Determination of silicon in biomass and products of pyrolysis process via high-resolution continuum source atomic absorption spectrometry

被引:12
|
作者
Nakadi, Flavio V. [1 ]
Prodanov, Caroline [1 ]
Boschetti, Wiliam [1 ]
Vale, Maria Goreti R. [1 ,2 ]
Welz, Bernhard [2 ,3 ]
de Andrade, Jailson B. [2 ]
机构
[1] Univ Fed Rio Grande do Sul, Inst Quim, Porto Alegre, RS, Brazil
[2] Univ Fed Bahia, Inst Nacl Ciencia & Tecnol, CNPq, INCT Energia & Ambiente, Salvador, BA, Brazil
[3] Univ Fed Santa Catarina, Dept Quim, Florianopolis, SC, Brazil
关键词
Biomass; Bio-oil; Silicon determination; High-resolution continuum source atomic absorption spectrometry; Mass balance; SEQUENTIAL MULTIELEMENT DETERMINATION; OPTICAL-EMISSION SPECTROMETRY; SOLID SAMPLE ANALYSIS; LANDFILL GAS; BIO-OILS; GF AAS; ELEMENTS; SI; IDENTIFICATION; COMBUSTION;
D O I
10.1016/j.talanta.2017.12.022
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Thermochemical processes can convert the biomass into fuels, such as bio-oil. The biomass submitted to pyrolysis process, such as fibers, are generally rich in silicon, an element that can lead to damages in an engine when there is high concentration in a fuel. High-resolution continuum source atomic absorption spectrometry (HR-CS AAS) is an interesting alternative for Si determination in the products and byproducts of the pyrolysis process because, besides the flame (F) and graphite furnace (GF) atomizers, it has enhanced the application of direct analysis of solid samples (SS) within GF. This study aimed the development of methods to determine Si in biomass samples, their products and byproducts using HR-CS AAS. A high-resolution continuum source atomic absorption spectrometer contrAA 700 equipped with F and GF atomizers was used throughout the study. HR-CS F AAS (lambda = 251.611 nm, 1 detection pixel, N2O/C2H2 flame) was used to evaluate Si content in biomass and ash, after a microwave-assisted acid digestion with HNO3 and HF. HR-CS GF AAS (T-pyr = 1400 degrees C, T-atom = 2650 degrees C) has evaluated Si in pyrolysis water and bio-oil at 251.611 nm, and in peach pit biomass and ash at 221.174 nm using SS, both wavelengths with 1 detection pixel. Rhodium (300 mu g) was applied as permanent modifier and 10 mu g Pd + 6 mu g Mg were pipetted onto the standards/samples at each analysis. Three different biomass samples were studied: palm tree fiber, coconut fiber and peach pit, and three certified reference materials (CRM) were used to verify the accuracy of the methods. The figures of merit were LOD 0.09-20 mg kg(-1), and LOQ 0.3-20 mg kg(-1), considering all the methods. There were no significant differences between the CRM certified values and the determined ones, using a Student t-test with a confidence interval of 95% (n = 5). Si concentration ranged from 0.11-0.92% m m(-1), 1.1-1.7 mg kg(-1), 3.3-13 mg kg(-1), and 0.41-1.4% m m(-1), in biomass, bio-oil, pyrolysis water and ash, respectively. Si remained mostly in the ash, leading to a mass fraction of up to 103%, even when the Si loss is not considered. Silicon concentration in bio-oil was below 1.7 mg kg(-1), which is suitable for its application as a fuel. The developed methods using HR-CS AAS are suitable for Si determination in biomass, bio-oil, pyrolysis water, and ash. The application of bio-oil as an alternative fuel would be possible evaluating its Si content due to its low levels. The mass balance for Si has proved to be an important tool in order to evaluate the correct disposal of pyrolysis process byproducts.
引用
收藏
页码:828 / 835
页数:8
相关论文
共 50 条
  • [21] High-resolution continuum source AAS: the better way to perform atomic absorption spectrometry
    Welz, B
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2005, 381 (01) : 69 - 71
  • [22] High-resolution continuum source AAS: the better way to perform atomic absorption spectrometry
    Bernard Welz
    Analytical and Bioanalytical Chemistry, 2005, 381 : 69 - 71
  • [23] A practical method for the determination of sulphur in coal samples by high-resolution continuum source flame atomic absorption spectrometry
    Baysal, A.
    Akman, S.
    TALANTA, 2011, 85 (05) : 2662 - 2665
  • [24] Determination of heavy metals in cigarettes using high-resolution continuum source graphite furnace atomic absorption spectrometry
    Ren, Ting
    Chen, Xi
    Ge, Yao
    Zhao, Lijiao
    Zhong, Rugang
    ANALYTICAL METHODS, 2017, 9 (27) : 4033 - 4043
  • [25] Feasibility of high-resolution continuum source molecular absorption spectrometry in flame and furnace for sulphur determination in petroleum products
    Kowalewska, Zofia
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2011, 66 (07) : 546 - 556
  • [26] Simultaneous determination of Cd and Fe in grain products using direct solid sampling and high-resolution continuum source electrothermal atomic absorption spectrometry
    dos Santos, Lisia M. G.
    Araujo, Rennan G. O.
    Welz, Bernhard
    Jacob, Silvana Do C.
    Vale, Maria Goreti R.
    Becker-Ross, Helmut
    TALANTA, 2009, 78 (02) : 577 - 583
  • [27] Determination of silicon in plant materials using direct solid sample analysis with high-resolution continuum source graphite furnace atomic absorption spectrometry
    Boschetti, Wiliam
    Dalagnol, Luiza M. G.
    Dullius, Mariana
    Zmozinski, Ariane V.
    Becker, Emilene M.
    Vale, Maria Goreti R.
    de Andrade, Jailson B.
    MICROCHEMICAL JOURNAL, 2016, 124 : 380 - 385
  • [28] Sequential and simultaneous determination of chlorine, iron, and silicon in beer samples by high-resolution continuum source graphite furnace molecular and atomic absorption spectrometry
    Pires, Lais N.
    Almeida, Jorge S.
    Dias, Fabio de S.
    Teixeira, Leonardo S. G.
    FOOD ANALYTICAL METHODS, 2020, 13 (09) : 1746 - 1754
  • [29] Sequential and simultaneous determination of chlorine, iron, and silicon in beer samples by high-resolution continuum source graphite furnace molecular and atomic absorption spectrometry
    Laís N. Pires
    Jorge S. Almeida
    Fabio de S. Dias
    Leonardo S. G. Teixeira
    Food Analytical Methods, 2020, 13 : 1746 - 1754
  • [30] Slurry sampling and high-resolution continuum source flame atomic absorption spectrometry using secondary lines for the determination of Ca and Mg in dairy products
    Brandao, Geovani C.
    Matos, Geraldo D.
    Ferreira, Sergio L. C.
    MICROCHEMICAL JOURNAL, 2011, 98 (02) : 231 - 233