nobuhiro Yoda
    Toru Ogawa
    Maya Iwamoto
    Tetsuo Kawata
    Hiroshi Egusa
    Keiichi Sasaki
    [J]. International Journal of Implant Dentistry, 9
  • [6] Mechanical analysis of the effects of implant position and abutment height on implant-assisted removable partial dentures
    Ohyama, Tetsuo
    Nakabayashi, Shinya
    Yasuda, Hiroyasu
    Kase, Takeshi
    Namaki, Shunsuke
    [J]. JOURNAL OF PROSTHODONTIC RESEARCH, 2020, 64 (03) : 340 - 345
  • [7] Mechanical Evaluation of Implant-Assisted Removable Partial Dentures in Kennedy Class I Patients: Finite Element Design Considerations
    Messias, Ana
    Neto, Maria A.
    Amaro, Ana M.
    Lopes, Vitor M.
    Nicolau, Pedro
    [J]. APPLIED SCIENCES-BASEL, 2021, 11 (02): : 1 - 18
  • [8] Clinical Outcomes of Implant-Assisted Removable Partial Dentures According to Implant Strategic Position
    Yi, Yuseung
    Heo, Seong-Joo
    Koak, Jai-Young
    Kim, Seong-Kyun
    [J]. JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2023, 32 (05): : 401 - 410
  • [9] Effect of Number and Location on Stress Distribution of Mini Dental Implant-Assisted Mandibular Kennedy Class I Removable Partial Denture: Three-Dimensional Finite Element Analysis
    Jia-mahasap, Wissanee
    Rungsiyakull, Chaiy
    Bumrungsiri, Wipahatpong
    Sirisereephap, Natthaphorn
    Rungsiyakull, Pimduen
    [J]. INTERNATIONAL JOURNAL OF DENTISTRY, 2022, 2022
  • [10] Retrospective clinical evaluation of implant-assisted removable partial dentures combined with implant surveyed prostheses
    Oh, You-Kyoung
    Bae, Eun-Bin
    Huh, Jung-Bo
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 2021, 126 (01): : 76 - 82