Direct Coronary Motion Extraction from a 2D Fat Image Navigator for Prospectively Gated Coronary MR Angiography

被引:22
|
作者
Kawaji, Keigo [1 ,2 ]
Spincemaille, Pascal [2 ]
Nguyen, Thanh D. [2 ]
Thimmappa, Nandadeepa [2 ]
Cooper, Mitchell A. [1 ,2 ]
Prince, Martin R. [2 ]
Wang, Yi [1 ,2 ]
机构
[1] Cornell Univ, Dept Biomed Engn, Ithaca, NY USA
[2] Weill Cornell Med Coll, Dept Radiol, New York, NY USA
关键词
coronary MR angiography; cardiac fat navigator; 2D navigator; real-time motion extraction; respiratory gating; MAGNETIC-RESONANCE ANGIOGRAPHY; RESPIRATORY MOTION; SELECTIVE EXCITATION; ARTERY MOTION; RADIAL SSFP; HEART; RECONSTRUCTION; ACQUISITION; EFFICIENCY; RESOLUTION;
D O I
10.1002/mrm.24698
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PurposeDirect 2D tracking of cardiac motion may provide superior respiratory navigator gating for coronary magnetic resonance angiography compared to conventional liver-diaphragm navigators. However, additional 2D processing for motion extraction is unsuitable for real-time prospective gating. In this work, a 2D fat-selective image navigator, which delineates the epicardial fat surrounding coronary arteries, is developed to directly monitor epicardial fat motion at every heartbeat in real-time for prospective gating. MethodsThe proposed navigator is incorporated into a real-time interactive software that allows rapid setup and efficient motion extraction, and runs on standard clinical hardware without any additional dedicated components for processing. The proposed 2D cardiac fat image navigator was compared with the conventional 1D diaphragm navigator in free-breathing b-SSFP coronary MRAs in 12 healthy volunteers at 1.5T. ResultsReal-time motion extraction from 2D cardiac fat navigator images was feasible within 20 ms, enabling successful prospectively gated coronary magnetic resonance angiographies in all subjects. Compared to 1D diaphragmatic navigator, 2D fat image navigator reduced scan time by 38% (P<0.0005), and significantly improved vessel sharpness, myocardial suppression, and image quality (P<0.05). ConclusionThis demonstrates the feasibility of a 3D SSFP coronary magnetic resonance angiography sequence using a 2D epicardial fat image as a navigator for real-time prospective motion tracking. Magn Reson Med 71:599-607, 2014. (c) 2013 Wiley Periodicals, Inc.
引用
收藏
页码:599 / 607
页数:9
相关论文
共 50 条
  • [41] An Unsupervised Image Segmentation Workflow for Extraction of Left Coronary Artery from X-Ray Coronary Angiography
    Dasic, Lazar
    Pavic, Ognjen
    Geroski, Tijana
    Filipovic, Nenad
    APPLIED ARTIFICIAL INTELLIGENCE 2: MEDICINE, BIOLOGY, CHEMISTRY, FINANCIAL, GAMES, ENGINEERING, SICAAI 2023, 2024, 999 : 116 - 122
  • [42] SYMPTOMS AT CORONARY ANGIOGRAPHY IN PATIENTS WITH TYPE 2 DIABETES MELLITUS AND STABLE CORONARY ARTERY DISEASE: INSIGHTS FROM BARI 2D
    Krishnaswami, Ashok
    Hardison, Regina M.
    Nesto, Richard W.
    Sobel, Burton
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2011, 57 (14) : E1049 - E1049
  • [43] Imaging of an aberrant right coronary artery with retrospective respiratory-gated 3D-MR angiography
    Kalinkin, OM
    Woodard, PK
    Ludbrook, PA
    Gutierrez, FR
    INTERNATIONAL JOURNAL OF CARDIAC IMAGING, 2001, 17 (01): : 61 - 64
  • [44] Imaging of an aberrant right coronary artery with retrospective respiratory-gated 3D-MR angiography
    Olga M. Kalinkin
    Pamela K. Woodard
    Philip A. Ludbrook
    Fernando R. Gutierrez
    The International Journal of Cardiovascular Imaging, 2001, 17 : 61 - 64
  • [45] Improvement of Image Quality and Diagnostic Performance by an Innovative Motion-Correction Algorithm for Prospectively ECG Triggered Coronary CT Angiography
    Li, Zhen-Nan
    Yin, Wei-Hua
    Lu, Bin
    Yan, Hong-Bing
    Mu, Chao-Wei
    Gao, Yang
    Hou, Zhi-Hui
    Wang, Zhi-Qiang
    Liu, Kun
    Parinella, Ashley H.
    Leipsic, Jonathon A.
    PLOS ONE, 2015, 10 (11):
  • [46] Feasibility of proximal right coronary artery imaging by 2D and 3D echocardiography in comparison to coronary angiography
    Stoebe S.
    Lange K.
    Pfeiffer D.
    Hagendorff A.
    Echo Research & Practice, 2015, 2 (3): : 73 - 79
  • [47] A New Framework for Interleaved Scanning in Cardiovascular MR: Application to Image-Based Respiratory Motion Correction in Coronary MR Angiography
    Henningsson, Markus
    Mens, Giel
    Koken, Peter
    Smink, Jouke
    Botnar, Rene M.
    MAGNETIC RESONANCE IN MEDICINE, 2015, 73 (02) : 692 - 696
  • [48] Direct Comparison of Whole-Heart Navigator-Gated Magnetic Resonance Coronary Angiography and 40-and 64-Slice Multidetector Row Computed Tomography to Detect the Coronary Artery Stenosis in Patients Scheduled for Conventional Coronary Angiography
    Pouleur, Anne-Catherine
    de Waroux, Jean-Benoit le Polain
    Kefer, Joelle
    Pasquet, Agnes
    Vanoverschelde, Jean-Louis
    Gerber, Bernhard L.
    CIRCULATION-CARDIOVASCULAR IMAGING, 2008, 1 (02) : 114 - 121
  • [49] Characterization of 3-D Coronary Tree Motion From MSCT Angiography
    Yang, Guanyu
    Zhou, Jian
    Boulmier, Dominique
    Garcia, Marie-Paule
    Luo, Limin
    Toumoulin, Christine
    IEEE TRANSACTIONS ON INFORMATION TECHNOLOGY IN BIOMEDICINE, 2010, 14 (01): : 101 - 106
  • [50] 4-D Motion Animation of Coronary Arteries from Rotational Angiography
    Holub, Wolfgang
    Rohkohl, Christopher
    Schuldhaus, Dominik
    Pruemmer, Marcus
    Lauritsch, Guenter
    Hornegger, Joachim
    MEDICAL IMAGING 2011: VISUALIZATION, IMAGE-GUIDED PROCEDURES, AND MODELING, 2011, 7964