Three-dimensional finite element analysis comparative model of tooth-implant nonrigid fixation

被引:1
|
作者
Muradyan, Tigran A. [1 ]
Muradyan, Nshan A. [1 ]
Verlinski, Sergey V. [2 ]
Poghosyan, Anna Yu [1 ]
机构
[1] Yerevan State Med Univ, Dept Oral & Maxillofacial Surg, 60 Abovyan Str, Yerevan 0025, Armenia
[2] Natl Polytech Univ Armenia, Mech & Machine Sci, Yerevan, Armenia
关键词
Three-dimensional modeling; finite element analysis; implant prosthesis; strain; stress analysis;
D O I
10.1177/0037549720972781
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
Connecting implants with teeth is sometimes considered for the support of prostheses in partial edentulism, especially in periodontally compromised and surgical treated patients. The aim of this study is the presentation of a model of tooth-implant nonrigid fixation in comparison with implant-implant and implant-tooth rigid fixation by three-dimensional (3D) finite element analysis. As a model, a situation with a mandibular second premolar and two molars edentulism was selected. Two implantation options with three prosthetics designs were considered. The comparative analysis of stress and strain distribution values under vertical 100 and 200 N loading was performed. The highest peri-implant crestal bone stress distribution was observed in the model with the implant-tooth rigid fixation with 200 N vertical loading with results of 136.56 MPa. In the model with implant-tooth nonrigid fixation, the maximum strain value was observed in the tooth-connector zone and the stress distribution was higher in the connectors and the prosthesis pontic zone, with a maximal value of 27.77 MPa. The design of a tooth-implant fixed denture could be suggested as a method of choice for rehabilitation of the posterior edentulous segment in cases when only one distal implant could be installed. Further clinical research is required to obtain reliable validation data for the proposed method.
引用
收藏
页码:239 / 246
页数:8
相关论文
共 50 条
  • [1] The Influence of Bone Quality on the Biomechanical Behavior of a Tooth-Implant Fixed Partial Denture: A Three-Dimensional Finite Element Analysis
    Tsouknidas, Alexander
    Giannopoulos, Dimitrios
    Savvakis, Savvas
    Michailidis, Nikolaos
    Lympoudi, Evdokia
    Fytanidis, Dimitrios
    Pissiotis, Argirios
    Michalakis, Konstantinos
    [J]. INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2016, 31 (06) : E143 - E154
  • [2] Influence of Different Implants on the Biomechanical Behavior of a Tooth-Implant Fixed Partial Dentures: A Three-Dimensional Finite Element Analysis
    Lencioni, Karina Albino
    Noritomi, Pedro Yoshito
    Macedo, Ana Paula
    Ribeiro, Ricardo Faria
    de Almeida, Rossana Pereira
    [J]. JOURNAL OF ORAL IMPLANTOLOGY, 2020, 46 (01) : 27 - 34
  • [3] A mimic osseointegrated implant model for three-dimensional finite element analysis
    Akagawa, Y
    Sato, Y
    Teixeira, ER
    Shindoi, N
    Wadamoto, M
    [J]. JOURNAL OF ORAL REHABILITATION, 2003, 30 (01) : 41 - 45
  • [4] A three-dimensional finite element analysis with various implant designs
    Yoo, Dong-Ki
    Heo, Seong-Joo
    Koak, Jai-Young
    Kim, Seong-Kyun
    Lim, Young-Jun
    Kim, Sung-Hun
    Han, Chong-Hyun
    [J]. ASBM7: ADVANCED BIOMATERIALS VII, 2007, 342-343 : 885 - +
  • [5] Three-dimensional finite element analysis of platform switched implant
    Moon, Se-Young
    Lim, Young-Jun
    Kim, Myung-Joo
    Kwon, Ho-Beom
    [J]. JOURNAL OF ADVANCED PROSTHODONTICS, 2017, 9 (01): : 31 - 37
  • [6] Biomechanical Behavior of Tooth-Implant Supported Prostheses With Different Implant Connections: A Nonlinear Finite Element Analysis
    de Paula, Gustavo Assis
    Silva, Guilherme Carvalho
    Vilaca, Enio Lacerda
    Cornacchia, Tulimar Machado
    de Magalhaes, Claudia Silami
    Moreira, Allyson Nogueira
    [J]. IMPLANT DENTISTRY, 2018, 27 (03) : 294 - 302
  • [7] Three Dimensional Mathematical Model of Tooth for Finite Element Analysis
    Puskar, Tatjana
    Vasiljevic, Darko
    Markovic, Dubravka
    Jevremovic, Danimir
    Pantelic, Dejan
    Savic-Sevic, Svetlana
    Muric, Branka
    [J]. SRPSKI ARHIV ZA CELOKUPNO LEKARSTVO, 2010, 138 (1-2) : 19 - 25
  • [8] Influence of Connector Design on Displacement and Micromotion in Tooth-Implant Fixed Partial Dentures Using Different Lengths and Diameters: A Three-Dimensional Finite Element Study
    Mously, Hisham A.
    Naguib, Ghada H.
    Hashem, Abou Bakr Hossam
    Abougazia, Ahmed O.
    Binmahfooz, Abdulelah M.
    Hamed, Mohamed T.
    [J]. MATERIALS, 2024, 17 (17)
  • [9] Comparative Three-Dimensional Finite Element Analysis on Miniplate and Lag Screw Fixation to Symphysis Fractures
    Ertem, Sinan Yasin
    [J]. JOURNAL OF CRANIOFACIAL SURGERY, 2020, 31 (04) : 983 - 988
  • [10] Biomechanical evaluation of bridge span with three implant abutment designs and two connectors for tooth-implant supported prosthesis: A finite element analysis
    Huang, Ling-Shiuan
    Huang, Yen-Chang
    Yuan, Cadmus
    Ding, Shinn-Jyh
    Yan, Min
    [J]. JOURNAL OF DENTAL SCIENCES, 2023, 18 (01) : 248 - 263