Prospective respiratory motion correction for coronary MR angiography using a 2D image navigator

被引:39
|
作者
Henningsson, Markus [1 ]
Smink, Jouke [2 ]
Razavi, Reza [1 ]
Botnar, Rene M. [1 ,3 ,4 ,5 ,6 ]
机构
[1] Kings Coll London, Div Imaging Sci & Biomed Engn, London WC2R 2LS, England
[2] Philips Healthcare, Best, Netherlands
[3] Kings Coll London, Wellcome Trust, London WC2R 2LS, England
[4] Kings Coll London, EPSRC Med Engn Ctr, London WC2R 2LS, England
[5] Kings Coll London, BHF Ctr Excellence, London WC2R 2LS, England
[6] Kings Coll London, NIHR Biomed Res Ctr, London WC2R 2LS, England
基金
英国工程与自然科学研究理事会;
关键词
respiratory motion correction; coronary MR angiography; 2D navigator; prospective motion correction; MAGNETIC-RESONANCE ANGIOGRAPHY; ARTERY MOTION; HEART; RECONSTRUCTION; COMPENSATION; ALGORITHM;
D O I
10.1002/mrm.24280
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Respiratory motion remains the major impediment in a substantial amount of patients undergoing coronary magnetic resonance angiography. Motion correction in coronary magnetic resonance angiography is typically performed with a diaphragmatic 1D navigator (1Dnav) assuming a constant linear relationship between diaphragmatic and cardiac respiratory motion. In this work, a novel 2D navigator (2Dnav) is proposed, which prospectively corrects for translational motion in foothead and leftright direction. First, 1Dnav- and 2Dnav-based motion correction are compared in 2D real time imaging experiments, by evaluating the residual respiratory motion in 10 healthy subjects as well as in a moving vessel phantom. Subsequently, 1Dnav and 2Dnav corrected high-resolution 3D coronary MR angiograms were acquired, and both objective and subjective image quality were assessed. For a gating window of 10 mm, 1Dnav and 2Dnav performed equally well; however, without any respiratory gating, the 1Dnav had a lower visual score for all coronary arteries compared with 10 mm gating, whereas the 2Dnav without gating performed similar to 1Dnav with 10 mm gating. Magn Reson Med, 2013. (C) 2012 Wiley Periodicals, Inc.
引用
收藏
页码:486 / 494
页数:9
相关论文
共 50 条
  • [41] Respiratory Motion Correction of PET using Motion Parameters from MR
    Dikaios, Nikolaos
    Fryer, Tim D.
    2009 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2009, : 2806 - 2808
  • [42] MR coronary artery imaging with 3D motion adapted gating (MAG) in comparison to a standard prospective navigator technique
    Langreck, H
    Schnackenburg, B
    Nehrke, K
    Boernert, P
    Wahl, A
    Paetsch, I
    Bornstedt, A
    Fleck, E
    Nagel, E
    JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2005, 7 (05) : 793 - 797
  • [43] Optimized respiratory-resolved motion-compensated 3D Cartesian coronary MR angiography
    Correia, Teresa
    Ginami, Giulia
    Cruz, Gastao
    Neji, Radhouene
    Rashid, Imran
    Botnar, Rene M.
    Prieto, Claudia
    MAGNETIC RESONANCE IN MEDICINE, 2018, 80 (06) : 2618 - 2629
  • [44] Optimization of realtime adaptive navigator correction for 3D magnetic resonance coronary angiography
    Nagel, E
    Bornstedt, A
    Schnackenburg, B
    Hug, J
    Oswald, H
    Fleck, E
    MAGNETIC RESONANCE IN MEDICINE, 1999, 42 (02) : 408 - 411
  • [45] Implications of respiratory motion for the quantification of 2D MR spectroscopic imaging data in the abdomen
    Schwarz, AJ
    Leach, MO
    PHYSICS IN MEDICINE AND BIOLOGY, 2000, 45 (08): : 2105 - 2116
  • [46] Phased Attenuation Correction and Respiratory Motion Compensation of PET Image by Using a CT Image and Multiple Respiratory-Phase MR Images
    Nam, Woo Hyun
    Lee, Duhgoon
    Ahn, Il Jun
    Jeong, Kye Young
    Kim, Ji Hye
    Ra, Jong Beom
    2011 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2011, : 3792 - 3795
  • [47] 3D motion adapted gating (3D MAG): a new navigator technique for accelerated acquisition of free breathing navigator gated 3D coronary MR-angiography
    Hackenbroch, M
    Nehrke, K
    Gieseke, J
    Meyer, C
    Tiemann, K
    Litt, H
    Dewald, O
    Naehle, CP
    Schild, H
    Sommer, T
    EUROPEAN RADIOLOGY, 2005, 15 (08) : 1598 - 1606
  • [48] Evaluation of coronary arterial stenoses using 2D magnetic resonance coronary angiography
    Yamada, T
    Sawada, T
    Yamano, T
    Azuma, A
    Nakagawa, M
    MINIMALLY INVASIVE THERAPY & ALLIED TECHNOLOGIES, 2002, 11 (01) : 7 - 15
  • [49] 3D motion adapted gating (3D MAG): a new navigator technique for accelerated acquisition of free breathing navigator gated 3D coronary MR-angiography
    M. Hackenbroch
    K. Nehrke
    J. Gieseke
    C. Meyer
    K. Tiemann
    H. Litt
    O. Dewald
    C. P. Naehle
    H. Schild
    T. Sommer
    European Radiology, 2005, 15 : 1598 - 1606
  • [50] 3D navigator echo MR coronary angiography (MRCA) in detecting stenoses of major epicardial coronary arteries
    Sardanelli, F
    Parodi, RC
    Molinari, G
    Guglielmino, G
    Rescinito, G
    Caponnetto, S
    RADIOLOGY, 1997, 205 : 51 - 51