Evaluation of an OSEM-based PVC method for SPECT with clinical data

被引:0
|
作者
Erlandsson, Kjell [1 ]
Thomas, Benjamin [1 ]
Dickson, John [1 ]
Hutton, Brian F. [1 ]
机构
[1] UCL, Inst Nucl Med, London, England
关键词
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Partial volume correction (PVC) can compensate for cross-talk between different anatomical regions in images from a functional imaging system with poor spatial resolution, such as PET or SPECT, by utilizing data from a high-resolution structural imaging modality, such as CT or MRI. We have developed a new PVC method for SPECT, and here we present an evaluation of this method using clinical data from [I-123]-FP-CIT (DATscan) studies. PVC was performed based on MRI data, which were segmented and co-registered to the SPECT data. The correction was applied during OSEM reconstruction, taking into account the distance dependent resolution of the SPECT system. We compared our new method (OSEM-PVC) with OSEM reconstruction with resolution recovery (OSEM-RR). Qualitatively, OSEM-PVC resulted in images with visually improved structural definition and, quantitatively, it gave similar contrast as OSEM-RR but lower intra-region variability.
引用
收藏
页码:2687 / 2690
页数:4
相关论文
共 50 条
  • [31] Evaluation of tacrolimus sorption to PVC- and non-PVC-based tubes in administration sets: Pump method vs. drip method
    Jin, Su-Eon
    Jeon, Seungho
    Byon, Hyo-Jin
    Hwang, Sung-Joo
    INTERNATIONAL JOURNAL OF PHARMACEUTICS, 2017, 528 (1-2) : 172 - 179
  • [32] Evaluation of a data acquisition system for SPECT (PET)
    Stenstrom, P
    Rillbert, A
    Habte, F
    Bohm, C
    Larsson, SA
    1999 IEEE NUCLEAR SCIENCE SYMPOSIUM - CONFERENCE RECORD, VOLS 1-3, 1999, : 1332 - 1336
  • [33] Evaluation of a data acquisition system for SPECT (PET)
    Stenstrom, P
    Rillbert, A
    Habte, F
    Bohm, C
    Larsson, SA
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2000, 47 (04) : 1655 - 1659
  • [34] A comparative study of AML, NEGML and OSEM based on experimental and clinical 90Y-PET data using the CASToR platform
    Millardet, Mael
    Moussaoui, Said
    Mateus, Diana
    Idier, Jerome
    Conti, Maurizio
    Carlier, Thomas
    2018 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE PROCEEDINGS (NSS/MIC), 2018,
  • [35] Artificial intelligence based SPECT attenuation correction. Feasibility study and performance evaluation on clinical SPECT images.
    Szolikova, Melinda
    Kovacs, Akos
    Meszaros, Nora
    Garai, Ildiko
    Nagy, Ferenc
    Barna, Sandor
    JOURNAL OF NUCLEAR MEDICINE, 2023, 64
  • [36] Evaluation of a SPECT attenuation correction method using CT data registered with automatic registration software
    Motomura, N
    Takahashi, M
    Nakagawara, G
    Iida, H
    2003 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORD, VOLS 1-5, 2004, : 2676 - 2680
  • [37] Evaluation of effects on noise suppression for SPECT images using advanced projection data interpolation method
    Okura, Y.
    Yamamoto, M.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2012, 39 : S633 - S634
  • [38] Half-dose WBR MIBG cardiac SPECT: clinical evaluation of resolution recovery method
    Pena, H.
    Guilhermina, G.
    Wilk, M.
    Srour, Y.
    Godinho, F.
    EUROPEAN HEART JOURNAL SUPPLEMENTS, 2011, 13 (0A) : A38 - A38
  • [39] Noise correlation in PET, CT, SPECT, and PET/CT data evaluated using autocorrelation function: A phantom study on data, reconstructed using FBP and OSEM
    Razifar P.
    Sandström M.
    Schnieder H.
    Långström B.
    Maripuu E.
    Bengtsson E.
    Bergström M.
    BMC Medical Imaging, 5 (1)
  • [40] First Experience with PVC Localization from Clinical Data
    Svehlikova, J.
    Punshchykova, O.
    Kromkova, K.
    Tysler, M.
    Hatala, R.
    2017 11TH INTERNATIONAL CONFERENCE ON MEASUREMENT, 2017, : 213 - 216