Outcomes of distal femoral fractures treated with dynamic condylar screw (DCS) plate system: a single centre experience spanning 15 years

被引:2
|
作者
Lemsanni, Meryem [1 ]
Najeb, Youssef [1 ]
机构
[1] Mohammed VI Univ Hosp Ctr, Ibn Tofail Hosp, Dept Orthopaed & Trauma Surg, Abdelouahab Derraq St, Marrakech 40000, Morocco
关键词
Distal femur fracture; dynamic condylar screw; range of motion; Lysholm; FEMUR FRACTURES; LOCKING PLATES; EPIDEMIOLOGY; FIXATION; FAILURE;
D O I
10.11604/pamj.2021.38.363.27524
中图分类号
R1 [预防医学、卫生学];
学科分类号
1004 ; 120402 ;
摘要
Introduction: the dynamic condylar screw (DCS) plate is an angular stable fixation (95 degrees) system for distal femur fractures that allows for the ability to apply compression across the femoral condyles. The aim of this study was to evaluate our experience treating distal femur fractures with this device and give the long-term outcome. Methods: a retrospective study was undertaken in our institution during the period from January 2002 to December 2016. A total number of 240 patients with distal femur fractures were managed using DCS plate system and included in the study. The mean follow-up period was 33 months (26 62 months). Clinico-radiological progression of fracture union as well as the functional outcome was studied. Results: most of the fractures were closed injuries in young male patients resulting from traffic accidents. The average time to union was 12.6 weeks (range 11 23). Eight patients (3.3%) suffered superficial infection. Five patients (2.1%) developed deep venous thrombosis. Delayed union was observed in nine cases (3.7%) and non union in six cases (2.5%). At final follow-up, the mean range of motion (ROM) of knee was 115.7 degrees (100 degrees-148 degrees). The mean Knee Society Score (KSS) was 84.5 (59 94) and the mean Lysholm score was 88.6 (range, 61 96), translating to good clinical results. Conclusion: our study conclusively establishes that excellent functional outcome can be achieved with DCS plate inserted with skilled surgical technique in distal femur fractures including the ones that are communited or occurring in osteoporotic bone with a negligible complication rates.
引用
收藏
页数:11
相关论文
共 50 条
  • [31] Interprosthetic femoral fractures managed with modern distal femoral locking plates: 10 years' experience at a UK major trauma centre
    Mittal, Aaina
    Poole, William
    Crone, David
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2021, 52 (07): : 1918 - 1924
  • [32] Outcomes of distal femur fractures treated with the Synthes 4.5mm VA-LCP Curved Condylar Plate
    Dang, Khang H.
    Armstrong, Connor A.
    Karia, Ravi A.
    Zelle, Boris A.
    INTERNATIONAL ORTHOPAEDICS, 2019, 43 (07) : 1709 - 1714
  • [33] Outcomes of distal humerus fractures in patients above 65 years of age treated by plate fixation
    Clavert, P.
    Ducrot, G.
    Sirveaux, F.
    Fabre, T.
    Mansat, P.
    ORTHOPAEDICS & TRAUMATOLOGY-SURGERY & RESEARCH, 2013, 99 (07) : 771 - 777
  • [34] Supracondylar femoral fractures in elderly patients treated with the dynamic condylar screw and the retrograde intramedullary nail: a comparative study of the two methods
    A. Christodoulou
    I. Terzidis
    A. Ploumis
    S. Metsovitis
    A. Koukoulidis
    C. Toptsis
    Archives of Orthopaedic and Trauma Surgery, 2005, 125 : 73 - 79
  • [35] Supracondylar femoral fractures in elderly patients treated with the dynamic condylar screw and the retrograde intramedullary nail: a comparative study of the two methods
    Christodoulou, A
    Terzidis, I
    Ploumis, A
    Metsovitis, S
    Koukoulidis, A
    Toptsis, C
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2005, 125 (02) : 73 - 79
  • [36] The Comparison of Dynamic Condylar Screw Plate to Proximal Femoral Nail in Reverse Oblique and Transverse Intertrochanteric Fractures: A Retrospective Study on 61 Patients
    Sensoez, Ersin
    Ergun, Selim
    Kayaalp, Mahmut Enes
    Eceviz, Engin
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2023, 15 (03)
  • [37] Technik der biologischen Osteosynthese von subtrochantären Frakturen mit der dynamischen Kondylenschraube (DCS)Technique of Biologic Fixation of Subtrochanteric Femoral Fractures with Dynamic Condylar Screw (DCS)
    Shrinand V. Vaidya
    Devesh Dholakia
    Anirban Chatterjee
    Murali Poduval
    Operative Orthopädie und Traumatologie, 2002, 14 (4) : 335 - 343
  • [38] Are Locking Constructs in Distal Femoral Fractures Always Best? A Prospective Multicenter Randomized Controlled Trial Comparing the Less Invasive Stabilization System With the Minimally Invasive Dynamic Condylar Screw System
    Leighton, R. K.
    Schemitsch, E. H.
    Stephen, D. J. G.
    McCormack, R.
    Sanders, D.
    O'Brien, P.
    Buckley, R.
    Trask, K.
    Mckee, M. D.
    Schemitsch, E. H.
    Kreder, H. J.
    McCormack, R.
    Buckley, R.
    Robinson, J. de Dios
    Coles, C.
    Stephen, D. J. G.
    Buckley, R.
    Oxner, W.
    Amirault, J. D.
    Glazebrook, M.
    Waddell, J. P.
    Whelan, D.
    Hall, J. A.
    Wild, L. M.
    Vicente, M.
    Axelrod, T. A.
    Jenkinson, R.
    Stone, T. B.
    Panagiotopoulos, K.
    Piper, M.
    Zomar, M.
    MacLeod, M.
    Tieszer, C.
    Guy, P.
    Blachut, P.
    Broekhuyse, H.
    Johal, R.
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2016, 30 (01) : E1 - E6
  • [39] Comparison between Proximal Femoral Nail Antirotation (PFNA) and Dynamic Condylar Screw (DCS) in the Management of Unstable Proximal Femur Fractures in Term of Mean Union Time
    Akhtar, Muhammad Saleem
    Gillani, Haroon Ur Rehman
    Khan, Kashif Raza
    PAKISTAN JOURNAL OF MEDICAL & HEALTH SCIENCES, 2016, 10 (02): : 555 - 558
  • [40] Respiratory and Post-operative Outcomes in Early Onset Scoliosis Patients Treated with Rib Based Growing System: Single Centre Experience of 15 Years
    Ramirez, Norman
    Camacho, Lyanne
    Ibanez, Mary
    Ramirez, Nicole
    Torres, Yashira
    Montanez, Jose
    Olivella, Gerardo
    PEDIATRICS, 2021, 147 (03)