Direct Coronary Motion Extraction from a 2D Fat Image Navigator for Prospectively Gated Coronary MR Angiography

被引:22
|
作者
Kawaji, Keigo [1 ,2 ]
Spincemaille, Pascal [2 ]
Nguyen, Thanh D. [2 ]
Thimmappa, Nandadeepa [2 ]
Cooper, Mitchell A. [1 ,2 ]
Prince, Martin R. [2 ]
Wang, Yi [1 ,2 ]
机构
[1] Cornell Univ, Dept Biomed Engn, Ithaca, NY USA
[2] Weill Cornell Med Coll, Dept Radiol, New York, NY USA
关键词
coronary MR angiography; cardiac fat navigator; 2D navigator; real-time motion extraction; respiratory gating; MAGNETIC-RESONANCE ANGIOGRAPHY; RESPIRATORY MOTION; SELECTIVE EXCITATION; ARTERY MOTION; RADIAL SSFP; HEART; RECONSTRUCTION; ACQUISITION; EFFICIENCY; RESOLUTION;
D O I
10.1002/mrm.24698
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PurposeDirect 2D tracking of cardiac motion may provide superior respiratory navigator gating for coronary magnetic resonance angiography compared to conventional liver-diaphragm navigators. However, additional 2D processing for motion extraction is unsuitable for real-time prospective gating. In this work, a 2D fat-selective image navigator, which delineates the epicardial fat surrounding coronary arteries, is developed to directly monitor epicardial fat motion at every heartbeat in real-time for prospective gating. MethodsThe proposed navigator is incorporated into a real-time interactive software that allows rapid setup and efficient motion extraction, and runs on standard clinical hardware without any additional dedicated components for processing. The proposed 2D cardiac fat image navigator was compared with the conventional 1D diaphragm navigator in free-breathing b-SSFP coronary MRAs in 12 healthy volunteers at 1.5T. ResultsReal-time motion extraction from 2D cardiac fat navigator images was feasible within 20 ms, enabling successful prospectively gated coronary magnetic resonance angiographies in all subjects. Compared to 1D diaphragmatic navigator, 2D fat image navigator reduced scan time by 38% (P<0.0005), and significantly improved vessel sharpness, myocardial suppression, and image quality (P<0.05). ConclusionThis demonstrates the feasibility of a 3D SSFP coronary magnetic resonance angiography sequence using a 2D epicardial fat image as a navigator for real-time prospective motion tracking. Magn Reson Med 71:599-607, 2014. (c) 2013 Wiley Periodicals, Inc.
引用
收藏
页码:599 / 607
页数:9
相关论文
共 50 条
  • [1] Prospective respiratory motion correction for coronary MR angiography using a 2D image navigator
    Henningsson, Markus
    Smink, Jouke
    Razavi, Reza
    Botnar, Rene M.
    MAGNETIC RESONANCE IN MEDICINE, 2013, 69 (02) : 486 - 494
  • [2] Retrospective adaptive motion correction for navigator-gated 3D coronary MR angiography
    Wang, Y
    Ehman, RL
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2000, 11 (02) : 208 - 214
  • [3] Prospective navigator correction of image position for coronary MR angiography
    Danias, PG
    McConnell, MV
    Khasgiwala, VC
    Chuang, ML
    Edelman, RR
    Manning, WJ
    RADIOLOGY, 1997, 203 (03) : 733 - 736
  • [4] Real-time, navigator-gated, adaptively corrected 3D coronary MR angiography
    Wang, Y
    Johnston, DL
    Riederer, SJ
    Ehman, RL
    RADIOLOGY, 1996, 201 : 351 - 351
  • [5] Direct monitoring of coronary artery motion with cardiac fat navigator echoes
    Nguyen, TD
    Nuval, A
    Mulukutla, S
    Wang, Y
    MAGNETIC RESONANCE IN MEDICINE, 2003, 50 (02) : 235 - 241
  • [6] Dose and image quality comparison between prospectively gated axial and retrospectively gated helical coronary CT angiography
    Hlaihel, C.
    Boussel, L.
    Cochet, H.
    Roch, J. A.
    Coulon, P.
    Walker, M. J.
    Douek, P. C.
    BRITISH JOURNAL OF RADIOLOGY, 2011, 84 (997): : 51 - 57
  • [7] Whole-heart coronary MR angiography with 2D self-navigated image reconstruction
    Henningsson, Markus
    Koken, Peter
    Stehning, Christian
    Razavi, Reza
    Prieto, Claudia
    Botnar, Rene M.
    MAGNETIC RESONANCE IN MEDICINE, 2012, 67 (02) : 437 - 445
  • [8] 3D motion adapted gating (3D MAG): a new navigator technique for accelerated acquisition of free breathing navigator gated 3D coronary MR-angiography
    Hackenbroch, M
    Nehrke, K
    Gieseke, J
    Meyer, C
    Tiemann, K
    Litt, H
    Dewald, O
    Naehle, CP
    Schild, H
    Sommer, T
    EUROPEAN RADIOLOGY, 2005, 15 (08) : 1598 - 1606
  • [9] 3D motion adapted gating (3D MAG): a new navigator technique for accelerated acquisition of free breathing navigator gated 3D coronary MR-angiography
    M. Hackenbroch
    K. Nehrke
    J. Gieseke
    C. Meyer
    K. Tiemann
    H. Litt
    O. Dewald
    C. P. Naehle
    H. Schild
    T. Sommer
    European Radiology, 2005, 15 : 1598 - 1606
  • [10] Repeated 3D coronary MR angiography with navigator echo gating: Technical quality and consistency of image interpretation
    Ikonen, AEJ
    Manninen, HI
    Vainio, P
    Hirvonen, TPJ
    Vanninen, RL
    Matsi, PJ
    Hartikainen, JEK
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2000, 24 (03) : 375 - 381