Phenylboronic acid immunoaffinity reactor coupled with flow injection chemiluminescence for determination of α-fetoprotein

被引:40
|
作者
Wu, Yafeng [1 ]
Zhuang, Yafeng [2 ]
Liu, Songqin [1 ]
He, Lin [3 ]
机构
[1] Southeast Univ, Sch Chem & Chem Engn, Jiangsu Prov Key Lab Biomat & Biodevices, Nanjing 210096, Peoples R China
[2] Changzhou Inst Technol, Dept Chem, Changzhou 213022, Peoples R China
[3] N Carolina State Univ, Dept Chem, Raleigh, NC 27695 USA
基金
中国国家自然科学基金;
关键词
3-Aminophenylboronic acid; alpha-Fetoprotein; Immunoaffinity reactor; Regeneration; Flow injection chemiluminescence;
D O I
10.1016/j.aca.2008.10.010
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A reusable and sensitive immunoassay based on phenylboronic acid immunoaffinity reactor in combination with flow injection chemiluminescence (CL) for determination of glycoprotein was described. The reactor was fabricated by immobilizing 3-aminophenylboronic acid (APBA) on glass microbeads with gamma-glycidoxypropyltrimethoxysilane (GPMS) as linkage. The a-fetoprotein (AFP) could be easily immobilized on the APBA coated beads through sugar-boronic interaction. After an off-line incubation, the mixture of the analyte AFP with horseradish peroxidase-labeled AFP antibody (HRP-anti-AFP) was injected into the reactor. This led the trapping of free HRP-anti-AFP by the surface coated AFP on glass beads. The trapped HRP-anti-AFP was detected by chemiluminescence due to its sensitizing effect on the reaction of luminol and hydrogen peroxide. Under optimal conditions, the chemiluminescent signal was proportional to AFP concentration in the range of 10-100 ng mL(-1). The whole assay process including regeneration of the reactor could be completed within 31 min. The proposed system showed acceptable detection and fabrication reproducibility, and the results obtained with the present method were in acceptable agreement with those from parallel single-analyte test of practical clinical sera. The described method enabled a low-cost, time saving and was potential to detect the serum AFP level in clinical diagnosis. (C) 2008 Elsevier B.V. All rights reserved.
引用
收藏
页码:186 / 193
页数:8
相关论文
共 50 条
  • [41] Sensitive Determination of Hemoglobin in Human Blood and Serum by Flow Injection Coupled with Chemiluminescence Detection
    Cao Jun-tao
    Wang Hui
    Chen Yong-hong
    Liu Yan-ming
    SPECTROSCOPY AND SPECTRAL ANALYSIS, 2014, 34 (01) : 241 - 245
  • [42] Selective determination of amino acids using flow injection analysis coupled with chemiluminescence detection
    Costin, JW
    Francis, PS
    Lewis, SW
    ANALYTICA CHIMICA ACTA, 2003, 480 (01) : 67 - 77
  • [43] Chemiluminescence determination of tiopronin and its metabolite 2-mercaptopropionic acid in human urine by HPLC coupled with flow injection
    Zhao, YN
    Baeyens, WRG
    Zhang, XR
    Calokerinos, AC
    Nakashima, K
    VanderWeken, G
    VanOverbeke, A
    CHROMATOGRAPHIA, 1997, 44 (1-2) : 31 - 36
  • [44] Chemiluminescence determination of tiopronin and its metabolite 2-mercaptopropionic acid in human urine by HPLC coupled with flow injection
    Yining Zhao
    W. R. G. Baeyens
    X. R. Zhang
    A. C. Calokerinos
    K. Nakashima
    G. Van Der Weken
    A. Van Overbeke
    Chromatographia, 1997, 44 : 31 - 36
  • [45] An automatic chemiluminescence method based on the multi-pumping flow system coupled with the fluidized reactor and direct-injection detector: Determination of uric acid in saliva samples
    Vakh, Christina
    Koronkiewicz, Stanislawa
    Kalinowski, Slawomir
    Moskvin, Leonid
    Bulatov, Andrey
    TALANTA, 2017, 167 : 725 - 732
  • [46] Determination of humic acid in natural waters by flow injection analysis with chemiluminescence detection
    Michalowski, J
    Halaburda, P
    Kojlo, A
    ANALYTICA CHIMICA ACTA, 2001, 438 (1-2) : 143 - 148
  • [47] Flow-injection chemiluminescence determination of chloroquine using peroxynitrous acid as oxidant
    Liang, YD
    Song, JF
    Yang, XF
    Guo, W
    TALANTA, 2004, 62 (04) : 757 - 763
  • [48] Determination of Enoxacin in Tablet by Flow Injection Chemiluminescence
    Ren Nailin
    Yang Chi
    ADVANCES IN CHEMISTRY RESEARCH II, PTS 1-3, 2012, 554-556 : 1880 - 1883
  • [49] Determination of oxytetracycline by flow injection with chemiluminescence detection
    Guo, LQ
    Xie, ZH
    Bian, XT
    Lin, XC
    Zhang, WL
    Liu, XH
    Chen, GN
    LUMINESCENCE, 2005, 20 (03) : 129 - 134
  • [50] Determination of Folic Acid by Solid-Phase Extraction and Flow Injection Chemiluminescence
    Zhao, Shi-Hao
    Zhang, Ping-Ping
    Zhao, Shi-Bin
    ASIAN JOURNAL OF CHEMISTRY, 2010, 22 (10) : 7557 - 7562