Determination of silicon in biomass and products of pyrolysis process via high-resolution continuum source atomic absorption spectrometry

被引:12
|
作者
Nakadi, Flavio V. [1 ]
Prodanov, Caroline [1 ]
Boschetti, Wiliam [1 ]
Vale, Maria Goreti R. [1 ,2 ]
Welz, Bernhard [2 ,3 ]
de Andrade, Jailson B. [2 ]
机构
[1] Univ Fed Rio Grande do Sul, Inst Quim, Porto Alegre, RS, Brazil
[2] Univ Fed Bahia, Inst Nacl Ciencia & Tecnol, CNPq, INCT Energia & Ambiente, Salvador, BA, Brazil
[3] Univ Fed Santa Catarina, Dept Quim, Florianopolis, SC, Brazil
关键词
Biomass; Bio-oil; Silicon determination; High-resolution continuum source atomic absorption spectrometry; Mass balance; SEQUENTIAL MULTIELEMENT DETERMINATION; OPTICAL-EMISSION SPECTROMETRY; SOLID SAMPLE ANALYSIS; LANDFILL GAS; BIO-OILS; GF AAS; ELEMENTS; SI; IDENTIFICATION; COMBUSTION;
D O I
10.1016/j.talanta.2017.12.022
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Thermochemical processes can convert the biomass into fuels, such as bio-oil. The biomass submitted to pyrolysis process, such as fibers, are generally rich in silicon, an element that can lead to damages in an engine when there is high concentration in a fuel. High-resolution continuum source atomic absorption spectrometry (HR-CS AAS) is an interesting alternative for Si determination in the products and byproducts of the pyrolysis process because, besides the flame (F) and graphite furnace (GF) atomizers, it has enhanced the application of direct analysis of solid samples (SS) within GF. This study aimed the development of methods to determine Si in biomass samples, their products and byproducts using HR-CS AAS. A high-resolution continuum source atomic absorption spectrometer contrAA 700 equipped with F and GF atomizers was used throughout the study. HR-CS F AAS (lambda = 251.611 nm, 1 detection pixel, N2O/C2H2 flame) was used to evaluate Si content in biomass and ash, after a microwave-assisted acid digestion with HNO3 and HF. HR-CS GF AAS (T-pyr = 1400 degrees C, T-atom = 2650 degrees C) has evaluated Si in pyrolysis water and bio-oil at 251.611 nm, and in peach pit biomass and ash at 221.174 nm using SS, both wavelengths with 1 detection pixel. Rhodium (300 mu g) was applied as permanent modifier and 10 mu g Pd + 6 mu g Mg were pipetted onto the standards/samples at each analysis. Three different biomass samples were studied: palm tree fiber, coconut fiber and peach pit, and three certified reference materials (CRM) were used to verify the accuracy of the methods. The figures of merit were LOD 0.09-20 mg kg(-1), and LOQ 0.3-20 mg kg(-1), considering all the methods. There were no significant differences between the CRM certified values and the determined ones, using a Student t-test with a confidence interval of 95% (n = 5). Si concentration ranged from 0.11-0.92% m m(-1), 1.1-1.7 mg kg(-1), 3.3-13 mg kg(-1), and 0.41-1.4% m m(-1), in biomass, bio-oil, pyrolysis water and ash, respectively. Si remained mostly in the ash, leading to a mass fraction of up to 103%, even when the Si loss is not considered. Silicon concentration in bio-oil was below 1.7 mg kg(-1), which is suitable for its application as a fuel. The developed methods using HR-CS AAS are suitable for Si determination in biomass, bio-oil, pyrolysis water, and ash. The application of bio-oil as an alternative fuel would be possible evaluating its Si content due to its low levels. The mass balance for Si has proved to be an important tool in order to evaluate the correct disposal of pyrolysis process byproducts.
引用
收藏
页码:828 / 835
页数:8
相关论文
共 50 条
  • [31] Determination of Sulfur in Plant Using a High-Resolution Continuum Source Atomic Absorption Spectrometer
    Wang Yu
    Li Jia-xi
    SPECTROSCOPY AND SPECTRAL ANALYSIS, 2009, 29 (05) : 1418 - 1421
  • [32] The chemical generation of NO for the determination of nitrite by high-resolution continuum source molecular absorption spectrometry
    Brandao, Geovani C.
    Lima, Daniel C.
    Ferreira, Sergio L. C.
    TALANTA, 2012, 98 : 231 - 235
  • [33] High-resolution continuum source electrothermal absorption spectrometry of AlBr and CaBr for the determination of bromine
    Huang, Mao Dong
    Becker-Ross, Helmut
    Florek, Stefan
    Heitmann, Uwe
    Okruss, Michael
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2008, 63 (05) : 566 - 570
  • [34] Straightforward silicon determination in water-in-oil-in-water emulsions used for silicon supplementations in food by high-resolution continuum source flame atomic absorption spectrometry
    Gomez-Nieto, Beatriz
    Jesus Gismera, Ma
    Teresa Sevilla, Ma
    Cofrades, Susana
    Freire, Maria
    Procopio, Jesus R.
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2018, 148 : 44 - 50
  • [35] Direct determination of lead in bones using slurry sampling and high-resolution continuum source electrothermal atomic absorption spectrometry
    Husakova, Lenka
    Sidova, Tereza
    Ibrahimova, Lucie
    Svizelova, Monika
    Mikysek, Tomas
    ANALYTICAL METHODS, 2019, 11 (09) : 1254 - 1263
  • [36] Determination of sulfur by high-resolution continuum source atomic absorption spectrometry: Review of studies over the last 10 years
    Ozbek, Nil
    Baysal, Asli
    TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2017, 88 : 62 - 76
  • [37] Determination of cadmium in coal using solid sampling graphite furnace high-resolution continuum source atomic absorption spectrometry
    da Silva, AF
    Borges, DLG
    Lepri, FG
    Welz, B
    Curtius, AJ
    Heitmann, U
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2005, 382 (08) : 1835 - 1841
  • [38] Determination of cadmium in coal using solid sampling graphite furnace high-resolution continuum source atomic absorption spectrometry
    Alessandra Furtado da Silva
    Daniel L. G. Borges
    Fábio Grandis Lepri
    Bernhard Welz
    Adilson J. Curtius
    Uwe Heitmann
    Analytical and Bioanalytical Chemistry, 2005, 382 : 1835 - 1841
  • [39] High-Resolution Continuum Source Atomic Absorption Spectrometry with Microwave-Assisted Extraction for the Determination of Metals in Vegetable Sprouts
    Blicharska, E.
    Flieger, J.
    Oszust, K.
    Frac, M.
    Swieboda, R.
    Kocjan, R.
    ANALYTICAL LETTERS, 2015, 48 (14) : 2272 - 2287
  • [40] High-resolution continuum source graphite furnace atomic absorption spectrometry for the monitoring of Au nanoparticles
    Resano, Martin
    Garcia-Ruiz, Esperanza
    Garde, Raul
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2016, 31 (11) : 2233 - 2241