Design of filter to reject motion artifact of pulse oximetry

被引:41
|
作者
Lee, J
Jung, W
Kang, I
Kim, Y
Lee, G
机构
[1] Gyeongsang Natl Univ, Dept Elect Engn, Bioelect Lab, Kyungnam 660701, Gyeongsangnamdo, South Korea
[2] YONAM Coll Engn, Dept Comp & Informat Technol, Jinju 660750, Kyungnam, South Korea
关键词
oxygen saturation; biomedical signal processing; motion artifact filter;
D O I
10.1016/s0920-5489(03)00077-1
中图分类号
TP3 [计算技术、计算机技术];
学科分类号
0812 ;
摘要
The performance of the pulse oximeter, an instrument which non-invasively measures oxygen saturation in blood, is influenced by a patient's respiration or movement. Generally, the frequency band of the motion artifact signal generated from the patient's movement is overlapped with that of the patient's pulse wave which is measured by the received light sensor. Accordingly, it is difficult to filter the motion artifact of the pulse wave by using a filter which has a cut-off frequency that is fixed. In this study, the motion artifact is removed using the filter bank and the matched filter. Compared with traditional adaptive filter methods, the ratio variation is 50% lower than that of the moving average filter, allowing more stable measurement of oxygen saturation despite the patient's movement. (C) 2003 Elsevier B.V. All rights reserved.
引用
收藏
页码:241 / 249
页数:9
相关论文
共 50 条
  • [21] Effect of limbs' motion on pulse oximetry in preterm infants
    Marchionni, Paolo
    Scalise, Lorenzo
    Palazzi, Maria Laura
    Ercoli, Ilaria
    Carnielli, Virgilio Paolo
    2016 IEEE INTERNATIONAL SYMPOSIUM ON MEDICAL MEASUREMENTS AND APPLICATIONS (MEMEA), 2016, : 505 - 510
  • [22] A characterization of motion affecting pulse oximetry in 350 patients
    Tobin, RM
    Pologe, JA
    Batchelder, PB
    ANESTHESIA AND ANALGESIA, 2002, 94 (01): : S54 - S61
  • [23] The Effect of Motion on Pulse Oximetry and Its Clinical Significance
    Petterson, Michael T.
    Begnoche, Valerie L.
    Graybeal, John M.
    ANESTHESIA AND ANALGESIA, 2007, 105 : S78 - S84
  • [24] Towards Spectral Pulse Oximetry independent of motion artifacts
    Von Chong, Alejandro
    Terosiet, Mehdi
    Histace, Aymeric
    Romain, Olivier
    2018 21ST EUROMICRO CONFERENCE ON DIGITAL SYSTEM DESIGN (DSD 2018), 2018, : 479 - 483
  • [25] EVALUATION OF ARTIFACT DETECTION IN PULSE OXIMETRY SIGNALS USING A NEURAL-NETWORK
    EGBERT, TP
    WESTENSKOW, DR
    ORR, JA
    ANESTHESIOLOGY, 1993, 79 (3A) : A529 - A529
  • [26] Real-time pulse oximetry artifact annotation on computerized anaesthetic records
    Gostt R.K.
    Rathbone G.D.
    Tucker A.P.
    Journal of Clinical Monitoring and Computing, 2002, 17 (3-4) : 249 - 257
  • [27] Design and Evaluation of a New Sonification for Pulse Oximetry
    Sanderson, Penelope
    Paterson, Estrella
    Paterson, Neil
    ANESTHESIA AND ANALGESIA, 2016, 122
  • [28] Design and Development of a portable Pulse Oximetry system
    Zaltum, Mohamed A.
    Ahmad, M. Shukri
    Joret, Ariffuddin
    Jamil, M. Mahadi Abdul
    INTERNATIONAL JOURNAL OF INTEGRATED ENGINEERING, 2010, 2 (03): : 37 - 43
  • [29] Design and validation of pulse oximetry for low saturation
    Mannheimer, PD
    ANESTHESIA AND ANALGESIA, 2002, 94 (01): : S21 - S25