Prospective respiratory motion correction for coronary MR angiography using a 2D image navigator

被引:39
|
作者
Henningsson, Markus [1 ]
Smink, Jouke [2 ]
Razavi, Reza [1 ]
Botnar, Rene M. [1 ,3 ,4 ,5 ,6 ]
机构
[1] Kings Coll London, Div Imaging Sci & Biomed Engn, London WC2R 2LS, England
[2] Philips Healthcare, Best, Netherlands
[3] Kings Coll London, Wellcome Trust, London WC2R 2LS, England
[4] Kings Coll London, EPSRC Med Engn Ctr, London WC2R 2LS, England
[5] Kings Coll London, BHF Ctr Excellence, London WC2R 2LS, England
[6] Kings Coll London, NIHR Biomed Res Ctr, London WC2R 2LS, England
基金
英国工程与自然科学研究理事会;
关键词
respiratory motion correction; coronary MR angiography; 2D navigator; prospective motion correction; MAGNETIC-RESONANCE ANGIOGRAPHY; ARTERY MOTION; HEART; RECONSTRUCTION; COMPENSATION; ALGORITHM;
D O I
10.1002/mrm.24280
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Respiratory motion remains the major impediment in a substantial amount of patients undergoing coronary magnetic resonance angiography. Motion correction in coronary magnetic resonance angiography is typically performed with a diaphragmatic 1D navigator (1Dnav) assuming a constant linear relationship between diaphragmatic and cardiac respiratory motion. In this work, a novel 2D navigator (2Dnav) is proposed, which prospectively corrects for translational motion in foothead and leftright direction. First, 1Dnav- and 2Dnav-based motion correction are compared in 2D real time imaging experiments, by evaluating the residual respiratory motion in 10 healthy subjects as well as in a moving vessel phantom. Subsequently, 1Dnav and 2Dnav corrected high-resolution 3D coronary MR angiograms were acquired, and both objective and subjective image quality were assessed. For a gating window of 10 mm, 1Dnav and 2Dnav performed equally well; however, without any respiratory gating, the 1Dnav had a lower visual score for all coronary arteries compared with 10 mm gating, whereas the 2Dnav without gating performed similar to 1Dnav with 10 mm gating. Magn Reson Med, 2013. (C) 2012 Wiley Periodicals, Inc.
引用
收藏
页码:486 / 494
页数:9
相关论文
共 50 条
  • [31] Repeated 3D coronary MR angiography with navigator echo gating: Technical quality and consistency of image interpretation
    Ikonen, AEJ
    Manninen, HI
    Vainio, P
    Hirvonen, TPJ
    Vanninen, RL
    Matsi, PJ
    Hartikainen, JEK
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2000, 24 (03) : 375 - 381
  • [32] High Efficiency Coronary MR Angiography with Nonrigid Cardiac Motion Correction
    Pang, Jianing
    Chen, Yuhua
    Fan, Zhaoyang
    Nguyen, Christopher
    Yang, Qi
    Xie, Yibin
    Li, Debiao
    MAGNETIC RESONANCE IN MEDICINE, 2016, 76 (05) : 1345 - 1353
  • [33] Three-dimensional coronary artery MR imaging using prospective real-time respiratory navigator and linear phase shift processing: Comparison with conventional coronary angiography
    Lethimonnier, F
    Furber, A
    Morel, O
    Geslin, P
    L'Hoste, P
    Tadei, A
    Jallet, P
    Caron-Poitreau, C
    Le Jeune, JJ
    MAGNETIC RESONANCE IMAGING, 1999, 17 (08) : 1111 - 1120
  • [34] MR Image-based PET Respiratory Motion Correction in PET/MR
    Manber, Richard
    Thielemans, Kris
    Hutton, Brian
    Barnes, Anna
    Ourselin, Sebastien
    Arridge, Simon
    Wan, Ming Young Simon
    O'Meara, Celia
    Atkinson, David
    JOURNAL OF NUCLEAR MEDICINE, 2015, 56 (03)
  • [35] Spherical navigator registration using harmonic analysis for prospective motion correction
    Wyatt, CL
    Ari, N
    Kraft, RA
    INFORMATION PROCESSING IN MEDICAL IMAGING, PROCEEDINGS, 2005, 3565 : 738 - 749
  • [36] Submillimeter 3D coronary MR angiography with real-time navigator correction in 107 patients with suspected coronary artery disease
    Sommer, T
    Hofer, U
    Hackenbroch, M
    Meyer, C
    Flacke, S
    Schmiedel, A
    Schmitz, C
    Thiemann, K
    Omran, H
    Schild, H
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2002, 174 (04): : 459 - 466
  • [37] Repspiratory motion correction with a 2d self-navigator from bssfp dummy profiles
    Markus Henningsson
    Peter Koken
    Christian Stehning
    Claudia Prieto
    René M Botnar
    Journal of Cardiovascular Magnetic Resonance, 13 (Suppl 1)
  • [38] Respiratory and cardiac motion correction for cardiac PET based on 2D-MRI image navigator and novel dynamic reconstruction technique
    Zhu, Xucheng
    Gu, Wenbo
    Ying, Kui
    2015 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2015,
  • [39] Image-based 3D non-rigid respiratory motion correction for free-breathing thoracic MR angiography
    Fei Han
    Cheng Ouyang
    Ziwu Zhou
    Paul J Finn
    Peng Hu
    Journal of Cardiovascular Magnetic Resonance, 18 (Suppl 1)
  • [40] Prospective evaluation of peripheral arterial occlusive disease by 2D MR subtraction angiography
    Laissy, JP
    Debray, MP
    Menegazzo, D
    Rangheard, AS
    Benamer, H
    Charlier, P
    Schouman-Claeys, E
    JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1998, 8 (05): : 1060 - 1065