Prospective respiratory motion correction for coronary MR angiography using a 2D image navigator

被引:39
|
作者
Henningsson, Markus [1 ]
Smink, Jouke [2 ]
Razavi, Reza [1 ]
Botnar, Rene M. [1 ,3 ,4 ,5 ,6 ]
机构
[1] Kings Coll London, Div Imaging Sci & Biomed Engn, London WC2R 2LS, England
[2] Philips Healthcare, Best, Netherlands
[3] Kings Coll London, Wellcome Trust, London WC2R 2LS, England
[4] Kings Coll London, EPSRC Med Engn Ctr, London WC2R 2LS, England
[5] Kings Coll London, BHF Ctr Excellence, London WC2R 2LS, England
[6] Kings Coll London, NIHR Biomed Res Ctr, London WC2R 2LS, England
基金
英国工程与自然科学研究理事会;
关键词
respiratory motion correction; coronary MR angiography; 2D navigator; prospective motion correction; MAGNETIC-RESONANCE ANGIOGRAPHY; ARTERY MOTION; HEART; RECONSTRUCTION; COMPENSATION; ALGORITHM;
D O I
10.1002/mrm.24280
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Respiratory motion remains the major impediment in a substantial amount of patients undergoing coronary magnetic resonance angiography. Motion correction in coronary magnetic resonance angiography is typically performed with a diaphragmatic 1D navigator (1Dnav) assuming a constant linear relationship between diaphragmatic and cardiac respiratory motion. In this work, a novel 2D navigator (2Dnav) is proposed, which prospectively corrects for translational motion in foothead and leftright direction. First, 1Dnav- and 2Dnav-based motion correction are compared in 2D real time imaging experiments, by evaluating the residual respiratory motion in 10 healthy subjects as well as in a moving vessel phantom. Subsequently, 1Dnav and 2Dnav corrected high-resolution 3D coronary MR angiograms were acquired, and both objective and subjective image quality were assessed. For a gating window of 10 mm, 1Dnav and 2Dnav performed equally well; however, without any respiratory gating, the 1Dnav had a lower visual score for all coronary arteries compared with 10 mm gating, whereas the 2Dnav without gating performed similar to 1Dnav with 10 mm gating. Magn Reson Med, 2013. (C) 2012 Wiley Periodicals, Inc.
引用
收藏
页码:486 / 494
页数:9
相关论文
共 50 条
  • [21] Respiratory Motion Correction for 2D Cine Cardiac MR Images using Probabilistic Edge Maps
    Oktay, O.
    Tarroni, G.
    Bai, W.
    de Marvao, A.
    O'Regan, D.
    Cook, S.
    Rueckert, D.
    2016 COMPUTING IN CARDIOLOGY CONFERENCE (CINC), VOL 43, 2016, 43 : 129 - 132
  • [22] Advanced Respiratory Motion Compensation for Coronary MR Angiography
    Henningsson, Markus
    Botnar, Rene M.
    SENSORS, 2013, 13 (06) : 6882 - 6899
  • [23] Whole-heart T1 mapping using a 2D fat image navigator for respiratory motion compensation
    Nordio, Giovanna
    Schneider, Torben
    Cruz, Gastao
    Correia, Teresa
    Bustin, Aurelien
    Prieto, Claudia
    Botnar, Rene M.
    Henningsson, Markus
    MAGNETIC RESONANCE IN MEDICINE, 2020, 83 (01) : 178 - 187
  • [24] Three-dimensional MR coronary angiography using the navigator technique compared with conventional coronary angiography
    Sandstede, JJW
    Pabst, T
    Beer, M
    Geis, N
    Kenn, W
    Neubauer, S
    Hahn, D
    AMERICAN JOURNAL OF ROENTGENOLOGY, 1999, 172 (01) : 135 - 139
  • [25] Whole-heart coronary MR angiography with 2D self-navigated image reconstruction
    Henningsson, Markus
    Koken, Peter
    Stehning, Christian
    Razavi, Reza
    Prieto, Claudia
    Botnar, Rene M.
    MAGNETIC RESONANCE IN MEDICINE, 2012, 67 (02) : 437 - 445
  • [26] Comparison of Image-Based and Reconstruction-Based Respiratory Motion Correction for Golden Radial Phase Encoding Coronary MR Angiography
    Paschke, Nadia K.
    Doessel, Olaf
    Schaeffter, Tobias
    Prieto, Claudia
    Kolbitsch, Christoph
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2015, 42 (04) : 964 - 971
  • [27] Submillimeter three-dimensional coronary MR angiography with real-time navigator correction: Comparison of navigator locations
    Stuber, M
    Botnar, RM
    Danias, PG
    Kissinger, KV
    Manning, WJ
    RADIOLOGY, 1999, 212 (02) : 579 - 587
  • [28] Thoracic respiratory motion estimation from MRI using a statistical model and a 2-D image navigator
    King, A. P.
    Buerger, C.
    Tsoumpas, C.
    Marsden, P. K.
    Schaeffter, T.
    MEDICAL IMAGE ANALYSIS, 2012, 16 (01) : 252 - 264
  • [29] Nonrigid Autofocus Motion Correction for Coronary MR Angiography with a 3D Cones Trajectory
    Ingle, R. Reeve
    Wu, Holden H.
    Addy, Nii Okai
    Cheng, Joseph Y.
    Yang, Phillip C.
    Hu, Bob S.
    Nishimura, Dwight G.
    MAGNETIC RESONANCE IN MEDICINE, 2014, 72 (02) : 347 - 361
  • [30] Prospective motion correction in 2D multishot MRI using EPI navigators and multislice-to-volume image registration
    Hoinkiss, Daniel Christopher
    Porter, David Andrew
    MAGNETIC RESONANCE IN MEDICINE, 2017, 78 (06) : 2127 - 2135