Phenylboronic acid immunoaffinity reactor coupled with flow injection chemiluminescence for determination of α-fetoprotein

被引:40
|
作者
Wu, Yafeng [1 ]
Zhuang, Yafeng [2 ]
Liu, Songqin [1 ]
He, Lin [3 ]
机构
[1] Southeast Univ, Sch Chem & Chem Engn, Jiangsu Prov Key Lab Biomat & Biodevices, Nanjing 210096, Peoples R China
[2] Changzhou Inst Technol, Dept Chem, Changzhou 213022, Peoples R China
[3] N Carolina State Univ, Dept Chem, Raleigh, NC 27695 USA
基金
中国国家自然科学基金;
关键词
3-Aminophenylboronic acid; alpha-Fetoprotein; Immunoaffinity reactor; Regeneration; Flow injection chemiluminescence;
D O I
10.1016/j.aca.2008.10.010
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A reusable and sensitive immunoassay based on phenylboronic acid immunoaffinity reactor in combination with flow injection chemiluminescence (CL) for determination of glycoprotein was described. The reactor was fabricated by immobilizing 3-aminophenylboronic acid (APBA) on glass microbeads with gamma-glycidoxypropyltrimethoxysilane (GPMS) as linkage. The a-fetoprotein (AFP) could be easily immobilized on the APBA coated beads through sugar-boronic interaction. After an off-line incubation, the mixture of the analyte AFP with horseradish peroxidase-labeled AFP antibody (HRP-anti-AFP) was injected into the reactor. This led the trapping of free HRP-anti-AFP by the surface coated AFP on glass beads. The trapped HRP-anti-AFP was detected by chemiluminescence due to its sensitizing effect on the reaction of luminol and hydrogen peroxide. Under optimal conditions, the chemiluminescent signal was proportional to AFP concentration in the range of 10-100 ng mL(-1). The whole assay process including regeneration of the reactor could be completed within 31 min. The proposed system showed acceptable detection and fabrication reproducibility, and the results obtained with the present method were in acceptable agreement with those from parallel single-analyte test of practical clinical sera. The described method enabled a low-cost, time saving and was potential to detect the serum AFP level in clinical diagnosis. (C) 2008 Elsevier B.V. All rights reserved.
引用
收藏
页码:186 / 193
页数:8
相关论文
共 50 条
  • [1] Immunosensing system for α-fetoprotein through boronate immunoaffinity column in combination with flow injection chemiluminescence
    Wu, Yafeng
    Liu, Songqin
    ANALYST, 2009, 134 (02) : 230 - 235
  • [2] Determination of bismuth by flow injection coupled chemiluminescence reaction
    Fan, Shun-Li
    Wu, Zhi-Hao
    Lihua Jianyan: Huaxue Fence/Physical Testing and Chemical Analysis Part B:Chemical Analysis, 2003, 39 (07):
  • [3] Determination of gallium by flow injection coupled chemiluminescence reaction
    Li, WH
    Zhang, ZJ
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2001, 29 (12) : 1447 - 1449
  • [4] Flow injection chemiluminescence determination of uric acid
    Zhang, DJ
    Huang, YM
    Zhang, ZJ
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2001, 29 (04) : 446 - 449
  • [5] Flow injection determination of humic acid with chemiluminescence detection
    Tian, YH
    Song, QJ
    Hua, ZZ
    ANALYTICAL LETTERS, 2005, 38 (14) : 2439 - 2447
  • [6] Determination of hydrogen peroxide by micro-flow injection-chemiluminescence using a coupled flow cell reactor chemiluminometer
    Nozaki, O
    Kawamoto, H
    LUMINESCENCE, 2000, 15 (03) : 137 - 142
  • [7] Determination of tyrosine using flow injection analysis coupled with chemiluminescence detection
    Zhang, XY
    Fan, XD
    Gao, X
    Zhang, FY
    Zhang, Q
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2004, 32 (12) : 1693 - 1693
  • [8] Determination of ascorbic acid by flow-injection chemiluminescence method
    Yu, J.
    Zhang, C.
    Tan, Y.
    Ge, S.
    Dai, P.
    Zha, Y.
    LUMINESCENCE, 2008, 23 (02) : 107 - 107
  • [9] Determination of pipernidic acid by flow injection analysis with chemiluminescence detection
    Li, LQ
    Wu, YY
    Feng, ML
    Lü, JR
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2002, 30 (02) : 169 - 171
  • [10] Determination of ascorbic acid by flow injection chemiluminescence suppression method
    Li, F
    Zhang, WY
    Zhu, GY
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2000, 28 (12) : 1523 - 1526