Evaluation of an OSEM-based PVC method for SPECT with clinical data

被引:0
|
作者
Erlandsson, Kjell [1 ]
Thomas, Benjamin [1 ]
Dickson, John [1 ]
Hutton, Brian F. [1 ]
机构
[1] UCL, Inst Nucl Med, London, England
关键词
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Partial volume correction (PVC) can compensate for cross-talk between different anatomical regions in images from a functional imaging system with poor spatial resolution, such as PET or SPECT, by utilizing data from a high-resolution structural imaging modality, such as CT or MRI. We have developed a new PVC method for SPECT, and here we present an evaluation of this method using clinical data from [I-123]-FP-CIT (DATscan) studies. PVC was performed based on MRI data, which were segmented and co-registered to the SPECT data. The correction was applied during OSEM reconstruction, taking into account the distance dependent resolution of the SPECT system. We compared our new method (OSEM-PVC) with OSEM reconstruction with resolution recovery (OSEM-RR). Qualitatively, OSEM-PVC resulted in images with visually improved structural definition and, quantitatively, it gave similar contrast as OSEM-RR but lower intra-region variability.
引用
收藏
页码:2687 / 2690
页数:4
相关论文
共 50 条
  • [41] Evaluation of Functionalized Polysaccharide Microparticles Dosimetry for SPECT Imaging Based on Biodistribution Data of Rats
    Aurélie Desbrée
    Thomas Bonnard
    Eric Blanchardon
    Anne Petiet
    Didier Franck
    Cedric Chauvierre
    Catherine Le Visage
    Molecular Imaging and Biology, 2015, 17 : 504 - 511
  • [42] Evaluation of Functionalized Polysaccharide Microparticles Dosimetry for SPECT Imaging Based on Biodistribution Data of Rats
    Desbree, Aurelie
    Bonnard, Thomas
    Blanchardon, Eric
    Petiet, Anne
    Franck, Didier
    Chauvierre, Cedric
    Le Visage, Catherine
    MOLECULAR IMAGING AND BIOLOGY, 2015, 17 (04) : 504 - 511
  • [43] Millisecond SPECT Image Reconstruction Acceleration using OSEM Algorithm Based on CPU/GPU Hybrid Parallel Hardware Platform
    Wang, Qiulin
    Chen, Si
    Li, Xingdong
    Wang, Kun
    Wang, Shi
    Ma, Tianyu
    Liu, Yaqiang
    2014 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2014,
  • [44] Performance evaluation of a new CZT-based pre-clinical SPECT system
    Park, Sujin
    Yu, A. Ram
    Choi, Yun Young
    Kim, Hee-Joung
    JOURNAL OF NUCLEAR MEDICINE, 2014, 55
  • [45] Performance evaluation of a new CZT-based pre-clinical SPECT system
    Park, Sujin
    Yu, A. Ram
    Choi, Yun Young
    Kim, Hee-Joung
    JOURNAL OF NUCLEAR MEDICINE, 2014, 55
  • [46] Bioavailability assessment from pharmacologic data: Method and clinical evaluation
    Stagni, G
    Shepherd, AMM
    Liu, Y
    Gillespie, WR
    JOURNAL OF PHARMACOKINETICS AND BIOPHARMACEUTICS, 1997, 25 (03): : 349 - 362
  • [47] Bioavailability Assessment from Pharmacologic Data: Method and Clinical Evaluation
    Grazia Stagni
    Alexander M. M. Shepherd
    Yanjuan Liu
    William R. Gillespie
    Journal of Pharmacokinetics and Biopharmaceutics, 1997, 25 : 349 - 362
  • [48] A Reconstruction Method based on a Data Analysis Scheme for SPECT Imaging in Parkinson's Disease
    Koutsantonis, Loizos
    Lemesios, Christos
    Papanicolas, Costas N.
    2017 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2017,
  • [49] Quantitative accuracy of clinical Tc-99m SPECT/CT using OSEM-3D with attenuation and scatter correction
    Zeintl, Johannes
    Vija, Alexander
    Yahil, Amos
    Hornegger, Joachim
    Kuwert, Torsten
    JOURNAL OF NUCLEAR MEDICINE, 2010, 51
  • [50] Evaluation of lifetime of PVC films using the thermogravimetric method
    Rudnik, E
    Dobkowski, Z
    Winiarska, A
    POLIMERY, 1996, 41 (03) : 157 - 160