Distal Femoral Fixation: A Biomechanical Comparison of Trigen Retrograde Intramedullary (IM) Nail, Dynamic Condylar Screw (DCS), and Locking Compression Plate (LCP) Condylar Plate

被引:84
|
作者
Heiney, Jake P. [1 ]
Barnett, Michael D. [4 ]
Vrabec, Gregory A. [2 ]
Schoenfeld, Andrew J. [2 ]
Baji, Avinash [3 ]
Njus, Glen O. [3 ]
机构
[1] Promed Hlth Syst, Dept Orthopaed Surg, Toledo, OH USA
[2] Akron Gen Med Ctr, Dept Orthopaed, Akron, OH USA
[3] Univ Akron, Dept Biomed Engn, Akron, OH 44325 USA
[4] Wright State Univ, Sch Med, Dept Orthopaed Surg, Orthopaed Surg Resideucy Program,Miami Valley Hos, Dayton, OH USA
关键词
Locking condylar plate; Distal femoral fracture; Biomechanical; Retrograde femoral nail; Dynamic condylar screw; INVASIVE STABILIZATION SYSTEM; FEMUR FRACTURE FIXATION; SUPRACONDYLAR FRACTURES; INTERNAL-FIXATION; ELDERLY-PATIENTS; BUTTRESS PLATE; SIDE PLATE; LISS;
D O I
10.1097/TA.0b013e31815edeb8
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Background. The purpose of this study was to establish if there are biomechanical differences between implants in stiffness of construct, microdisplacement, and fatigue failure in a supracondylar femoral fracture model. Methods: A retrograde intramedullary (IM) nail, dynamic condylar screw (DCS), and locked condylar plate (LCP) were tested using 33-cm long synthetic femurs. A standardized supracondylar medial segmental defect was created in the distal femur bone models. A gap away from the distal joint axis and parallel to the knee axis was created for axial testing of the specimens (Arbeitsgemeinschaft fur Osteosynthesefragen [AO] type 33-A) and a T-fracture (33-C) was created for the fatigue testing of the specimens. Peak displacements were measured, and analysis was done to determine construct stiffness and gap micromotion in axial loading. Cyclic loading was performed for fatigue testing. Results: It was observed that there were statistically significant differences in micromotion across the fracture gap and overall stiffness of various implant constructs. The stiffness of the IM nail, DCS, and LCP were 1,106, 750, and 625 N/mm, respectively. The average total micromotion across the fracture gap for the IM nail, DCS, and LCP were 1.96, 10.55, and 17.74 mm, respectively. In fatigue testing, the IM nail distal screws failed at 9,000 cycles, the DCS did not fail (80,000 cycles completed), and the LCP failed at 19,000 and 23,500 cycles.. Conclusion: When considering micromotion and construct stiffness, the IM nail had statistically significant higher stiffness and significantly lower micromotion across the fracture gap with axial compression. Hence, the IM nail tested had the greatest stability for type 33-A fractures. However, the nail demonstrated the least amount of resistance to fatigue failure with type 33-C fractures, whereas the DCS did not fail with testing in any pattern.
引用
收藏
页码:443 / 449
页数:7
相关论文
共 50 条
  • [21] A PROSPECTIVE STUDY ON THE OUTCOMES FOLLOWING LCP CONDYLAR PLATE FIXATION IN AO TYPE C DISTAL FEMORAL FRACTURES
    Singhal, Vikas
    Gohiya, Ashish
    JOURNAL OF EVOLUTION OF MEDICAL AND DENTAL SCIENCES-JEMDS, 2015, 4 (93): : 15857 - 15862
  • [22] Short Term Investigation of the Functional Result in Distal Femoral Fractures Treated with Locking Compression Condylar Plate
    Ahmed, Nizam
    Javed, Muhammad Imran
    Keerio, Niaz Hussain
    Joyo, Muhammad Rafique
    Khanzada, Aftab Alam
    Shah, Ghazanfar Ali
    Noor, Syed Shahid
    JOURNAL OF RESEARCH IN MEDICAL AND DENTAL SCIENCE, 2021, 9 (11): : 5 - 8
  • [23] EXPERIMENTAL AND PROBABILISTIC FINITE ELEMENT ANALYSIS OF DISTAL FEMORAL FRACTURES: A COMPARISON OF LOCKING PLATE VERSUS INTRAMEDULLARY NAIL FIXATION
    Sales, Christina
    Mercer, Deana
    DeCoster, Thomas A.
    Taha, Mahmoud M. Reda
    PROCEEDINGS OF THE ASME SUMMER BIOENGINEERING CONFERENCE, 2010, 2010, : 731 - 732
  • [24] Impact of cement-augmented condylar screws in locking plate osteosynthesis for distal femoral fractures - A biomechanical analysis
    Bliemel, Christopher
    Oberkircher, Ludwig
    Bockmann, Benjamin
    Petzold, Eric
    Aigner, Rene
    Heyse, Thomas Jan
    Ruchholtz, Steffen
    Buecking, Benjamin
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2016, 47 (12): : 2688 - 2693
  • [25] Comparison of compression plate and flexible intramedullary nail fixation in pediatric femoral shaft fractures
    Caglar, Omur
    Aksoy, Mehmet C.
    Yazici, Muharrem
    Surat, Adil
    JOURNAL OF PEDIATRIC ORTHOPAEDICS-PART B, 2006, 15 (03): : 210 - 214
  • [26] Outcomes of distal femoral fractures treated with dynamic condylar screw (DCS) plate system: a single centre experience spanning 15 years
    Lemsanni, Meryem
    Najeb, Youssef
    PAN AFRICAN MEDICAL JOURNAL, 2021, 38
  • [27] Biomechanical analysis of distal femur fracture fixation: Fixed-angle screw-plate construct versus condylar blade plate
    Higgins, Thomas F.
    Pittman, Gavin
    Hines, Jerod
    Bachus, Kent N.
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2007, 21 (01) : 43 - 46
  • [28] Comparison of Less Invasive Stabilization System Plate and Retrograde Intramedullary Nail in the Fixation of Femoral Supracondylar Fractures in the Elderly: A Biomechanical Study
    Du, Yu-ren
    Ma, Jian-xiong
    Wang, Shuo
    Sun, Lei
    Wang, Ying
    Lu, Bin
    Bai, Hao-hao
    Hu, Yong-cheng
    Ma, Xin-long
    ORTHOPAEDIC SURGERY, 2019, 11 (02) : 311 - 317
  • [29] Biomechanical Comparison of Locking Compression Plate and Limited Contact Dynamic Compression Plate Combined with an Intramedullary Rod in a Canine Femoral Fracture-Gap Model
    Matres-Lorenzo, Luis
    Diop, Amadou
    Maurel, Nathalie
    Boucton, Marie-Charlotte
    Bernard, Fabrice
    Bernarde, Antoine
    VETERINARY SURGERY, 2016, 45 (03) : 319 - 326
  • [30] Supracondylar femoral fractures in elderly patients treated with the dynamic condylar screw and the retrograde intramedullary nail: a comparative study of the two methods
    A. Christodoulou
    I. Terzidis
    A. Ploumis
    S. Metsovitis
    A. Koukoulidis
    C. Toptsis
    Archives of Orthopaedic and Trauma Surgery, 2005, 125 : 73 - 79