Determination of silicon in biomass and products of pyrolysis process via high-resolution continuum source atomic absorption spectrometry

被引:12
|
作者
Nakadi, Flavio V. [1 ]
Prodanov, Caroline [1 ]
Boschetti, Wiliam [1 ]
Vale, Maria Goreti R. [1 ,2 ]
Welz, Bernhard [2 ,3 ]
de Andrade, Jailson B. [2 ]
机构
[1] Univ Fed Rio Grande do Sul, Inst Quim, Porto Alegre, RS, Brazil
[2] Univ Fed Bahia, Inst Nacl Ciencia & Tecnol, CNPq, INCT Energia & Ambiente, Salvador, BA, Brazil
[3] Univ Fed Santa Catarina, Dept Quim, Florianopolis, SC, Brazil
关键词
Biomass; Bio-oil; Silicon determination; High-resolution continuum source atomic absorption spectrometry; Mass balance; SEQUENTIAL MULTIELEMENT DETERMINATION; OPTICAL-EMISSION SPECTROMETRY; SOLID SAMPLE ANALYSIS; LANDFILL GAS; BIO-OILS; GF AAS; ELEMENTS; SI; IDENTIFICATION; COMBUSTION;
D O I
10.1016/j.talanta.2017.12.022
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Thermochemical processes can convert the biomass into fuels, such as bio-oil. The biomass submitted to pyrolysis process, such as fibers, are generally rich in silicon, an element that can lead to damages in an engine when there is high concentration in a fuel. High-resolution continuum source atomic absorption spectrometry (HR-CS AAS) is an interesting alternative for Si determination in the products and byproducts of the pyrolysis process because, besides the flame (F) and graphite furnace (GF) atomizers, it has enhanced the application of direct analysis of solid samples (SS) within GF. This study aimed the development of methods to determine Si in biomass samples, their products and byproducts using HR-CS AAS. A high-resolution continuum source atomic absorption spectrometer contrAA 700 equipped with F and GF atomizers was used throughout the study. HR-CS F AAS (lambda = 251.611 nm, 1 detection pixel, N2O/C2H2 flame) was used to evaluate Si content in biomass and ash, after a microwave-assisted acid digestion with HNO3 and HF. HR-CS GF AAS (T-pyr = 1400 degrees C, T-atom = 2650 degrees C) has evaluated Si in pyrolysis water and bio-oil at 251.611 nm, and in peach pit biomass and ash at 221.174 nm using SS, both wavelengths with 1 detection pixel. Rhodium (300 mu g) was applied as permanent modifier and 10 mu g Pd + 6 mu g Mg were pipetted onto the standards/samples at each analysis. Three different biomass samples were studied: palm tree fiber, coconut fiber and peach pit, and three certified reference materials (CRM) were used to verify the accuracy of the methods. The figures of merit were LOD 0.09-20 mg kg(-1), and LOQ 0.3-20 mg kg(-1), considering all the methods. There were no significant differences between the CRM certified values and the determined ones, using a Student t-test with a confidence interval of 95% (n = 5). Si concentration ranged from 0.11-0.92% m m(-1), 1.1-1.7 mg kg(-1), 3.3-13 mg kg(-1), and 0.41-1.4% m m(-1), in biomass, bio-oil, pyrolysis water and ash, respectively. Si remained mostly in the ash, leading to a mass fraction of up to 103%, even when the Si loss is not considered. Silicon concentration in bio-oil was below 1.7 mg kg(-1), which is suitable for its application as a fuel. The developed methods using HR-CS AAS are suitable for Si determination in biomass, bio-oil, pyrolysis water, and ash. The application of bio-oil as an alternative fuel would be possible evaluating its Si content due to its low levels. The mass balance for Si has proved to be an important tool in order to evaluate the correct disposal of pyrolysis process byproducts.
引用
收藏
页码:828 / 835
页数:8
相关论文
共 50 条
  • [11] Feasibility of filter atomization in high-resolution continuum source atomic absorption spectrometry
    Heitmann, Uwe
    Becker-Ross, Helmut
    Katskov, Dmitri
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2006, 61 (03) : 351 - 360
  • [12] Quo vadis high-resolution continuum source atomic/molecular absorption spectrometry?
    Resano, M.
    Garcia-Ruiz, E.
    Aramendia, M.
    Belarra, M. A.
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2019, 34 (01) : 59 - 80
  • [13] High-resolution continuum source atomic absorption spectrometry: a review of current applications
    V. V. Eskina
    V. B. Baranovskaya
    Yu. A. Karpov
    D. G. Filatova
    Russian Chemical Bulletin, 2020, 69 : 1 - 16
  • [14] High-resolution continuum source atomic absorption spectrometry: a review of current applications
    Eskina, V. V.
    Baranovskaya, V. B.
    Karpov, Yu. A.
    Filatova, D. G.
    RUSSIAN CHEMICAL BULLETIN, 2020, 69 (01) : 1 - 16
  • [15] Simultaneous determination of rhodium and ruthenium by high-resolution continuum source graphite furnace atomic absorption spectrometry
    Zambrzycka-Szelewa, Elzbieta
    Lulewicz, Marta
    Godlewska-Zylkiewicz, Beata
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2017, 133 : 81 - 87
  • [16] Direct determination of P in biodiesel by high-resolution continuum source graphite furnace atomic absorption spectrometry
    de Campos, Reinaldo Calixto
    Correia, Carolina Lyrio T.
    Vieira, Flavia
    Saint'Pierre, Tatiana D.
    Oliveira, Ana Cristina
    Goncalves, Rodrigo
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2011, 66 (05) : 352 - 355
  • [17] Determination of Cu and Mn in Seawater by High-Resolution Continuum Source Graphite Furnace Atomic Absorption Spectrometry
    Burylin, Mikhail Yu
    Kopeyko, Elena S.
    Bauer, Viktoriya A.
    ANALYTICAL LETTERS, 2022, 55 (10) : 1663 - 1671
  • [19] Feasibility of high-resolution continuum source molecular absorption spectrometry for vanadium determination
    Kowalewska, Zofia
    Abad, Carlos
    Okruss, Michael
    Recknagel, Sebastian
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2023, 38 (02) : 472 - 483
  • [20] Determination of Silicon in Vegetable Oil and Biodiesel by High-Resolution Continuum Source Flame Atomic Absorption Spectrometry Using Sample Dilution with Xylene
    de Oliveira, Ligia C. C.
    Vieira, Mariana A.
    Ribeiro, Anderson S.
    Lisboa, Meibel T.
    Goncalves, Rodrigo A.
    de Campos, Reinaldo C.
    ENERGY & FUELS, 2012, 26 (11) : 7041 - 7044