Distal Femoral Fixation: A Biomechanical Comparison of Trigen Retrograde Intramedullary (IM) Nail, Dynamic Condylar Screw (DCS), and Locking Compression Plate (LCP) Condylar Plate

被引:84
|
作者
Heiney, Jake P. [1 ]
Barnett, Michael D. [4 ]
Vrabec, Gregory A. [2 ]
Schoenfeld, Andrew J. [2 ]
Baji, Avinash [3 ]
Njus, Glen O. [3 ]
机构
[1] Promed Hlth Syst, Dept Orthopaed Surg, Toledo, OH USA
[2] Akron Gen Med Ctr, Dept Orthopaed, Akron, OH USA
[3] Univ Akron, Dept Biomed Engn, Akron, OH 44325 USA
[4] Wright State Univ, Sch Med, Dept Orthopaed Surg, Orthopaed Surg Resideucy Program,Miami Valley Hos, Dayton, OH USA
关键词
Locking condylar plate; Distal femoral fracture; Biomechanical; Retrograde femoral nail; Dynamic condylar screw; INVASIVE STABILIZATION SYSTEM; FEMUR FRACTURE FIXATION; SUPRACONDYLAR FRACTURES; INTERNAL-FIXATION; ELDERLY-PATIENTS; BUTTRESS PLATE; SIDE PLATE; LISS;
D O I
10.1097/TA.0b013e31815edeb8
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Background. The purpose of this study was to establish if there are biomechanical differences between implants in stiffness of construct, microdisplacement, and fatigue failure in a supracondylar femoral fracture model. Methods: A retrograde intramedullary (IM) nail, dynamic condylar screw (DCS), and locked condylar plate (LCP) were tested using 33-cm long synthetic femurs. A standardized supracondylar medial segmental defect was created in the distal femur bone models. A gap away from the distal joint axis and parallel to the knee axis was created for axial testing of the specimens (Arbeitsgemeinschaft fur Osteosynthesefragen [AO] type 33-A) and a T-fracture (33-C) was created for the fatigue testing of the specimens. Peak displacements were measured, and analysis was done to determine construct stiffness and gap micromotion in axial loading. Cyclic loading was performed for fatigue testing. Results: It was observed that there were statistically significant differences in micromotion across the fracture gap and overall stiffness of various implant constructs. The stiffness of the IM nail, DCS, and LCP were 1,106, 750, and 625 N/mm, respectively. The average total micromotion across the fracture gap for the IM nail, DCS, and LCP were 1.96, 10.55, and 17.74 mm, respectively. In fatigue testing, the IM nail distal screws failed at 9,000 cycles, the DCS did not fail (80,000 cycles completed), and the LCP failed at 19,000 and 23,500 cycles.. Conclusion: When considering micromotion and construct stiffness, the IM nail had statistically significant higher stiffness and significantly lower micromotion across the fracture gap with axial compression. Hence, the IM nail tested had the greatest stability for type 33-A fractures. However, the nail demonstrated the least amount of resistance to fatigue failure with type 33-C fractures, whereas the DCS did not fail with testing in any pattern.
引用
收藏
页码:443 / 449
页数:7
相关论文
共 50 条
  • [31] Supracondylar femoral fractures in elderly patients treated with the dynamic condylar screw and the retrograde intramedullary nail: a comparative study of the two methods
    Christodoulou, A
    Terzidis, I
    Ploumis, A
    Metsovitis, S
    Koukoulidis, A
    Toptsis, C
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2005, 125 (02) : 73 - 79
  • [32] The Fibular Intramedullary Nail Versus Locking Plate and Lag Screw Fixation in the Management of Unstable Elderly Ankle Fractures: A Cadaveric Biomechanical Comparison
    Carter, Thomas H.
    Wallace, Robert
    Mackenzie, Samuel A.
    Oliver, William M.
    Duckworth, Andrew D.
    White, Timothy O.
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2020, 34 (11) : E401 - E406
  • [33] The Comparison of Dynamic Condylar Screw Plate to Proximal Femoral Nail in Reverse Oblique and Transverse Intertrochanteric Fractures: A Retrospective Study on 61 Patients
    Sensoez, Ersin
    Ergun, Selim
    Kayaalp, Mahmut Enes
    Eceviz, Engin
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2023, 15 (03)
  • [34] A biomechanical comparison of 3.5 locking compression plate fixation to 3.5 limited contact dynamic compression plate fixation in a canine cadaveric distal humeral metaphyseal gap model
    Filipowicz, D.
    Lanz, O.
    McLaughlin, R.
    Elder, S.
    Werre, S.
    VETERINARY AND COMPARATIVE ORTHOPAEDICS AND TRAUMATOLOGY, 2009, 22 (04) : 270 - 277
  • [35] Experimental and probabilistic analysis of distal femoral periprosthetic fracture: a comparison of locking plate and intramedullary nail fixation. Part A: experimental investigation
    Salas, Christina
    Mercer, Deana
    DeCoster, Thomas A.
    Taha, Mahmoud M. Reda
    COMPUTER METHODS IN BIOMECHANICS AND BIOMEDICAL ENGINEERING, 2011, 14 (02) : 157 - 164
  • [36] Comparison of the effect of interlocking intramedullary nail and internal fixation with locking compression plate in the treatment of tibial fracture
    Yang, Huifeng
    Qiao, Xiaohong
    Duan, Hubin
    Hao, Chunyan
    Zhang, Zhimin
    Xue, Jun
    Xue, Xiaofeng
    FASEB JOURNAL, 2021, 35
  • [37] Comparison of cutout resistance of dynamic condylar screw and proximal femoral nail in reverse oblique trochanteric fractures: A biomechanical study
    Cheema, Gursimrat Singh
    Rastogi, Amit
    Singh, Vakil
    Goel, Satish Chandra
    Mishra, Diwakar
    Arora, Sumit
    INDIAN JOURNAL OF ORTHOPAEDICS, 2012, 46 (03) : 259 - 265
  • [38] Comparison of cutout resistance of dynamic condylar screw and proximal femoral nail in reverse oblique trochanteric fractures: A biomechanical study
    Gursimrat Singh Cheema
    Amit Rastogi
    Vakil Singh
    Satish Chandra Goel
    Diwakar Mishra
    Sumit Arora
    Indian Journal of Orthopaedics, 2012, 46 : 259 - 265
  • [39] Locking retrograde nail, non-locking retrograde nail and plate fixation in the treatment of distal third femoral shaft fractures: radiographic, bone densitometry and clinical outcomes
    Meccariello, Luigi
    Bisaccia, Michele
    Ronga, Mario
    Falzarano, Gabriele
    Caraffa, Auro
    Rinonapoli, Giuseppe
    Grubor, Predrag
    Pace, Valerio
    Rollo, Giuseppe
    JOURNAL OF ORTHOPAEDICS AND TRAUMATOLOGY, 2021, 22 (01)
  • [40] Locking retrograde nail, non-locking retrograde nail and plate fixation in the treatment of distal third femoral shaft fractures: radiographic, bone densitometry and clinical outcomes
    Luigi Meccariello
    Michele Bisaccia
    Mario Ronga
    Gabriele Falzarano
    Auro Caraffa
    Giuseppe Rinonapoli
    Predrag Grubor
    Valerio Pace
    Giuseppe Rollo
    Journal of Orthopaedics and Traumatology, 2021, 22