Prospective respiratory motion correction for coronary MR angiography using a 2D image navigator

被引:39
|
作者
Henningsson, Markus [1 ]
Smink, Jouke [2 ]
Razavi, Reza [1 ]
Botnar, Rene M. [1 ,3 ,4 ,5 ,6 ]
机构
[1] Kings Coll London, Div Imaging Sci & Biomed Engn, London WC2R 2LS, England
[2] Philips Healthcare, Best, Netherlands
[3] Kings Coll London, Wellcome Trust, London WC2R 2LS, England
[4] Kings Coll London, EPSRC Med Engn Ctr, London WC2R 2LS, England
[5] Kings Coll London, BHF Ctr Excellence, London WC2R 2LS, England
[6] Kings Coll London, NIHR Biomed Res Ctr, London WC2R 2LS, England
基金
英国工程与自然科学研究理事会;
关键词
respiratory motion correction; coronary MR angiography; 2D navigator; prospective motion correction; MAGNETIC-RESONANCE ANGIOGRAPHY; ARTERY MOTION; HEART; RECONSTRUCTION; COMPENSATION; ALGORITHM;
D O I
10.1002/mrm.24280
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Respiratory motion remains the major impediment in a substantial amount of patients undergoing coronary magnetic resonance angiography. Motion correction in coronary magnetic resonance angiography is typically performed with a diaphragmatic 1D navigator (1Dnav) assuming a constant linear relationship between diaphragmatic and cardiac respiratory motion. In this work, a novel 2D navigator (2Dnav) is proposed, which prospectively corrects for translational motion in foothead and leftright direction. First, 1Dnav- and 2Dnav-based motion correction are compared in 2D real time imaging experiments, by evaluating the residual respiratory motion in 10 healthy subjects as well as in a moving vessel phantom. Subsequently, 1Dnav and 2Dnav corrected high-resolution 3D coronary MR angiograms were acquired, and both objective and subjective image quality were assessed. For a gating window of 10 mm, 1Dnav and 2Dnav performed equally well; however, without any respiratory gating, the 1Dnav had a lower visual score for all coronary arteries compared with 10 mm gating, whereas the 2Dnav without gating performed similar to 1Dnav with 10 mm gating. Magn Reson Med, 2013. (C) 2012 Wiley Periodicals, Inc.
引用
收藏
页码:486 / 494
页数:9
相关论文
共 50 条
  • [1] Prospective navigator correction of image position for coronary MR angiography
    Danias, PG
    McConnell, MV
    Khasgiwala, VC
    Chuang, ML
    Edelman, RR
    Manning, WJ
    RADIOLOGY, 1997, 203 (03) : 733 - 736
  • [2] Direct Coronary Motion Extraction from a 2D Fat Image Navigator for Prospectively Gated Coronary MR Angiography
    Kawaji, Keigo
    Spincemaille, Pascal
    Nguyen, Thanh D.
    Thimmappa, Nandadeepa
    Cooper, Mitchell A.
    Prince, Martin R.
    Wang, Yi
    MAGNETIC RESONANCE IN MEDICINE, 2014, 71 (02) : 599 - 607
  • [3] Model evaluation and calibration for prospective respiratory motion correction in coronary MR angiography based on 3-D image registration
    Manke, D
    Rösch, P
    Nehrke, K
    Börnert, P
    Dössel, O
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2002, 21 (09) : 1132 - 1141
  • [4] A comparison of prospective and retrospective respiratory navigator gating in 3D MR coronary angiography
    Du, YPP
    McVeigh, ER
    Bluemke, DA
    Silber, HA
    Foo, TKF
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2001, 17 (04): : 287 - 294
  • [5] A comparison of prospective and retrospective respiratory navigator gating in 3D MR coronary angiography
    Yiping P. Du
    Elliot R. McVeigh
    David A. Bluemke
    Harry A. Silber
    Thomas K.F. Foo
    The International Journal of Cardiovascular Imaging, 2001, 17 : 287 - 294
  • [6] Coronary MR angiography: Respiratory motion correction with BACSPIN
    Hardy, CJ
    Zhao, L
    Zong, XL
    Saranathan, M
    Yucel, EK
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2003, 17 (02) : 170 - 176
  • [7] Prospective adaptive navigator correction for breath-hold MR coronary angiography
    McConnell, MV
    Khasgiwala, VC
    Savord, BJ
    Chen, MH
    Chuang, ML
    Edelman, RR
    Manning, WJ
    MAGNETIC RESONANCE IN MEDICINE, 1997, 37 (01) : 148 - 152
  • [8] Retrospective adaptive motion correction for navigator-gated 3D coronary MR angiography
    Wang, Y
    Ehman, RL
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2000, 11 (02) : 208 - 214
  • [9] Properties of a 2D Fat Navigator for Prospective Image Domain Correction of Nodding Motion in Brain MRI
    Skare, Stefan
    Hartwig, Axel
    Martensson, Magnus
    Avventi, Enrico
    Engstrom, Mathias
    MAGNETIC RESONANCE IN MEDICINE, 2015, 73 (03) : 1110 - 1119
  • [10] Prospective navigator gating with a dual acceptance window technique to reduce respiratory motion artifacts in 3D MR coronary angiography
    Yiping P. Du
    The International Journal of Cardiovascular Imaging, 2003, 19 : 157 - 162