Direct Coronary Motion Extraction from a 2D Fat Image Navigator for Prospectively Gated Coronary MR Angiography

被引:22
|
作者
Kawaji, Keigo [1 ,2 ]
Spincemaille, Pascal [2 ]
Nguyen, Thanh D. [2 ]
Thimmappa, Nandadeepa [2 ]
Cooper, Mitchell A. [1 ,2 ]
Prince, Martin R. [2 ]
Wang, Yi [1 ,2 ]
机构
[1] Cornell Univ, Dept Biomed Engn, Ithaca, NY USA
[2] Weill Cornell Med Coll, Dept Radiol, New York, NY USA
关键词
coronary MR angiography; cardiac fat navigator; 2D navigator; real-time motion extraction; respiratory gating; MAGNETIC-RESONANCE ANGIOGRAPHY; RESPIRATORY MOTION; SELECTIVE EXCITATION; ARTERY MOTION; RADIAL SSFP; HEART; RECONSTRUCTION; ACQUISITION; EFFICIENCY; RESOLUTION;
D O I
10.1002/mrm.24698
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PurposeDirect 2D tracking of cardiac motion may provide superior respiratory navigator gating for coronary magnetic resonance angiography compared to conventional liver-diaphragm navigators. However, additional 2D processing for motion extraction is unsuitable for real-time prospective gating. In this work, a 2D fat-selective image navigator, which delineates the epicardial fat surrounding coronary arteries, is developed to directly monitor epicardial fat motion at every heartbeat in real-time for prospective gating. MethodsThe proposed navigator is incorporated into a real-time interactive software that allows rapid setup and efficient motion extraction, and runs on standard clinical hardware without any additional dedicated components for processing. The proposed 2D cardiac fat image navigator was compared with the conventional 1D diaphragm navigator in free-breathing b-SSFP coronary MRAs in 12 healthy volunteers at 1.5T. ResultsReal-time motion extraction from 2D cardiac fat navigator images was feasible within 20 ms, enabling successful prospectively gated coronary magnetic resonance angiographies in all subjects. Compared to 1D diaphragmatic navigator, 2D fat image navigator reduced scan time by 38% (P<0.0005), and significantly improved vessel sharpness, myocardial suppression, and image quality (P<0.05). ConclusionThis demonstrates the feasibility of a 3D SSFP coronary magnetic resonance angiography sequence using a 2D epicardial fat image as a navigator for real-time prospective motion tracking. Magn Reson Med 71:599-607, 2014. (c) 2013 Wiley Periodicals, Inc.
引用
收藏
页码:599 / 607
页数:9
相关论文
共 50 条
  • [21] Relationship between beat to beat coronary artery motion and image quality in prospectively ECG-gated two heart beat 320-detector row coronary CT angiography
    Tomizawa, Nobuo
    Komatsu, Shuhei
    Akahane, Masaaki
    Torigoe, Rumiko
    Kiryu, Shigeru
    Ohtomo, Kuni
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2012, 28 (01): : 139 - 146
  • [22] Correlation of 3D MR coronary angiography with selective coronary angiography:: feasibility of the motion-adapted gating technique
    Weber, C
    Steiner, P
    Sinkus, R
    Dill, T
    Börnert, P
    Adam, G
    EUROPEAN RADIOLOGY, 2002, 12 (04) : 718 - 726
  • [23] Correlation of 3D MR coronary angiography with selective coronary angiography: feasibility of the motion-adapted gating technique
    Christoph Weber
    Paul Steiner
    Ralph Sinkus
    Thorsten Dill
    Peter Börnert
    Gerhard Adam
    European Radiology, 2002, 12 : 718 - 726
  • [24] Prospectively gated transverse coronary CT angiography versus retrospectively gated helical technique: Improved image quality and reduced radiation dose
    Earls, James P.
    Berman, Elise L.
    Urban, Bruce A.
    Curry, Charlene A.
    Lane, Judith L.
    Jennings, Robert S.
    McCulloch, Colin C.
    Hsieh, Jiang
    Londt, John H.
    RADIOLOGY, 2008, 246 (03) : 742 - 753
  • [25] 3D image-based navigators for coronary MR angiography
    Addy, Nii Okai
    Ingle, R. Reeve
    Luo, Jieying
    Baron, Corey A.
    Yang, Phillip C.
    Hu, Bob S.
    Nishimura, Dwight G.
    MAGNETIC RESONANCE IN MEDICINE, 2017, 77 (05) : 1874 - 1883
  • [26] Image-based coronary tracking and beat-to-beat motion compensation: Feasibility for improving coronary MR angiography
    Dewan, Maneesh
    Hager, Gregory D.
    Lorenz, Christine H.
    MAGNETIC RESONANCE IN MEDICINE, 2008, 60 (03) : 604 - 615
  • [27] 3D MR coronary angiography vs selective coronary angiography-impact of the novel motion adapted gating technique
    Weber, C
    Steiner, P
    Sinkus, R
    Dill, T
    Boernert, P
    Buecheler, E
    RADIOLOGY, 2000, 217 : 285 - 285
  • [28] Evaluation of coronary arterial stenoses using 2D magnetic resonance coronary angiography
    Yamada, T
    Sawada, T
    Yamano, T
    Azuma, A
    Nakagawa, M
    MINIMALLY INVASIVE THERAPY & ALLIED TECHNOLOGIES, 2002, 11 (01) : 7 - 15
  • [29] Nonrigid 2D Registration of fluoroscopic Coronary Artery image sequence with layered motion
    Park, Taewoo
    Jung, Hoyup
    Yun, Il Dong
    MEDICAL IMAGING 2016-BIOMEDICAL APPLICATIONS IN MOLECULAR, STRUCTURAL, AND FUNCTIONAL IMAGING, 2016, 9788
  • [30] A comparison of prospective and retrospective respiratory navigator gating in 3D MR coronary angiography - Editorial comment
    Bunce, NH
    Jhooti, P
    Underwood, SR
    Pennell, DJ
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2001, 17 (04): : 295 - 296