Outcomes of distal femoral fractures treated with dynamic condylar screw (DCS) plate system: a single centre experience spanning 15 years

被引:2
|
作者
Lemsanni, Meryem [1 ]
Najeb, Youssef [1 ]
机构
[1] Mohammed VI Univ Hosp Ctr, Ibn Tofail Hosp, Dept Orthopaed & Trauma Surg, Abdelouahab Derraq St, Marrakech 40000, Morocco
关键词
Distal femur fracture; dynamic condylar screw; range of motion; Lysholm; FEMUR FRACTURES; LOCKING PLATES; EPIDEMIOLOGY; FIXATION; FAILURE;
D O I
10.11604/pamj.2021.38.363.27524
中图分类号
R1 [预防医学、卫生学];
学科分类号
1004 ; 120402 ;
摘要
Introduction: the dynamic condylar screw (DCS) plate is an angular stable fixation (95 degrees) system for distal femur fractures that allows for the ability to apply compression across the femoral condyles. The aim of this study was to evaluate our experience treating distal femur fractures with this device and give the long-term outcome. Methods: a retrospective study was undertaken in our institution during the period from January 2002 to December 2016. A total number of 240 patients with distal femur fractures were managed using DCS plate system and included in the study. The mean follow-up period was 33 months (26 62 months). Clinico-radiological progression of fracture union as well as the functional outcome was studied. Results: most of the fractures were closed injuries in young male patients resulting from traffic accidents. The average time to union was 12.6 weeks (range 11 23). Eight patients (3.3%) suffered superficial infection. Five patients (2.1%) developed deep venous thrombosis. Delayed union was observed in nine cases (3.7%) and non union in six cases (2.5%). At final follow-up, the mean range of motion (ROM) of knee was 115.7 degrees (100 degrees-148 degrees). The mean Knee Society Score (KSS) was 84.5 (59 94) and the mean Lysholm score was 88.6 (range, 61 96), translating to good clinical results. Conclusion: our study conclusively establishes that excellent functional outcome can be achieved with DCS plate inserted with skilled surgical technique in distal femur fractures including the ones that are communited or occurring in osteoporotic bone with a negligible complication rates.
引用
收藏
页数:11
相关论文
共 50 条
  • [21] Outcomes of distal radial endoprostheses for tumour reconstruction: a single centre experience over 15 years
    Mahoney, Rachel
    Khan, Zeeshan
    Abudu, Adesegun
    Kurisunkal, Vineet
    Evans, Scott
    Jeys, Lee M.
    JOURNAL OF HAND SURGERY-EUROPEAN VOLUME, 2022, 47 (11) : 1147 - 1154
  • [22] Trochanteric femoral nonunion in patients aged over 60 years treated with dynamic condylar screw
    Lotzien, Sebastian
    Rosteius, Thomas
    Rausch, Valentin
    Schildhauer, Thomas Armin
    Gessmann, Jan
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2020, 51 (02): : 389 - 394
  • [23] A comparative study of Proximal Femoral Nail (PFN) versus Dynamic Condylar Screw (DCS) in management of unstable trochanteric fractures
    Jamil, Md Faraz
    Mohd, Julfiqar
    Abbas, Mazhar
    Siddiqui, Yasir Salam
    Khan, Mohammad Jesan
    INTERNATIONAL JOURNAL OF BURNS AND TRAUMA, 2022, 12 (03): : 83 - 92
  • [24] A PROSPECTIVE STUDY ON THE OUTCOMES FOLLOWING LCP CONDYLAR PLATE FIXATION IN AO TYPE C DISTAL FEMORAL FRACTURES
    Singhal, Vikas
    Gohiya, Ashish
    JOURNAL OF EVOLUTION OF MEDICAL AND DENTAL SCIENCES-JEMDS, 2015, 4 (93): : 15857 - 15862
  • [25] Treatment of Distal Femoral Fracture by Minimally Invasive Percutaneous Plate Osteosynthesis: Comparison Between the Dynamic Condylar Screw and the Less Invasive Stabilization System
    Kao, Feng C.
    Tu, Yuan K.
    Su, Juin Y.
    Hsu, Kuo Y.
    Wu, Chin H.
    Chou, Ming C.
    JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 2009, 67 (04): : 719 - 726
  • [26] Prevention of malunions in the rotation of complex fractures of the distal femur treated using the Dynamic Condylar Screw (DCS): An anatomical graphic analysis using computed tomography on cadaveric specimens
    Maier, A
    Cordey, J
    Regazzoni, P
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2000, 31 : 63 - 69
  • [27] Dynamic condylar screw or hip joint(spanning)external fixator for treatment of pathological fractures of femoral neck and trochanter secondary to benign lesions
    Dariabrooks Terrell
    Martin M.Malawer
    中华医学杂志(英文版), 2008, (02) : 178 - 180
  • [28] Dynamic condylar screw or hip joint (spanning) external fixator for treatment of pathological fractures of femoral neck and trochanter secondary to benign lesions
    Zhang Chun-lin
    Zeng Bing-fang
    Dong Yang
    Terrell, Daria Brooks
    Malawer, Martin M.
    CHINESE MEDICAL JOURNAL, 2008, 121 (02) : 178 - 180
  • [29] Outcomes of distal femur fractures treated with the Synthes 4.5 mm VA-LCP Curved Condylar Plate
    Khang H. Dang
    Connor A. Armstrong
    Ravi A. Karia
    Boris A. Zelle
    International Orthopaedics, 2019, 43 : 1709 - 1714
  • [30] Salvage procedures for trochanteric femoral fractures after internal fixation failure: Biomechanical comparison of a plate fixator and the dynamic condylar screw
    Konstantinidis, L.
    Papaioannou, C.
    Mehlhorn, A.
    Hirschmueller, A.
    Suedkamp, N. P.
    Helwig, P.
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2011, 225 (H7) : 710 - 717