A practical method for the determination of sulphur in coal samples by high-resolution continuum source flame atomic absorption spectrometry

被引:58
|
作者
Baysal, A. [1 ]
Akman, S. [1 ]
机构
[1] Istanbul Tech Univ, Fac Sci & Letters, Dept Chem, TR-34469 Istanbul, Turkey
关键词
High resolution continuum source atomic absorption spectrometry; Sulphur; Coal; Molecular absorption; PLASMA-MASS SPECTROMETRY; AIR-ACETYLENE FLAME; MOLECULAR ABSORPTION; FLOW-INJECTION; SPECTROPHOTOMETRIC DETERMINATION; SULFATE ION; DIOXIDE; SULFIDE; COLUMN;
D O I
10.1016/j.talanta.2011.08.038
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Sulphur in coal was determined using a high-resolution continuum source flame atomic absorption spectrophotometer (HR-CS-FAAS) with actylene/air flame. The C-S absorption band at 258.056 nm was found the most suitable analytical line with respect to sensitivity and spectral interferences. The instrumental parameters were optimized. The coal samples were dried and dissolved using microwave-assisted digestion technique. The validity of the method was tested using standard reference material and certified values were found in the limits of 95% confidence level. Since the concentrations of matrix elements of coal other than carbon are low enough not to cause any spectral interferences, the linear calibration method was applied in all quantifications without any problem. The calibration standards were prepared in sulphuric acid. The method was accurate, fast, simple and sensitive. The limit of detection CLOD, 33, N = 10) and the limit of quantification (LOQ 10 delta, N = 10) were found to be 0.01 and 0.03% (w/w), respectively. The sulphur concentrations of various kinds of the coal samples received around Turkey were determined. The sulphur contents of the coal samples were ranged from <= LOQ to 1.2%. (C) 2011 Elsevier By. All rights reserved.
引用
收藏
页码:2662 / 2665
页数:4
相关论文
共 50 条
  • [1] A new approach for the determination of sulphur in food samples by high-resolution continuum source flame atomic absorption spectrometer
    Ozbek, N.
    Baysal, A.
    FOOD CHEMISTRY, 2015, 168 : 460 - 463
  • [2] Feasibility of high-resolution continuum source molecular absorption spectrometry in flame and furnace for sulphur determination in petroleum products
    Kowalewska, Zofia
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2011, 66 (07) : 546 - 556
  • [3] Determination of Total Sulfur in Agricultural Samples by High-Resolution Continuum Source Flame Molecular Absorption Spectrometry
    Virgilio, Alex
    Raposo, Jorge L., Jr.
    Cardoso, Arnaldo A.
    Nobrega, Joaquim A.
    Gomes Neto, Jose A.
    JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 2011, 59 (06) : 2197 - 2201
  • [4] Extraction method based on emulsion breaking for the determination of Cu, Fe and Pb in Brazilian automotive gasoline samples by high-resolution continuum source flame atomic absorption spectrometry
    Leite, Clarice C.
    de Jesus, Alexandre
    Kolling, Leandro
    Ferrao, Marco F.
    Samios, Dimitrios
    Silva, Marcia M.
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2018, 142 : 62 - 67
  • [5] Determination of cadmium in coal using solid sampling graphite furnace high-resolution continuum source atomic absorption spectrometry
    da Silva, AF
    Borges, DLG
    Lepri, FG
    Welz, B
    Curtius, AJ
    Heitmann, U
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2005, 382 (08) : 1835 - 1841
  • [6] Determination of cadmium in coal using solid sampling graphite furnace high-resolution continuum source atomic absorption spectrometry
    Alessandra Furtado da Silva
    Daniel L. G. Borges
    Fábio Grandis Lepri
    Bernhard Welz
    Adilson J. Curtius
    Uwe Heitmann
    Analytical and Bioanalytical Chemistry, 2005, 382 : 1835 - 1841
  • [7] Three Advantages of High-Resolution Continuum Source Atomic Absorption Spectrometry
    Sun, Siqi
    SPECTROSCOPY, 2021, 36 (08) : 22 - 22
  • [8] High-Resolution Continuum Source Atomic and Molecular Absorption Spectrometry - A Review
    Welz, Bernhard
    Mores, Silvane
    Carasek, Eduardo
    Vale, Maria Goreti R.
    Okruss, Michael
    Becker-Ross, Helmut
    APPLIED SPECTROSCOPY REVIEWS, 2010, 45 (05) : 327 - 354
  • [9] Determination of Cr and Ni in Seawater by High-Resolution Continuum Source Electrothermal Atomic Absorption Spectrometry
    M. Yu. Burylin
    E. S. Kopeyko
    E. S. Kostyuchenko
    Journal of Analytical Chemistry, 2024, 79 : 310 - 317
  • [10] Determination of Gold by High-Resolution Continuum Source Atomic Absorption Spectrometry with Chemical Vapor Generation
    Krawczyk, Magdalena
    Matusiewicz, Henryk
    JOURNAL OF THE BRAZILIAN CHEMICAL SOCIETY, 2013, 24 (05) : 749 - 757