Evaluation of an OSEM-based PVC method for SPECT with clinical data

被引:0
|
作者
Erlandsson, Kjell [1 ]
Thomas, Benjamin [1 ]
Dickson, John [1 ]
Hutton, Brian F. [1 ]
机构
[1] UCL, Inst Nucl Med, London, England
关键词
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Partial volume correction (PVC) can compensate for cross-talk between different anatomical regions in images from a functional imaging system with poor spatial resolution, such as PET or SPECT, by utilizing data from a high-resolution structural imaging modality, such as CT or MRI. We have developed a new PVC method for SPECT, and here we present an evaluation of this method using clinical data from [I-123]-FP-CIT (DATscan) studies. PVC was performed based on MRI data, which were segmented and co-registered to the SPECT data. The correction was applied during OSEM reconstruction, taking into account the distance dependent resolution of the SPECT system. We compared our new method (OSEM-PVC) with OSEM reconstruction with resolution recovery (OSEM-RR). Qualitatively, OSEM-PVC resulted in images with visually improved structural definition and, quantitatively, it gave similar contrast as OSEM-RR but lower intra-region variability.
引用
收藏
页码:2687 / 2690
页数:4
相关论文
共 50 条
  • [21] A semiquantitative cortical circumferential normalization method for clinical evaluation of rCBF brain SPECT
    Liu, HG
    Mountz, JM
    Inampudi, C
    SanPedro, EC
    Deutsch, G
    CLINICAL NUCLEAR MEDICINE, 1997, 22 (09) : 596 - 604
  • [22] PERFORMANCE INDEX - A METHOD FOR QUANTITATIVE-EVALUATION OF FILTERS USED IN CLINICAL SPECT
    CONTINO, J
    TOUYA, JJ
    CORBUS, HF
    RAHIMIAN, J
    JOURNAL OF NUCLEAR MEDICINE, 1984, 25 (05) : P88 - P88
  • [23] PERFORMANCE INDEX - A METHOD FOR QUANTITATIVE-EVALUATION OF FILTERS USED IN CLINICAL SPECT
    RAHIMIAN, J
    CONTINO, J
    CORBUS, HF
    TOUYA, JJ
    MEDICAL PHYSICS, 1984, 11 (03) : 404 - 404
  • [24] Further improvement in the efficiency of model-based scatter estimation for use in OSEM SPECT reconstruction.
    Hutton, BF
    Lau, YH
    JOURNAL OF NUCLEAR MEDICINE, 1997, 38 (05) : 325 - 325
  • [25] Evaluation of a 3D-OSEM algorithm in the reconstruction of selected portions of the gated-SPECT cardiac cycle.
    Auth, Mallory
    Leonard, Scott
    Wu, Edwin
    Holly, Thomas
    McDonald, Nancy
    Spies, Stewart
    JOURNAL OF NUCLEAR MEDICINE, 2009, 50
  • [26] QUANTITATIVE SPECT BY ATTENUATION CORRECTION OF THE PROJECTION SET USING TRANSMISSION DATA - EVALUATION OF A METHOD
    ALMQUIST, H
    PALMER, J
    LJUNGBERG, M
    WOLLMER, P
    STRAND, SE
    JONSON, B
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 1990, 16 (8-10): : 587 - 594
  • [27] Clinical Evaluation of the Wide Beam Reconstruction Method for Ultra High Resolution Bone SPECT
    Coleman, R. E.
    Sandler, M. P.
    Patton, J. A.
    Machac, J.
    Kim, S.
    Kim, C. K.
    Shwartz, S. C.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2005, 32 : S255 - S255
  • [28] Semiquantitative analysis of striatal SPECT studies with BasGanV2 and manual ROI method: the FBP and the OSEM reconstruction algorithm
    Tranfaglia, C.
    Pagan, L.
    Galli, S.
    Lucchi, G.
    Zoboli, S.
    Guidarelli, G.
    Fagioli, G.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2011, 38 : S333 - S334
  • [29] A method of overlap correction for fully 3D OSEM reconstruction of PET data
    Ross, S
    Stearns, C
    Manjeshwar, R
    Iatrou, M
    2004 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-7, 2004, : 3497 - 3500
  • [30] Analysis of a SPECT OSEM reconstruction method with 3D beam modeling and optional attenuation correction: Phantom studies
    Vija, AH
    Hawman, EG
    Engdahl, JC
    2003 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORD, VOLS 1-5, 2004, : 2662 - 2666