Phenylboronic acid immunoaffinity reactor coupled with flow injection chemiluminescence for determination of α-fetoprotein

被引:40
|
作者
Wu, Yafeng [1 ]
Zhuang, Yafeng [2 ]
Liu, Songqin [1 ]
He, Lin [3 ]
机构
[1] Southeast Univ, Sch Chem & Chem Engn, Jiangsu Prov Key Lab Biomat & Biodevices, Nanjing 210096, Peoples R China
[2] Changzhou Inst Technol, Dept Chem, Changzhou 213022, Peoples R China
[3] N Carolina State Univ, Dept Chem, Raleigh, NC 27695 USA
基金
中国国家自然科学基金;
关键词
3-Aminophenylboronic acid; alpha-Fetoprotein; Immunoaffinity reactor; Regeneration; Flow injection chemiluminescence;
D O I
10.1016/j.aca.2008.10.010
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A reusable and sensitive immunoassay based on phenylboronic acid immunoaffinity reactor in combination with flow injection chemiluminescence (CL) for determination of glycoprotein was described. The reactor was fabricated by immobilizing 3-aminophenylboronic acid (APBA) on glass microbeads with gamma-glycidoxypropyltrimethoxysilane (GPMS) as linkage. The a-fetoprotein (AFP) could be easily immobilized on the APBA coated beads through sugar-boronic interaction. After an off-line incubation, the mixture of the analyte AFP with horseradish peroxidase-labeled AFP antibody (HRP-anti-AFP) was injected into the reactor. This led the trapping of free HRP-anti-AFP by the surface coated AFP on glass beads. The trapped HRP-anti-AFP was detected by chemiluminescence due to its sensitizing effect on the reaction of luminol and hydrogen peroxide. Under optimal conditions, the chemiluminescent signal was proportional to AFP concentration in the range of 10-100 ng mL(-1). The whole assay process including regeneration of the reactor could be completed within 31 min. The proposed system showed acceptable detection and fabrication reproducibility, and the results obtained with the present method were in acceptable agreement with those from parallel single-analyte test of practical clinical sera. The described method enabled a low-cost, time saving and was potential to detect the serum AFP level in clinical diagnosis. (C) 2008 Elsevier B.V. All rights reserved.
引用
收藏
页码:186 / 193
页数:8
相关论文
共 50 条
  • [11] Determination of amino acid by reverse flow-injection chemiluminescence
    Lang, HY
    Cai, J
    Li, YR
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2003, 31 (10) : 1274 - 1274
  • [12] Determination of uric acid by chemiluminescence-flow injection analysis
    Wu, YY
    Li, LQ
    Geng, Z
    Liu, QG
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 1999, 27 (05) : 543 - 546
  • [13] DETERMINATION OF CINNAMIC ACID IN HUMAN URINE BY FLOW INJECTION CHEMILUMINESCENCE
    Fan, Xuemei
    Wang, Shumin
    Su, Zhikui
    Chen, Fengying
    Liu, Yanfeng
    Liu, Ping
    Zheng, Xingwang
    Cui, Fengling
    QUIMICA NOVA, 2011, 34 (08): : 1405 - 1408
  • [14] Chemiluminescence determination of folic acid by a flow injection analysis assembly
    Wabaidur, Saikh Mohammad
    Alam, Seikh Mafiz
    Lee, Sang Hak
    Alothman, Zeid Abdullah
    Eldesoky, Gaber E.
    SPECTROCHIMICA ACTA PART A-MOLECULAR AND BIOMOLECULAR SPECTROSCOPY, 2013, 105 : 412 - 417
  • [15] Determination of hydrogen peroxide by flow injection-chemiluminescence using a novel flow-cell reactor in a chemiluminescence detector
    Kawamoto, H
    Nozaki, O
    BUNSEKI KAGAKU, 1999, 48 (05) : 471 - 476
  • [16] Noncompetitive enzyme immunoassay for α-fetoprotein using flow injection chemiluminescence
    Lin, JH
    Yan, F
    Ju, HX
    APPLIED BIOCHEMISTRY AND BIOTECHNOLOGY, 2004, 117 (02) : 93 - 102
  • [17] Flow injection chemiluminescence immunoassay for 17β-estradiol using an immunoaffinity column
    Shuhao Wang
    Shilei Lin
    Lingyun Du
    Huisheng Zhuang
    Analytical and Bioanalytical Chemistry, 2006, 384 : 1186 - 1190
  • [18] Flow injection chemiluminescence immunoassay for 17β-estradiol using an immunoaffinity column
    Wang, SH
    Lin, SL
    Du, LY
    Zhuang, HS
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2006, 384 (05) : 1186 - 1190
  • [19] Determination of urapidil by flow injection chemiluminescence
    Lang, HY
    Li, YR
    Zhang, WP
    Zhang, XJ
    Shen, YH
    CHEMICAL JOURNAL OF CHINESE UNIVERSITIES-CHINESE, 2003, 24 (04): : 618 - 620
  • [20] Flow injection chemiluminescence determination of tetracycline
    Townshend, A
    Ruengsitagoon, W
    Thongpoon, C
    Liawruangrath, S
    ANALYTICA CHIMICA ACTA, 2005, 541 (1-2) : 105 - 111