Outcomes of distal femoral fractures treated with dynamic condylar screw (DCS) plate system: a single centre experience spanning 15 years

被引:2
|
作者
Lemsanni, Meryem [1 ]
Najeb, Youssef [1 ]
机构
[1] Mohammed VI Univ Hosp Ctr, Ibn Tofail Hosp, Dept Orthopaed & Trauma Surg, Abdelouahab Derraq St, Marrakech 40000, Morocco
关键词
Distal femur fracture; dynamic condylar screw; range of motion; Lysholm; FEMUR FRACTURES; LOCKING PLATES; EPIDEMIOLOGY; FIXATION; FAILURE;
D O I
10.11604/pamj.2021.38.363.27524
中图分类号
R1 [预防医学、卫生学];
学科分类号
1004 ; 120402 ;
摘要
Introduction: the dynamic condylar screw (DCS) plate is an angular stable fixation (95 degrees) system for distal femur fractures that allows for the ability to apply compression across the femoral condyles. The aim of this study was to evaluate our experience treating distal femur fractures with this device and give the long-term outcome. Methods: a retrospective study was undertaken in our institution during the period from January 2002 to December 2016. A total number of 240 patients with distal femur fractures were managed using DCS plate system and included in the study. The mean follow-up period was 33 months (26 62 months). Clinico-radiological progression of fracture union as well as the functional outcome was studied. Results: most of the fractures were closed injuries in young male patients resulting from traffic accidents. The average time to union was 12.6 weeks (range 11 23). Eight patients (3.3%) suffered superficial infection. Five patients (2.1%) developed deep venous thrombosis. Delayed union was observed in nine cases (3.7%) and non union in six cases (2.5%). At final follow-up, the mean range of motion (ROM) of knee was 115.7 degrees (100 degrees-148 degrees). The mean Knee Society Score (KSS) was 84.5 (59 94) and the mean Lysholm score was 88.6 (range, 61 96), translating to good clinical results. Conclusion: our study conclusively establishes that excellent functional outcome can be achieved with DCS plate inserted with skilled surgical technique in distal femur fractures including the ones that are communited or occurring in osteoporotic bone with a negligible complication rates.
引用
收藏
页数:11
相关论文
共 50 条
  • [1] Subtrochanteric Femoral Fractures Treated by Fixation with Dynamic Condylar Screw System
    Laghari, Muhammad Ayoub
    Makhdoom, Asadullah
    Pahore, Muhammad Khan
    Memon, Abbas
    Memon, Faheem Ahmed
    JOURNAL OF THE LIAQUAT UNIVERSITY OF MEDICAL AND HEALTH SCIENCES, 2011, 10 (03): : 134 - 137
  • [2] Dynamic Condylar Screw (DCS) versus Condylar Blade Plate (CBP) in Complex Supracondylar Femoral Fractures - A Biomechanical Study
    Sirbu, P. D.
    Carata, E.
    Petreus, T.
    Munteanu, F.
    Popescu, C.
    Asaftei, R.
    Botez, P.
    INTERNATIONAL CONFERENCE ON ADVANCEMENTS OF MEDICINE AND HEALTH CARE THROUGH TECHNOLOGY, 2009, 26 : 409 - +
  • [3] FRACTURES OF THE DISTAL FEMUR TREATED WITH THE AO DYNAMIC CONDYLAR SCREW
    SHEWRING, DJ
    MEGGITT, BF
    JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1992, 74 (01): : 122 - 125
  • [4] Five year results after dia/supracondylar femoral fractures treated with dynamic condylar screw (DCS)
    Ketterl, R
    Kostler, W
    Wittwer, W
    Stubinger, B
    ZENTRALBLATT FUR CHIRURGIE, 1997, 122 (11): : 1033 - 1039
  • [5] The mechanics of internal fixation of fractures of the distal femur: a comparison of the condylar screw (DCS) with the condylar plate (CP)
    Harder, Y
    Martinet, O
    Barraud, GE
    Cordey, J
    Regazzoni, P
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 1999, 30 : S31 - S39
  • [6] Is the Dynamic Condylar Screw System Effective in Fractures of Distal Femur?
    Shanmugasundaraml, Kumaravel
    Manoharan, M.
    RESEARCH JOURNAL OF PHARMACEUTICAL BIOLOGICAL AND CHEMICAL SCIENCES, 2015, 6 (02): : 1247 - 1254
  • [7] 1ST EXPERIENCES WITH THE DYNAMIC CONDYLAR SCREW (DCS) IN DISTAL FEMUR FRACTURES
    REGAZZONI, P
    LEUTENEGGER, A
    RUEDI, T
    STAEHELIN, F
    HELVETICA CHIRURGICA ACTA, 1986, 53 (1-2) : 61 - 64
  • [8] Distal Femoral Fixation: A Biomechanical Comparison of Trigen Retrograde Intramedullary (IM) Nail, Dynamic Condylar Screw (DCS), and Locking Compression Plate (LCP) Condylar Plate
    Heiney, Jake P.
    Barnett, Michael D.
    Vrabec, Gregory A.
    Schoenfeld, Andrew J.
    Baji, Avinash
    Njus, Glen O.
    JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 2009, 66 (02): : 443 - 449
  • [9] Outcomes of Dynamic Condylar Screw for the Treatment of Supracondylar Fractures of Distal Femur
    Bakhsh, Karim
    Shah, Syed Wasif Ali
    Ahmed, Nisar
    PAKISTAN JOURNAL OF MEDICAL & HEALTH SCIENCES, 2019, 13 (03): : 757 - 759
  • [10] Treatment of distal femur fractures with VA-LCP condylar plate: A single trauma centre experience
    Campana, V
    Ciolli, G.
    Cazzato, G.
    De Sanctis, E. Giovannetti
    Vitiello, C.
    Leone, A.
    Liuzza, F.
    Maccauro, G.
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2020, 51 : S39 - S44